SearcharxivSearch

arXiv subjects

Steven Allen

Publications and source records attributed to Steven Allen.

15 recordsLinked to original sources

Advancing X-Ray Camera Front-End Electronics Architecture through the AXIS-TAP Technology Platform

Advancing time-domain soft X-ray astronomy demands focal plane readout electronics capable of high-speed digitization with low noise while maintaining spectral fidelity across multiple detector channels. The Advanced X-ray Imaging Satellite (AXIS), a NASA Probe-class mission concept, provided the driving requirements and heritage for developing a generalized high-speed (>=5 fps) camera Front-End Electronics (FEE) architecture applicable to future soft X-ray missions. The FEE architecture defines a modular, dual-box redundant configuration to operate a focal plane of four 16-channel CCDs, with functional partitioning for power distribution, thermal management, mechanism control, and image data acquisition and transmission to the spacecraft. To validate the core signal chain architecture, particularly the analog-to-digital conversion, FPGA-based processing, and Ethernet data transmission, a dedicated technology demonstrator, AXIS-TAP (ADC Testing and Acquisition Platform), has been designed and is currently in fabrication. AXIS-TAP employs commercial equivalents of radiation-tolerant components (FPGA, ADCs, Ethernet PHY) and interfaces directly with the STA Archon benchtop readout system, enabling simultaneous image acquisition from both systems to validate that the flight-like architecture achieves equivalent or superior noise performance. This paper presents the FEE architectural framework, the AXIS-TAP demonstrator design, and the design principles that enable scalability to future soft X-ray missions with similar detector requirements. Performance validation results will be reported upon completion of AXIS-TAP system integration and testing.

astro-ph.IM

First results for second generation SiSeRO CCD devices

The Astro2020 Decadal recommended the development of a suite of next generation astronomical observatories spanning the X-ray to near-IR spectrum. These programs require fast, extremely low noise detectors to fulfill their science goals. To address this technology gap, Stanford X-ray Astronomy and Observational Cosmology (XOC) group, MIT Lincoln Laboratory (MIT-LL), and MIT Kavli Institute (MKI) are advancing Single electron Sensitive Read Out (SiSeRO), a multiband detector technology capable of achieving substantially sub-electron noise via Repetitive Non-Destructive Readout (RNDR). We present initial results for our second generation SiSeRO CCDs. We also discuss our test bed, including a readout electronics system capable of accommodating all second-generation SiSeRO CCD variants utilizing the XOC-designed Multi-Channel Readout Chip (MCRC) ASIC.

astro-ph.IM

The QPO in REJ1034+396 originates in the hot corona

REJ1034+396 is one of the few active galactic nuclei with a significant quasi-periodic oscillation (QPO). The QPO has been observed in over 1 Ms of XMM-Newton observations spanning over a decade. We investigate the power spectral density function (PSD) of 7 long (~90 ks) XMM-Newton observations of the active galactic nucleus REJ1034+396 in two energy bands. The soft (0.3-0.5 keV) band targets emission from the disk, while the hard (2-7 keV) band isolates the primary X-ray continuum emission from the corona. The QPO is significantly detected in the hard band of 5 of the 7 observations. The best fitting models indicate that the QPO detection in both bands is entirely attributable to the coronal emission with no additional contribution from the disk. This explains the strong coherence between the hard and soft bands at the QPO frequency. The covariance spectrum is consistent with this picture as the variability at QPO frequencies is attributed solely to fluctuations in the hot corona. The time lag as a function of energy is well described by a ~2000 s intrinsic soft lag, resulting from the disk responding to emission from the corona, that undergoes phase wrapping at approximately the QPO frequency. By demonstrating that in this system the QPO arises in the corona, we provide new insights into the mechanisms generating QPOs.

astro-ph.HE

Using the XMM-Newton small window mode to investigate systematic uncertainties in the particle background of X-ray charge-coupled device detectors

The level and uncertainty of the particle induced background in CCD detectors plays a crucial role for future X-ray instruments, such as the Wide Field Imager (WFI) onboard Athena. To mitigate the background systematic uncertainties, which will limit the Athena science goals, we aim to understand the relationship between the energetic charged particles interacting in the detector and satellite, and the instrumental science background to an unprecedented level. These particles produce easily identified "cosmic-ray tracks" along with less easily identified signals produced by secondary particles, e.g., X-rays generated by particle interactions with the instrument and indistinguishable from genuine sky X-rays. We utilize the Small Window Mode of the PN camera onboard XMM-Newton to understand the time, spatial and energy dependence of the various background components, particularly the particle induced background. While the distribution of particle events follows expected detector readout patterns, we find a particle track length distribution inconsistent with the simple, isotropic model. We also find that the detector mode-specific readout results in a shifted Cu fluorescent line. We illustrate that on long timescales the variability of the particle background correlates well with the solar cycle. This 20-year lightcurve, can be reproduced by a particle detector onboard Chandra, the HRC anti-coincidence shield. We conclude that the self-anti-coincidence method of removing X-ray-like events near detected particle tracks in the same frame can be optimized with the inclusion of additional information, such as the energy of the X-ray. The results presented here are relevant for any future pixelated X-ray imaging detector, and could allow the WFI to probe to truly faint X-ray surface brightness.

