SearcharxivSearch

arXiv subjects

Subrat Kumar Pradhan

Publications and source records attributed to Subrat Kumar Pradhan.

2 recordsLinked to original sources

In-Substrate Imaging of Diamond hBN FET Current via Widefield Quantum Diamond Microscopy

We demonstrate widefield magnetic imaging of current flow in hydrogen terminated diamond field effect transistors (FETs) through in-substrate nitrogen vacancy (NV) centers. Hydrogen termination of the diamond surface induces a two dimensional hole gas (2DHG), while an ensemble of near surface NV centers located $ \sim 1~\mu m$ below the surface enables noninvasive magnetic imaging of current flow with micrometer scale spatial resolution. The FETs were electrically characterized over a range of drain source biases $V_{ds}= 0$ to $-15V$ and gate voltages,$V_{gs}= +3$ to $-9V$ followed by in situ widefield NV magnetometry during device operation. Magnetic field maps and reconstructed current density distributions directly visualize current injection at the source drain contacts and transport beneath the hBN gated channel. Magnetic field maps reveal current density variations in the channel region owing to non-uniformities or defects in the gate dielectric. In addition, we observe a pronounced enhancement of the drain current ($\sim 600-900 \mu A$) and a shift in the apparent threshold voltage during laser illumination, reflecting photo induced changes in channel electrostatics. By correlating gate dependent magnetic images with simultaneous electrical measurements, we directly link spatial current distributions to FET transfer characteristics, providing new insight into buried interface transport and non-uniform gating effects in the transistor channel. As the methodology is compatible with top gated FETs, it can be used to map channel current distributions with micrometer resolution in emerging channel materials, such as 2D materials and wide bandgap channels, and establish widefield NV magnetometry as a powerful platform for probing charge transport in transistors and Van der Waals dielectric heterostructures.

cond-mat.mes-hall

Low cost passive pH sensor fabricated on scotch tape

We report the fabrication and characterization results of a simple and low-cost pH sensor fabricated using a graphite pencil to define a working electrode and silver paste to define a reference electrode on scotch tape. The sensor operation is based on potentiometric measurement and thereby insensitive to fabrication variations in shape of the electrode unlike amperometric and chemiresistive measurement techniques. The substrate of the disposable sensor is prepared by pasting scotch tape atop a piece of chart paper, and two types of sensors fabricated with 6B and 2B graphite pencils are tested with three solutions with different pH values. The sensor functions as a passive sensing tag without requiring any external power or stimulus, and the measured sensitivities of the pH sensors fabricated using 2B and 6B pencil carbon electrodes (PCEs) are $-4.54mV/pH$ and $-4.09mV/pH$ respectively.

physics.app-ph