Searcharxiv⌕ Search

arXiv subjects

Sung Hyun Kim

Publications and source records attributed to Sung Hyun Kim.

8 recordsLinked to original sources

Probing the 3+1 neutrino model in the SHiP experiment

In this study, as an extension of our previous work, we estimate the sensitivity of the Search for Hidden Particles (SHiP) experiment to the 3+1 model using the charged-current deep inelastic scattering event spectrum. We employ the Feldman-Cousins method with a parametric bootstrap to account for nuisance parameters and systematic uncertainties. In the previous study, we proposed a dual baseline approach by suggesting Far SND (FSND) at 120 m with Near SND (NSND) at 27 m. We employ the same approach in this study. The NSND-only configuration can probe mixing parameters of $|U_{\alpha4}|^2 \gtrsim 0.1$ near $Δm_{41}^2 \sim 10^3\,\mathrm{eV}^2$, with a reduction of normalized systematic uncertainties from 20\% to 10\% improving sensitivity by roughly a factor of two. Moreover, the inclusion of FSND significantly enhances the sensitivity by a factor of 2 to 10 depending on the flavor and the systematic uncertainty. In two-flavor mixing scenarios, a cancellation between neutrino appearance and disappearance generates kinks in the sensitivity curves, that are vanished in the dual-baseline approach.

hep-ph↗

New Constraints on Axion-Like Particles with the NEON Detector at a Nuclear Reactor

We report new constraints on axion-like particles (ALPs) using data from the NEON experiment, which features a 16.7 kg of NaI(Tl) target located 23.7 meters from a 2.8 GW thermal power nuclear reactor. Analyzing a total exposure of 3063 kg$\cdot$days, with 1596 kg$\cdot$days during reactor-on and 1467 kg$\cdot$days during reactor-off periods, we compared energy spectra to search for ALP-induced signals. No significant signal was observed, enabling us to set exclusion limits at the 95\% confidence level. These limits probe previously unexplored regions of the ALP parameter space, particularly for axion mass ($m_a$) near $1$ MeV/c$^2$. For ALP-photon coupling (${g_{aγ}}$), limits reach as low as 6.24$\times$ 10$^{-6}$ GeV$^{-1}$ at $m_a$ = 3.0 MeV/c$^2$, while for ALP-electron coupling (${g_{ae}}$), limits reach 4.95$\times$ 10$^{-8}$ at $m_a$ = 1.02 MeV/c$^2$. This work demonstrates the potential for future reactor experiments to probe unexplored ALP parameter space.

hep-ex↗

Probing the mixing between sterile and tau neutrinos in the SHiP experiment

We study the expected sensitivity to the mixing between sterile and tau neutrinos directly from the tau neutrino disappearance in the high-energy fixed target experiment. Here, the beam energy is large enough to produce tau neutrinos at the target with large luminosity. During their propagation to the detector, tau neutrinos may oscillate into sterile neutrinos. By examining the energy spectrum of the observed tau neutrino events, we can probe the mixing between sterile and tau neutrinos directly. In this paper, we consider Scattering and Neutrino Detector (SND) at SHiP experiment as a showcase, which uses 400 GeV protons from SPS at CERN, and expect to observe 7,300 tau and anti-tau neutrinos from the $2\times 10^{20}$ POT for 5 years operation. Assuming the uncertainty of 10\%, we find the sensitivity $|U_{τ4}|^2 \sim 0.08$\, (90\% CL) for $Δm_{41}^2 \sim 500\ \mathrm{eV}^2$ with 10\% background to the signal. We also consider a far SND at the end of the SHiP Hidden Sector Decay Spectrometer (HSDS), in which case the sensitivity would be enhanced to $|U_{τ4}|^2 \sim 0.02$. Away from this mass, the sensitivity becomes lower than $|U_{τ4}|^2 \sim 0.15$ for $Δm_{41}^2 \lesssim 100\ \mathrm{eV}^2$ or $Δm_{41}^2\gtrsim 10^4 \mathrm{eV}^2$.

hep-ph↗

Performance of an ultra-pure NaI(Tl) detector produced by an indigenously-developed purification method and crystal growth for the COSINE-200 experiment

The COSINE-100 experiment has been operating with 106 kg of low-background NaI(Tl) detectors to test the results from the DAMA/LIBRA experiment, which claims to have observed dark matter. However, since the background of the NaI(Tl) crystals used in the COSINE-100 experiment is 2-3 times higher than that in the DAMA detectors, no conclusion regarding the claimed observation from the DAMA/LIBRA experiment could be reached. Therefore, we plan to upgrade the current COSINE-100 experiment to the next phase, COSINE-200, by using ultra-low background NaI(Tl) detectors. The basic principle was already proved with the commercially available Astro-grade NaI powder from Sigma-Aldrich company. However, we have developed a mass production process of ultra-pure NaI powder at the Center for Underground Physics (CUP) of the Institute for Basic Science (IBS), Korea, using the direct purification of the raw NaI powder. We plan to produce more than 1,000 kg of ultra-pure powder for the COSINE200 experiment. With our crystal grower installed at CUP, we have successfully grown a low-background crystal using our purification technique for the NaI powder. We have assembled a low-background NaI(Tl) detector. In this article, we report the performance of this ultra-pure NaI(Tl) crystal detector produced at IBS, Korea.

