SearcharxivSearch

arXiv subjects

Sunghoon Eom

Publications and source records attributed to Sunghoon Eom.

3 recordsLinked to original sources

Fully stabilized 25 GHz frequency comb for frequency calibration of optical spectrum analyzer

Optical spectrometers are widely used in scientific and industrial applications, and precise frequency calibration is essential for ensuring their reliable performance. Traditionally, spectrometers have been calibrated using reference gas cells or reference lamps. However, such conventional methods are not enough to meet the demands for high accuracy and stability. Although frequency-stabilized lasers offer excellent frequency uncertainty, they provide only a single calibration point at a fixed frequency, which is unsuitable for wide-range spectrometer calibration. In this work, we demonstrate a fully stabilized, high-repetition rate electro-optic frequency comb (EO comb) as an absolute frequency reference providing multiple calibration points over a broad spectral range. Our 25 GHz EO comb provides a broadband spectrum spanning from 189.5 THz to 196 THz (corresponding to 1530 nm to 1582 nm), traceable to a frequency standard with a relative standard uncertainty of 10^-13. The well-defined and evenly spaced comb modes can be spectrally resolved by conventional optical spectrometers, enabling wide-range, high-precision frequency calibration. We directly calibrated a commercial spectrometer by referencing its measured frequency values to our well-defined comb modes, thereby evaluating the frequency error with a standard uncertainty of 20 MHz (or relative standard uncertainty of 10^-7), which is limited by the Type A uncertainty (repeatability) of the spectrometer. The proposed method is simple to implement and provides multiple calibration points referenced to the frequency standards over a broad spectral range. This approach improves both the calibration and performance evaluation of spectrometers, and it contributes to the advancement of optical metrology.

physics.optics

Approaching the quantum-limited precision in frequency-comb-based spectral interferometry for length measurements

Over the last two decades, frequency combs have brought breakthroughs in length metrology with traceability to length standards. In particular, frequency-comb-based spectral interferometry is regarded as a promising technology for next-generation length standards. However, to achieve this, the nanometer-level precision inherent in laser interferometer is required. Here, we report distance measurements by a frequency-comb-based spectral interferometry with sub-nm precision close to a standard quantum limit. The measurement precision was confirmed as 0.67 nm at an averaging time of 25 us. The measurement sensitivity was found to be 4.5 10-12m/Hz1/2, close to the quantum-limit. As a practical example of observing precise physical phenomena, we demonstrated measurements of acoustic-wave-induced vibration and laser eavesdropping. Our study will be an important step toward the practical realization of upcoming length standards.

physics.optics

Programmable spectral shaping to improve the measurement precision of frequency comb mode-resolved spectral interferometric ranging

Comb-mode resolved spectral domain interferometry (CORE-SDI), which is capable of measuring length of kilometers or more with precision on the order of nanometers, is considered to be a promising technology for next-generation length standards, replacing laser displacement interferometers. In this study, we aim to improve the measurement precision of CORE-SDI using programmable spectral shaping. We report the generation of effectively broad and symmetric light sources through the programmable spectral shaping. The light source used here was generated by the spectrally-broadened electro-optic comb with a repetition rate of 17.5 GHz. Through the programmable spectral shaping, the optical spectrum was flattened within 1 dB, resulting in a square-shaped optical spectrum. As a result, the 3-dB spectral width was extended from 1.15 THz to 6.7 THz. We performed a comparison between the measurement results of various spectrum shapes. We confirmed an improvement in the measurement precision from 69 nm to 6 nm, which was also corroborated by numerical simulations. We believe that this study on enhancing the measurement precision of CORE-SDI through the proposed spectral shaping will make a significant contribution to reducing the measurement uncertainty of future CORE-SDI systems, thereby advancing the development of next-generation length standards.

physics.optics