astro-ph.IM

Directly Imaging the Cooling Flow in the Phoenix Cluster

In the centers of many galaxy clusters, the hot ($\sim$10$^7$ K) intracluster medium (ICM) can become dense enough that it should cool on short timescales. However, the low measured star formation rates in massive central galaxies and absence of soft X-ray lines from cooling gas suggest that most of this gas never cools - this is known as the "cooling flow problem." The latest observations suggest that black hole jets are maintaining the vast majority of gas at high temperatures. A cooling flow has yet to be fully mapped through all gas phases in any galaxy cluster. Here, we present new observations of the Phoenix cluster using the James Webb Space Telescope to map the [Ne VI] $\lambda$7.652$\mu$m emission line, allowing us to probe gas at 10$^{5.5}$ K on large scales. These data show extended [Ne VI] emission cospatial with (i) the cooling peak in the ICM, (ii) the coolest gas phases, and (iii) sites of active star formation. Taken together, these imply a recent episode of rapid cooling, causing a short-lived spike in the cooling rate which we estimate to be 5,000-23,000 M$_\odot$ yr$^{-1}$. These data provide the first large-scale map of gas at temperatures between 10$^5$-10$^6$ K in a cluster core, and highlight the critical role that black hole feedback plays in not only regulating but also promoting cooling.

astro-ph.GA

Cold Gas and Star Formation in the Phoenix Cluster with JWST

We present integral field unit observations of the Phoenix Cluster with the JWST Mid-infrared Instrument's Medium Resolution Spectrometer (MIRI/MRS). We focus this study on the molecular gas, dust, and star formation in the brightest cluster galaxy (BCG). We use precise spectral modeling to produce maps of the silicate dust, molecular gas, and polycyclic aromatic hydrocarbons (PAHs) in the inner $\sim$50 kpc of the cluster. We measure the optical depth from silicates by comparing the observed H$_2$ line ratios to those predicted by excitation models. We provide updated measurements of the total molecular gas mass of $1.9^{+0.5}_{-0.4} \times 10^{10}$ $M_{\odot}$ which agrees with CO-based estimates, providing an estimate of the CO-to-H$_2$ conversion factor of $\alpha_{\rm CO} = 0.8 \pm 0.2\,M_{\odot}\,{\rm pc}^{-2}\,({\rm K}\,{\rm km}\,{\rm s}^{-1})^{-1}$; an updated stellar mass of $M_* = 2.6 \pm 0.5 \times 10^{10}$ $M_\odot$; and star formation rates averaged over 10 and 100 Myr of $\langle{\rm SFR}\rangle_{\rm 10} = 1340 \pm 100$ $M_\odot\,{\rm yr}^{-1}$, and $\langle{\rm SFR}\rangle_{\rm 100} = 740 \pm 80$ $M_\odot\,{\rm yr}^{-1}$, respectively. The H$_2$ emission seems to be powered predominantly by shocks and star formation within the central $\sim 20$ kpc, induced by stellar feedback and radio jets from the active galactic nucleus. Additionally, we find nearly an order of magnitude drop in the star formation rates estimated by PAH fluxes in cool core BCGs compared to field galaxies, suggesting that hot particles from the intracluster medium are destroying PAH grains even in the centralmost 10s of kpc.

astro-ph.GA

An Exceptionally Powerful, Radiatively Driven Ultrafast Outflow in the Rapidly Accreting AGN REJ1034+396

We report the analysis of ~1Ms of XMM-Newton observations of the rapidly accreting active galactic nucleus REJ1034+396. The 0.3-9 keV EPIC-pn spectra are well described by a model consisting of steep continuum emission from the corona accompanied by relativistically-blurred reflection from a highly ionized accretion disk. The source is known to exhibit strong excess soft X-ray emission, which we show is well represented by thermal disk photons Comptonized by a warm plasma spanning the inner accretion flow. Additionally, the EPIC-pn data provide compelling evidence ($\Delta C\sim60$ for 4 additional parameters) for the presence of an ultrafast outflow (UFO) with a line-of-sight velocity $v/c=0.307^{+0.001}_{-0.005}$, and an emission signature consistent with reflection of the corona from modestly ionized, outflowing gas. The simultaneous $0.5-2.5$\,keV RGS spectra show clear absorption lines. Modelling of these data confirms the presence of the UFO and constrains its equivalent hydrogen column density, log $N_\mathrm{H}/$(atom cm$^{-2}$) = $21.7^{+0.1}_{-0.2}$. The RGS data also reveal at least two warm absorber components with a modest outflow velocity ($1680^{+40}_{-50}$ km/s). The measured properties and time evolution of the UFO in REJ1034+396 suggest that it is formed from collisionally ionized plasma, launched from the disk surface and accelerated by radiation pressure. The high terminal velocity and substantial absorbing column density imply that the outflow carries sufficient momentum and energy to transform its environment, being capable of driving out essentially all dust and gas it interacts with along the line of sight, even if the AGN were initially surrounded by a Compton thick absorber.

