Searcharxiv⌕ Search

arXiv subjects

SungWoo Youn

Publications and source records attributed to SungWoo Youn.

28 records · Page 2Linked to original sources

First Results from Axion Haloscope at CAPP around 10.7 $μ$eV

The Center for Axion and Precision Physics research at the Institute for Basic Science is searching for axion dark matter using ultra-low temperature microwave resonators. We report the exclusion of the axion mass range 10.7126$-$10.7186 $μ$eV with near Kim-Shifman-Vainshtein-Zakharov (KSVZ) coupling sensitivity and the range 10.16$-$11.37 $μ$eV with about 9 times larger coupling at 90$\%$ confidence level. This is the first axion search result in these ranges. It is also the first with a resonator physical temperature of less than 40 mK.

hep-ex↗

Sensitivity improvement in hidden photon detection using resonant cavities

Analogous to the light-shining-through-wall setup proposed for axion-like particle searches, a pair of resonant cavities have been considered to search for an extra U(1) massive gauge boson, called a hidden photon, which mediates the interactions in the hidden sector. We propose a new cavity configuration, consisting of a cylindrical emitter surrounded by a hollow cylindrical detector to remarkably improve experimental sensitivity to hidden photon signals in the $μ$eV mass range. An extensive study was conducted to find the optimal cavity geometry and resonant mode, which yields the best performance. In addition, a feasible application of superconducting RF technology was explored. We found the integration of these potential improvements will enhance the sensitivity to the effective kinetic mixing parameter between the hidden photon and the Standard Model photon by multiple orders of magnitude.

hep-ex↗

Search for invisible axion dark matter with a multiple-cell haloscope

We present the first results of a search for invisible axion dark matter using a multiple-cell cavity haloscope. This cavity concept was proposed to provide a highly efficient approach to high mass regions compared to the conventional multiple-cavity design, with larger detection volume, simpler detector setup, and unique phase-matching mechanism. Searches with a double-cell cavity superseded previous reports for the axion-photon coupling over the mass range between 13.0 and 13.9$\,μ$eV. This result not only demonstrates the novelty of the cavity concept for high-mass axion searches, but also suggests it can make considerable contributions to the next-generation experiments.

hep-ex↗

Revisiting the detection rate for axion haloscopes

The cavity haloscope has been employed to detect microwave photons resonantly converted from invisible cosmic axions under a strong magnetic field. In this scheme, the axion-photon conversion power has been formulated to be valid for certain conditions, either $Q_{cavity}\ll Q_{\rm axion}$ or $Q_{cavity} \gg Q_{axion}$. This remedy, however, fails when these two quantities are comparable to each other. Furthermore, the noise power flow has been treated independently of the impedance mismatch of the system, which could give rise to misleading estimates of the experimental sensitivity. We revisit the analytical approaches to derive a general description of the signal and noise power. We also optimize the coupling strength of a receiver to yield the maximal sensitivity for axion search experiments.

hep-ex↗

Exploiting higher-order resonant modes for axion haloscopes

The haloscope is one of the most sensitive approaches to the QCD axion physics within the region where the axion is considered to be a dark matter candidate. Current experimental sensitivities, which rely on the lowest fundamental TM010 mode of a cylindrical cavity, are limited to relatively low mass regions. Exploiting higher-order resonant modes would be beneficial because it will enable us to extend the search range with no volume loss and higher quality factors. This approach has been discarded mainly because of the significant degradation of form factor, and difficulty with frequency tuning. Here we introduce a new tuning mechanism concept which both enhances the form factor and yields reasonable frequency tunability. A proof of concept demonstration verified that this design is feasible for high mass axion search experiments.

physics.ins-det↗

Axion Dark Matter Research with IBS/CAPP

The axion, a consequence of the PQ mechanism, has been considered as the most elegant solution to the strong-CP problem and a compelling candidate for cold dark matter. The Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) was established on 16 October 2013 with a main objective to launch state of the art axion experiments in South Korea. Relying on the haloscope technique, our strategy is to run several experiments in parallel to explore a wide range of axion masses with sensitivities better than the QCD axion models. We utilize not only the advanced technologies, such as high-field large-volume superconducting (SC) magnets, ultra low temperature dilution refrigerators, and nearly quantum-limited noise amplifiers, but also some unique features solely developed at the Center, including high-quality SC resonant cavities surviving high magnetic fields and efficient cavity geometries to reach high-frequency regions. Our goal is to probe axion dark matter in the frequency range of 1-10 GHz in the first phase and then ultimately up to 25 GHz, even in a scenario where axions constitute only 10% of the local dark matter halo. In this report, the current status and future prospects of the experiments and R&D activities at IBS/CAPP are described.

physics.ins-det↗

Comment on "Tunable Supermode Dielectric Resonators for Axion Dark-Matter Haloscopes"

We comment on a recently published paper, Phys. Rev. Applied 9, 014028 (2018), which presents frequency-tuning mechanisms for dielectric resonators and demonstrates their potential application to axion haloscopes. One of the schemes introduces a cylindrical dielectric hollow and splits it in the axial direction to tune the frequency. The authors claim that this scheme offers a 1 to 2-order-of-magnitude improvement in axion search sensitivity in exploiting a higher-order resonant mode. We find that their study is based on unrealistic cavity modeling and inappropriate choice of the figure of merit (FOM), which could mislead to the significant improvement in sensitivity. Considering a practical cavity structure and an appropriate FOM, we recalculate the significance of the scheme, which turns out to be not substantial.

physics.ins-det↗

Concept of multiple-cell cavity for axion dark matter search

In cavity-based axion dark matter search experiments exploring high mass regions, multiple-cavity design is considered to increase the detection volume within a given magnet bore. We introduce a new idea, referred to as multiple-cell cavity, which provides various benefits including a larger detection volume, simpler experimental setup, and easier phase-matching mechanism. We present the characteristics of this concept and demonstrate the experimental feasibility with an example of a double-cell cavity.

astro-ph.IM↗

Phase-matching of multiple-cavity detectors for dark matter axion search

Conventional axion dark matter search experiments employ cylindrical microwave cavities immersed in a solenoidal magnetic field. Exploring higher frequency regions requires smaller size cavities as the TM010 resonant frequencies scale inversely with cavity radius. One intuitive way to make efficient use of a given magnet volume, and thereby to increase the experimental sensitivity, is to bundle multiple cavities together and combine their individual outputs ensuring phase-matching of the coherent axion signal. We perform an extensive study for realistic design of a phase-matching mechanism for multiple-cavity systems and demonstrate its experimental feasibility using a double-cavity system.

astro-ph.IM↗

Measurement of the fraction of top quark pair events produced via gluon-gluon fusion at the Tevatron in lepton+jets final states

We report a measurement of the fraction of top quark pair events produced via gluon-gluon fusion in $p\bar{p}$ collisions at $\sqrt{s} = 1.96 ~\rm TeV$ in lepton+jets final states using the full RunII data set corresponding to $9.7 ~\rm fb^{-1}$ of integrated luminosity collected by the DØ experiment. We utilize a boosted decision tree to distinguish top quark pair events produced by $q\bar{q}$ annihilation and $gg$ fusion. We perform a template fit to extract the $t\bar{t}$ production fraction via $gg$ fusion and find $f_{gg} = 0.096 \pm 0.039 ~(\rm stat.) ~^{+0.077}_{-0.062} ~(\rm syst.)$.

hep-ex↗