Sune N. Jespersen

Publications and source records attributed to Sune N. Jespersen.

11 recordsLinked to original sources

MP-PCA denoising of fMRI time-series data can lead to artificial activation "spreading"

MP-PCA denoising has become the method of choice for denoising in MRI since it provides an objective threshold to separate the desired signal from unwanted thermal noise components. In rodents, thermal noise in the coils is an important source of noise that can reduce the accuracy of activation mapping in fMRI. Further confounding this problem, vendor data often contains zero-filling and other effects that may violate MP-PCA assumptions. Here, we develop an approach to denoise vendor data and assess activation "spreading" caused by MP-PCA denoising in rodent task-based fMRI data. Data was obtained from N = 3 mice using conventional multislice and ultrafast acquisitions (1 s and 50 ms temporal resolution, respectively), during visual stimulation. MP-PCA denoising produced SNR gains of 64% and 39% and Fourier spectral amplitude (FSA) increases in BOLD maps of 9% and 7% for multislice and ultrafast data, respectively, when using a small [2 2] denoising window. Larger windows provided higher SNR and FSA gains with increased spatial extent of activation that may or may not represent real activation. Simulations showed that MP-PCA denoising causes activation "spreading" with an increase in false positive rate and smoother functional maps due to local "bleeding" of principal components, and that the optimal denoising window for improved specificity of functional mapping, based on Dice score calculations, depends on the data's tSNR and functional CNR. This "spreading" effect applies also to another recently proposed low-rank denoising method (NORDIC). Our results bode well for dramatically enhancing spatial and/or temporal resolution in future fMRI work, while taking into account the sensitivity/specificity trade-offs of low-rank denoising methods.

physics.med-ph

Tensor denoising of high-dimensional MRI data

The signal to noise ratio (SNR) fundamentally limits the information accessible by magnetic resonance imaging (MRI). This limitation has been addressed by a host of denoising techniques, recently including so-called MPPCA: Principal component analysis (PCA) of the signal followed by automated rank estimation, exploiting the Marchenko-Pastur (MP) distribution of noise singular values. Operating on matrices comprised by data-patches, this popular approach objectively identifies noise components and, ideally, allows noise to be removed without introducing artifacts such as image blurring or non-local averaging. The MPPCA rank estimation, however, relies on a large number of noise singular values relative to the number of signal components to avoid such ill effects. This condition is unlikely to be met when data-patches and therefore matrices are small, for example due to spatially varying noise. Here, we introduce tensor MPPCA (tMPPCA) for the purpose of denoising multidimensional data, for example from multi-contrast acquisitions. Rather than combining dimensions in matrices, tMPPCA utilizes each dimension of the multidimensional data's inherent tensor-structure to better characterize noise, and to recursively estimate signal components. Relative to matrix-based MPPCA, tMPPCA requires no additional assumptions, and comparing the two in a numerical phantom and a multi-TE diffusion MRI dataset, tMPPCA dramatically improves denoising performance. This is particularly true for small data-patches, which we believe will improve denoising in cases of spatially varying noise.

physics.med-ph

Diffusion time dependence, power-law scaling, and exchange in gray matter

Diffusion MRI (dMRI) provides contrast that reflect diffusing spins' interactions with microstructural features of biological systems, but its specificity remains limited due to the ambiguity of its relation to the underlying microstructure. To improve specificity, biophysical models of white matter (WM) typically express dMRI signals according to the Standard Model (SM) and have more recently in gray matter (GM) attempted to incorporate cell soma (the SANDI model). The validity of the assumptions underlying these models, however, remains largely undetermined, especially in GM. Observing the models' unique, functional properties, such as the $b^{-1/2}$ power-law associated with 1d diffusion, has emerged as a fruitful strategy for experimental validation. The absence of this signature in GM has been explained by neurite water exchange, non-linear morphology, and/or obscuring soma signal contributions. Here, we present simulations in realistic neurons demonstrating that curvature and branching does not destroy the stick power-law in impermeable neurites, but that their signal is drowned by the soma under typical experimental conditions: Nevertheless, we identify an attainable experimental regime in which the neurite signal dominates. Furthermore, we find that exchange-driven time dependence produces a behavior opposite to that expected from restricted diffusion, thereby providing a functional signature disambiguating the two effects. We present data from dMRI experiments in ex vivo rat brain at ultrahigh field and observe a time dependence consistent with substantial exchange and a GM stick power-law. The first finding suggests significant water exchange while the second suggests a small sub-population of impermeable neurites. To quantify our observations, we harness the Kärger exchange model and incorporate the corresponding signal time dependence in SM and SANDI.