astro-ph.HE

Advancing Precision Particle Background Estimation for Future X-ray Missions: Correlated Variability between AMS and Chandra/XMM-Newton

Galactic cosmic ray (GCR) particles have a significant impact on the particle-induced background of X-ray observatories, and their flux exhibits substantial temporal variability, potentially influencing background levels. In this study, we present one-day binned high-energy reject rates derived from the Chandra-ACIS and XMM-Newton EPIC-pn instruments, serving as proxies for GCR particle flux. We systematically analyze the ACIS and EPIC-pn reject rates and compare them with the AMS proton flux. Our analysis initially reveals robust correlations between the AMS proton flux and the ACIS/EPIC-pn reject rates when binned over 27-day intervals. However, a closer examination reveals substantial fluctuations within each 27-day bin, indicating shorter-term variability. Upon daily binning, we observe finer. temporal structures in the datasets, demonstrating the presence of recurrent variations with periods of $\sim$ 25 days and 23 days in ACIS and EPIC-pn reject rates, respectively, spanning the years 2014 to 2018. Notably, during the 2016--2017 period, we additionally detect periodicities of $\sim$13.5 days and 9 days in the ACIS and EPIC-pn reject rates, respectively. Intriguingly, we observe a time lag of $\sim$ 6 days between the AMS proton flux and the ACIS/EPIC-pn reject rates during the second half of 2016. This time lag is not visible before 2016 and aftern2017. The underlying physical mechanisms responsible for this time lag remain a subject of ongoing investigation.

astro-ph.HE

Towards precision particle background estimation for future X-ray missions: correlated variability between Chandra ACIS and AMS

A science goal of many future X-ray observatories is mapping the cosmic web through deep exposures of faint diffuse sources. Such observations require low background and the best possible knowledge of the remaining unrejected background. The dominant contribution to the background above 1-2 keV is from Galactic Cosmic Ray protons. Their flux and spectrum are modulated by the solar cycle but also by solar activity on shorter timescales. Understanding this variability may prove crucial to reducing background uncertainty for ESA's Athena X-ray Observatory and other missions with large collecting area. We examine of the variability of the particle background as measured by ACIS on the Chandra X-ray Observatory and compare that variability to that measured by the Alpha Magnetic Spectrometer (AMS), a precision particle detector on the ISS. We show that cosmic ray proton variability measured by AMS is well matched to the ACIS background and can be used to estimate proton energies responsible for the background. We discuss how this can inform future missions.

astro-ph.IM

Mitigating the effects of particle background on the Athena Wide-Field Imager

The Wide Field Imager (WFI) flying on Athena will usher in the next era of studying the hot and energetic Universe. WFI observations of faint, diffuse sources will be limited by uncertainty in the background produced by high-energy particles. These particles produce easily identified "cosmic-ray tracks" along with signals from secondary photons and electrons generated by particle interactions with the instrument. The signal from these secondaries is identical to the X-rays focused by the optics, and cannot be filtered without also eliminating these precious photons. As part of a larger effort to understand the WFI background, we here present results from a study of background-reduction techniques that exploit the spatial correlation between cosmic-ray particle tracks and secondary events. We use Geant4 simulations to generate a realistic particle background, sort this into simulated WFI frames, and process those frames in a similar way to the expected flight and ground software to produce a WFI observation containing only particle background. The technique under study, Self Anti-Coincidence or SAC, then selectively filters regions of the detector around particle tracks, turning the WFI into its own anti-coincidence detector. We show that SAC is effective at improving the systematic uncertainty for observations of faint, diffuse sources, but at the cost of statistical uncertainty due to a reduction in signal. If sufficient pixel pulse-height information is telemetered to the ground for each frame, then this technique can be applied selectively based on the science goals, providing flexibility without affecting the data quality for other science. The results presented here are relevant for any future silicon-based pixelated X-ray imaging detector, and could allow the WFI and similar instruments to probe to truly faint X-ray surface brightness.