physics.ins-det↗

MEDS-Net: Self-Distilled Multi-Encoders Network with Bi-Direction Maximum Intensity projections for Lung Nodule Detection

In this study, we propose a lung nodule detection scheme which fully incorporates the clinic workflow of radiologists. Particularly, we exploit Bi-Directional Maximum intensity projection (MIP) images of various thicknesses (i.e., 3, 5 and 10mm) along with a 3D patch of CT scan, consisting of 10 adjacent slices to feed into self-distillation-based Multi-Encoders Network (MEDS-Net). The proposed architecture first condenses 3D patch input to three channels by using a dense block which consists of dense units which effectively examine the nodule presence from 2D axial slices. This condensed information, along with the forward and backward MIP images, is fed to three different encoders to learn the most meaningful representation, which is forwarded into the decoded block at various levels. At the decoder block, we employ a self-distillation mechanism by connecting the distillation block, which contains five lung nodule detectors. It helps to expedite the convergence and improves the learning ability of the proposed architecture. Finally, the proposed scheme reduces the false positives by complementing the main detector with auxiliary detectors. The proposed scheme has been rigorously evaluated on 888 scans of LUNA16 dataset and obtained a CPM score of 93.6\%. The results demonstrate that incorporating of bi-direction MIP images enables MEDS-Net to effectively distinguish nodules from surroundings which help to achieve the sensitivity of 91.5% and 92.8% with false positives rate of 0.25 and 0.5 per scan, respectively.

eess.IV↗

Dual-Stage Deeply Supervised Attention-based Convolutional Neural Networks for Mandibular Canal Segmentation in CBCT Scans

Accurate segmentation of mandibular canals in lower jaws is important in dental implantology. Medical experts determine the implant position and dimensions manually from 3D CT images to avoid damaging the mandibular nerve inside the canal. In this paper, we propose a novel dual-stage deep learning-based scheme for the automatic segmentation of the mandibular canal. Particularly, we first enhance the CBCT scans by employing the novel histogram-based dynamic windowing scheme, which improves the visibility of mandibular canals. After enhancement, we design 3D deeply supervised attention U-Net architecture for localizing the volumes of interest (VOIs), which contain the mandibular canals (i.e., left and right canals). Finally, we employed the multi-scale input residual U-Net architecture (MS-R-UNet) to segment the mandibular canals using VOIs accurately. The proposed method has been rigorously evaluated on 500 scans. The results demonstrate that our technique outperforms the current state-of-the-art segmentation performance and robustness methods.

eess.IV↗

Volumetric Lung Nodule Segmentation using Adaptive ROI with Multi-View Residual Learning

Accurate quantification of pulmonary nodules can greatly assist the early diagnosis of lung cancer, which can enhance patient survival possibilities. A number of nodule segmentation techniques have been proposed, however, all of the existing techniques rely on radiologist 3-D volume of interest (VOI) input or use the constant region of interest (ROI) and only investigate the presence of nodule voxels within the given VOI. Such approaches restrain the solutions to investigate the nodule presence outside the given VOI and also include the redundant structures into VOI, which may lead to inaccurate nodule segmentation. In this work, a novel semi-automated approach for 3-D segmentation of nodule in volumetric computerized tomography (CT) lung scans has been proposed. The proposed technique can be segregated into two stages, at the first stage, it takes a 2-D ROI containing the nodule as input and it performs patch-wise investigation along the axial axis with a novel adaptive ROI strategy. The adaptive ROI algorithm enables the solution to dynamically select the ROI for the surrounding slices to investigate the presence of nodule using deep residual U-Net architecture. The first stage provides the initial estimation of nodule which is further utilized to extract the VOI. At the second stage, the extracted VOI is further investigated along the coronal and sagittal axis with two different networks and finally, all the estimated masks are fed into the consensus module to produce the final volumetric segmentation of nodule. The proposed approach has been rigorously evaluated on the LIDC dataset, which is the largest publicly available dataset. The result suggests that the approach is significantly robust and accurate as compared to the previous state of the art techniques.

eess.IV↗

Laser-driven jetting of nanoscale non-conducting liquid droplets via hollow optical fiber

Along a single strand of micro-capillary optical waveguide, we achieved an efficient transfer of the light momentum onto the liquid contained there within, successfully atomizing it into nanoscale droplets. A hollow optical fiber (HOF), with a ring core and central air hole, was used to optically drive jetting of non-conducting transparent liquid of sub-pico liter volume, out of a surface-treated facet orifice, producing droplets ranging from nano to micrometer scale. These droplets were carried over the propagating light field forming a spherical cone, which were then deposited on a silica substrate in a Gaussian spatial distribution. The deposited patterns and sizes of individual droplets were characterized as a function of the laser power, irradiation time, and distance between the HOF and a substrate. This HOF based laser driven atomization technique obviates imperative electrode or aerial pressure requirements in prior methods, opening a new pathway to drastically scale down the form-factor of liquid jetting devices, and has a high potential to in-situ atomization and delivery of bio-medical non-conducting liquids in a microscopic environment, which was not possible in prior arts.

physics.app-ph↗