physics.med-ph

Double diffusion encoding and applications for biomedical imaging

Diffusion Magnetic Resonance Imaging (dMRI) is one of the most important contemporary non-invasive modalities for probing tissue structure at the microscopic scale. The majority of dMRI techniques employ standard single diffusion encoding (SDE) measurements, covering different sequence parameter ranges depending on the complexity of the method. Although many signal representations and biophysical models have been proposed for SDE data, they are intrinsically limited by a lack of specificity. Advanced dMRI methods have been proposed to provide additional microstructural information beyond what can be inferred from SDE. These enhanced contrasts can play important roles in characterizing biological tissues, for instance upon diseases (e.g. neurodegenerative, cancer, stroke), aging, learning, and development. In this review we focus on double diffusion encoding (DDE), which stands out among other advanced acquisitions for its versatility, ability to probe more specific diffusion correlations, and feasibility for preclinical and clinical applications. Various DDE methodologies have been employed to probe compartment sizes (Section 3), decouple the effects of microscopic diffusion anisotropy from orientation dispersion (Section 4), probe displacement correlations, study exchange, or suppress fast diffusing compartments (Section 6). DDE measurements can also be used to improve the robustness of biophysical models (Section 5) and study intra-cellular diffusion via magnetic resonance spectroscopy of metabolites (Section 7). This review discusses all these topics as well as important practical aspects related to the implementation and contrast in preclinical and clinical settings (Section 9) and aims to provide the readers a guide for deciding on the right DDE acquisition for their specific application.

physics.med-ph

The impact of realistic axonal shape on axon diameter estimation using diffusion MRI

To study axonal microstructure with diffusion MRI, axons are typically modeled as straight impermeable cylinders, whereby the transverse diffusion MRI signal can be made sensitive to the cylinder's inner diameter. However, the shape of a real axon varies along the axon direction, which couples the longitudinal and transverse diffusion of the overall axon direction. Here we develop a theory of the intra-axonal diffusion MRI signal based on coarse-graining of the axonal shape by 3d diffusion. We demonstrate how the estimate of the inner diameter is confounded by the diameter variations (beading), and by the local variations in direction (undulations) along the axon. We analytically relate diffusion MRI metrics, such as time-dependent radial diffusivity D(t) and kurtosis K(t), to the axonal shape, and validate our theory using Monte Carlo simulations in synthetic undulating axons with randomly positioned beads, and in realistic axons reconstructed from electron microscopy images of mouse brain white matter. We show that (i) In the narrow pulse limit, the inner diameter from D(t) is overestimated by about twofold due to a combination of axon caliber variations and undulations (each contributing a comparable effect size); (ii) The narrow-pulse kurtosis K$_{t\to\infty}$ deviates from that in an ideal cylinder due to caliber variations; we also numerically calculate the fourth-order cumulant for an ideal cylinder in the wide pulse limit, which is relevant for inner diameter overestimation; (iii) In the wide pulse limit, the axon diameter overestimation is mainly due to undulations at low diffusion weightings b; and (iv) The effect of undulations can be considerably reduced by directional averaging of high-b signals, with the apparent inner diameter given by a combination of the axon caliber (dominated by the thickest axons), caliber variations, and the residual contribution of undulations.

physics.med-ph

Optimal experimental design for biophysical modelling in multidimensional diffusion MRI