astro-ph.IM

Tiny-box: A tool for the versatile development and characterization of low noise fast X-ray imaging detectors

X-ray Charge Coupled Devices (CCDs) have been the workhorse for soft X-ray astronomical instruments for the past quarter century. They provide broad energy response, extremely low electronic read noise, and good energy resolution in soft X-rays. These properties, along with the large arrays and small pixel sizes available with modern-day CCDs, make them a potential candidate for next generation astronomical X-ray missions equipped with large collecting areas, high angular resolutions and wide fields of view, enabling observation of the faint, diffuse and high redshift X-ray universe. However, such high collecting area (about 30 times Chandra) requires these detectors to have an order of magnitude faster readout than current CCDs to avoid saturation and pile up effects. In this context, Stanford University and MIT have initiated the development of fast readout X-ray cameras. As a tool for this development, we have designed a fast readout, low noise electronics board (intended to work at a 5 Megapixel per second data rate) coupled with an STA Archon controller to readout a 512 x 512 CCD (from MIT Lincoln Laboratory). This versatile setup allows us to study a number of parameters and operation conditions including the option for digital shaping. In this paper, we describe the characterization test stand, the concept and development of the readout electronics, and simulation results. We also report the first measurements of read noise, energy resolution and other parameters from this set up. While this is very much a prototype, we plan to use larger, multi-node CCD devices in the future with dedicated ASIC readout systems to enable faster, parallel readout of the CCDs.

astro-ph.IM

Reducing the Athena WFI charged particle background: Results from Geant4 simulations

One of the science goals of the Wide Field Imager (WFI) on ESA's Athena X-ray observatory is to map hot gas structures in the universe, such as clusters and groups of galaxies and the intergalactic medium. These deep observations of faint diffuse sources require low background and the best possible knowledge of that background. The WFI Background Working Group is approaching this problem from a variety of directions. Here we present analysis of Geant4 simulations of cosmic ray particles interacting with the structures aboard Athena, producing signal in the WFI. We search for phenomenological correlations between these particle tracks and detected events that would otherwise be categorized as X-rays, and explore ways to exploit these correlations to flag or reject such events in ground processing. In addition to reducing the Athena WFI instrumental background, these results are applicable to understanding the particle component in any silicon-based X-ray detector in space.

astro-ph.IM

Characterisation of the Particle-Induced Background of XMM-Newton EPIC-pn: Short and Long Term Variability

The particle-induced background of X-ray observatories is produced by Galactic Cosmic Ray (GCR) primary protons, electrons, and He ions. Events due to direct interaction with the detector are usually removed by on board processing. The interactions of these primary particles with the detector environment produce secondary particles that mimic X-ray events from celestial sources and are much more difficult to identify. The filter wheel closed data from the XMM-Newton EPIC-pn camera in small window mode (SWM) contains both the X-ray-like background events and the events due to direct interactions with the primary particles. From this data we demonstrate that X-ray-like background events are spatially correlated with the primary particle interaction. This result can be used to further characterise and reduce the non-X-ray background in silicon-based X-ray detectors in current and future missions. We also show that spectrum and pattern fractions of secondary particle events are different from those produced by cosmic X-rays.

astro-ph.HE

The Athena WFI Science Products Module

The Science Products Module (SPM), a US contribution to the Athena Wide Field Imager, is a highly capable secondary CPU that performs special processing on the science data stream. The SPM will have access to both accepted X-ray events and those that were rejected by the on-board event recognition processing. It will include two software modules. The Transient Analysis Module will perform on-board processing of the science images to identify and characterize variability of the prime target and/or detection of serendipitous transient X-ray sources in the field of view. The Background Analysis Module will perform more sophisticated flagging of potential background events as well as improved background characterization, making use of data that are not telemetered to the ground, to provide improved background maps and spectra. We present the preliminary design of the SPM hardware as well as a brief overview of the software algorithms under development.

astro-ph.IM

Towards the 2020 vision of the baryon content of galaxy groups and clusters

Groups and clusters of galaxies occupy a special position in the hierarchy of large-scale cosmic structures because they are the largest and the most massive (from ~10^13 Msun to over 10^15 Msun) objects in the universe that have had time to undergo gravitational collapse. The large masses of clusters imply that their contents have been accreted from regions of ~8-40 comoving Mpc in size and should thus be representative of the mean matter content of the universe. During the next decade sensitive multi-wavelength observations should be able to map the radial distributions of all main mass components (stars, cold, warm, and hot gas and total mass) at z<~ 1 out to the virial radius. At the same time, comparative studies of real and simulated cluster samples sould allow us to use clusters as veritable astrophysical laboratories for studying galaxy formation, as well as testing our theoretical models of structure formation and underlying assumptions about fundamental physics governing the universe.

astro-ph.CO