Searcharxiv⌕ Search

arXiv subjects

Surajit Pal

Publications and source records attributed to Surajit Pal.

22 records · Page 2Linked to original sources

GAMMA: GAMma Multiplicity Filter Array for the selection of angular momentum in heavy ion collision reactions

A 50 element BaF2 gamma-multiplicity filter has been designed, fabricated and installed successfully at the Variable Energy Cyclotron Centre (VECC), Kolkata for angular momentum selection in heavy ion collision reactions. A thorough GEANT3 Monte Carlo simulation was performed to optimize the individual detector shape and geometrical structure of the array. The detectors have been fabricated in-house from bare barium fluoride crystals (each measuring 5 cm in length and having cross-sectional area of 3.5 x 3.5 cm2). The basic detector properties have been studied using the lab standard -ray sources. The response function of the filter has been studied using GEANT3 for mapping the fold distribution of the filter onto the angular momentum space. The multiplicity filter has been used successfully to measure the high angular momentum of the compound nuclei populated in the reaction 20Ne (E = 145 & 160 MeV) + 93Nb, 27Al as well as low angular momentum events from the fission fragments of 252Cf spontaneous fission source. The filter has also been used successfully for correcting non-statistical events involved in the heavy ion fusion reaction.

nucl-ex↗

Scaling of the giant dipole resonance widths in hot rotating nuclei from the ground state values

The systematics of the giant dipole resonance (GDR) widths in hot and rotating nuclei are studied in terms of temperature T, angular momentum J and mass A. The different experimental data in the temperature range of 1 - 2 MeV have been compared with the thermal shape fluctuation model (TSFM) in the liquid drop formalism using a modified approach to estimate the average values of T, J and A in the decay of the compound nucleus. The values of the ground state GDR widths have been extracted from the TSFM parametrization in the liquid drop limit for the corrected T, J and A for a given system and compared with the corresponding available systematics of the experimentally measured ground state GDR widths for a range of nuclei from A = 45 to 194. Amazingly, the nature of the theoretically extracted ground state GDR widths matches remarkably well, though 1.5 times smaller, with the experimentally measured ground state GDR widths consistently over a wide range of nuclei.

nucl-ex↗

Giant Dipole Resonance Width in near-Sn Nuclei at Low Temperature and High Angular Momentum

High energy gamma-rays in coincidence with low energy yrast gamma-rays have been measured from 113Sb, at excitation energies of 109 and 122 MeV, formed by bombarding 20Ne on 93Nb at projectile energies of 145 and 160 MeV respectively to study the role of angular momentum (J) and temperature (T) over Giant Dipole Resonance (GDR) width. The maximum populated angular momenta for fusion were 67hbar and 73hbar respectively for the above-mentioned beam energies. The high energy photons were detected using a Large Area Modular BaF2 Detector Array (LAMBDA) along with a 24-element multiplicity filter. After pre-equilibrium corrections, the excitation energy E* was averaged over the decay steps of the compound nucleus (CN). The average values of temperature, angular momentum, CN mass etc. have been calculated by the statistical model code CASCADE. Using those average values, results show the systematic increase of GDR width with T which is consistent with Kusnezov parametrization and the Thermal Shape Fluctuation Model. The rise of GDR width with temperature also supports the assumptions of adiabatic coupling in the Thermal Shape Fluctuation Model. But the GDR widths and corresponding reduced plots with J are not consistent with the theoretical model at high spins.

nucl-ex↗

LAMBDA: Large Area Modular BaF2 Detector Array for the measurement of high energy gamma rays

A large BaF2 detector array along with its dedicated CAMAC electronics and VME based data acquisition system has been designed, constructed and installed successfully at VECC, Kolkata for studying high energy gamma rays (E>8 MeV). The array consists of 162 detector elements. The detectors were fabricated from bare barium fluoride crystals (each measuring 35 cm in length and having cross-sectional area of 3.5 cm X 3.5 cm X 35.0 cm). The basic properties of the detectors (energy resolution, time resolution, efficiency, uniformity, fast to slow ratio etc.) were studied exhaustively. Complete GEANT3 monte carlo simulations were performed to optimize the detector design and also to generate the response function. The detector system has been used successfully to measure high energy photons from 113Sb, formed by bombarding 145 and 160 MeV 20Ne beams on a 93Nb target. The measured experimental spectra are in good agreement with those from a modified version of the statistical model code CASCADE. In this paper, we present the complete description of this detector array along with its in-beam performance.

nucl-ex↗