Computational models of biophysical tissue properties have been widely used in diffusion MRI (dMRI) research to elucidate the link between microstructural properties and MR signal formation. For brain tissue, the research community has developed the so-called Standard Model (SM) that has been widely used. However, in clinically applicable acquisition protocols, the inverse problem that recovers the SM parameters from a set of MR diffusion measurements using pairs of short pulsed field gradients was shown to be ill-posed. Multidimensional dMRI was shown to solve this problem by combining linear and planar tensor encoding data. Given sufficient measurements, multiple choices of b-tensor sets provide enough information to estimate all SM parameters. However, in the presence of noise, some sets will provide better results. In this work, we develop a framework for optimal experimental design of multidimensional dMRI sequences applicable to the SM. This framework is based on maximising the determinant of the Fisher information matrix, which is averaged over the full SM parameter space. This averaging provides a fairly objective information metric tailored for the expected signal but that only depends on the acquisition configuration. The optimisation of this metric can be further restricted to any subclass of desirable design constraints like, for instance, hardware-specific constraints. In this work, we compute the optimal acquisitions over the set of all b-tensors with fixed eigenvectors.

physics.med-ph

Evaluation of principal component analysis image denoising on multi-exponential MRI relaxometry

PURPOSE: Multi-exponential relaxometry is a powerful tool for characterizing tissue, but generally requires high image signal-to-noise ratio (SNR). This work evaluates the use of principal-component-analysis (PCA) denoising to mitigate these SNR demands and improve the precision of relaxometry measures. METHODS: PCA denoising was evaluated using both simulated and experimental MRI data. Bi-exponential transverse relaxation signals were simulated for a wide range of acquisition and sample parameters, and experimental data were acquired from three excised and fixed mouse brains. In both cases, standard relaxometry analysis was performed on both original and denoised image data, and resulting estimated signal parameters were compared. RESULTS: Denoising reduced the root-mean-square-error of parameters estimated from multi-exponential relaxometry by factors of 2 to 4x, for typical acquisition and sample parameters. Denoised images and subsequent parameter maps showed little or no signs of spatial artifact or loss of resolution. CONCLUSION: Experimental studies and simulations demonstrate that PCA denoising of MRI relaxometry data is an effective method of improving parameter precision without sacrificing image resolution. This simple yet important processing step thus paves the way for broader applicability of multi-exponential MRI relaxometry.

physics.med-ph

Accurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain

Microscopic diffusion anisotropy (μA) has been recently gaining increasing attention for its ability to decouple the average compartment anisotropy from orientation dispersion. Advanced diffusion MRI sequences, such as double diffusion encoding (DDE) and double oscillating diffusion encoding (DODE) have been used for mapping μA. However, the time-dependence of μA has not been investigated insofar, and furthermore, the accuracy of μA estimation vis-à-vis different b-values was not assessed. Here, we investigate both these concepts using theory, simulation, and experiments in the mouse brain. In the first part, simulations and experimental results show that the conventional estimation of microscopic anisotropy from the difference of D(O)DE sequences with parallel and orthogonal gradient directions yields values that highly depend on the choice of b-value. To mitigate this undesirable bias, we propose a multi-shell approach that harnesses a polynomial fit of the signal difference up to third order terms in b-value. In simulations, this approach yields more accurate μA metrics, which are similar to the ground truth values. The second part of this work uses the proposed multi-shell method to estimate the time/frequency dependence of μA. The data shows either an increase or no change in μA with frequency depending on the region of interest, both in white and gray matter. When comparing the experimental results with simulations, it emerges that simple geometric models such as infinite cylinders with either negligible or finite radii cannot replicate the measured trend, and more complex models, which, for example, incorporate structure along the fibre direction are required. Thus, measuring the time dependence of microscopic anisotropy can provide valuable information for characterizing tissue microstructure.

physics.med-ph

Double Diffusion Encoding Prevents Degeneracy in Parameter Estimation of Biophysical Models in Diffusion MRI

Purpose: Biophysical tissue models are increasingly used in the interpretation of diffusion MRI (dMRI) data, with the potential to provide specific biomarkers of brain microstructural changes. However, the general Standard Model has recently shown that model parameter estimation from dMRI data is ill-posed unless very strong magnetic gradients are used. We analyse this issue for the Neurite Orientation Dispersion and Density Imaging with Diffusivity Assessment (NODDIDA) model and demonstrate that its extension from Single Diffusion Encoding (SDE) to Double Diffusion Encoding (DDE) solves the ill-posedness and increases the accuracy of the parameter estimation. Methods: We analyse theoretically the cumulant expansion up to fourth order in b of SDE and DDE signals. Additionally, we perform in silico experiments to compare SDE and DDE capabilities under similar noise conditions. Results: We prove analytically that DDE provides invariant information non-accessible from SDE, which makes the NODDIDA parameter estimation injective. The in silico experiments show that DDE reduces the bias and mean square error of the estimation along the whole feasible region of 5D model parameter space. Conclusions: DDE adds additional information for estimating the model parameters, unexplored by SDE, which is enough to solve the degeneracy in the NODDIDA model parameter estimation.

physics.bio-ph

Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation

We review, systematize and discuss models of diffusion in neuronal tissue, by putting them into an overarching physical context of coarse-graining over an increasing diffusion length scale. From this perspective, we view research on quantifying brain microstructure as occurring along the three major avenues. The first avenue focusses on the transient, or time-dependent, effects in diffusion. These effects signify the gradual coarse-graining of tissue structure, which occurs qualitatively differently in different brain tissue compartments. We show that studying the transient effects has the potential to quantify the relevant length scales for neuronal tissue, such as the packing correlation length for neuronal fibers, the degree of neuronal beading, and compartment sizes. The second avenue corresponds to the long-time limit, when the observed signal can be approximated as a sum of multiple non-exchanging anisotropic Gaussian components. Here the challenge lies in parameter estimation and in resolving its hidden degeneracies. The third avenue employs multiple diffusion encoding techniques, able to access information not contained in the conventional diffusion propagator. We conclude with our outlook on the future directions which can open exciting possibilities for designing quantitative markers of tissue physiology and pathology, based on methods of studying mesoscopic transport in disordered systems.

physics.bio-ph

White matter biomarkers from fast protocols using axially symmetric diffusion kurtosis imaging

White matter tract integrity (WMTI) can characterize brain microstructure in areas with highly aligned fiber bundles. Several WMTI biomarkers have now been validated against microscopy and provided promising results in studies of brain development and aging, and in a number of brain disorders. Currently, WMTI is mostly used in dedicated animal studies and clinical studies of slowly progressing diseases but has not yet emerged as a routine clinical tool. To this end, a less data intensive experimental method would be beneficial by enabling high resolution validation studies, and ease clinical applications by speeding up data acquisition compared to typical diffusion kurtosis imaging (DKI) protocols utilized as part of WMTI imaging. Here, we evaluate WMTI based on recently introduced axially symmetric DKI which has lower data demand than conventional DKI. We compare WMTI parameters derived from conventional DKI to those calculated analytically from axially symmetric DKI. We employ numerical simulations, as well as data from fixed rat spinal cord (1) and in vivo human (3) and rat brain (4). Our analysis shows that analytical WMTI based on axially symmetric DKI with sparse data sets (19 images) produces WMTI metrics that correlate strongly with estimates based on traditional DKI data sets (60 images or more). We demonstrate the preclinical potential of the proposed WMTI technique in in vivo rat brain (300 μm isotropic resolution with whole brain coverage). WMTI parameter estimates are subject to a duality leading to two solution branches dependent on a sign choice which is currently debated. Results from both of these branches are presented and discussed throughout our analysis. The proposed fast WMTI approach may be useful for preclinical research and e.g. clinical evaluation of patients with traumatic white matter injuries or symptoms of neurovascular or neuroinflammatory disorders.

physics.med-ph