Searcharxiv⌕ Search

arXiv subjects

T. Briant

Publications and source records attributed to T. Briant.

48 records · Page 3Linked to original sources

Characterization of the Virgo Seismic Environment

The Virgo gravitational wave detector is an interferometer (ITF) with 3km arms located in Pisa, Italy. From July to October 2010, Virgo performed its third science run (VSR3) in coincidence with the LIGO detectors. Despite several techniques adopted to isolate the interferometer from the environment, seismic noise remains an important issue for Virgo. Vibrations produced by the detector infrastructure (such as air conditioning units, water chillers/heaters, pumps) are found to affect Virgo's sensitivity, with the main coupling mechanisms being through beam jitter and scattered light processes. The Advanced Virgo (AdV) design seeks to reduce ITF couplings to environmental noise by having most vibration-sensitive components suspended and in-vacuum, as well as muffle and relocate loud machines. During the months of June and July 2010, a Guralp-3TD seismometer was stationed at various locations around the Virgo site hosting major infrastructure machines. Seismic data were examined using spectral and coherence analysis with seismic probes close to the detector. The primary aim of this study was to identify noisy machines which seismically affect the ITF environment and thus require mitigation attention. Analyzed machines are located at various distances from the experimental halls, ranging from 10m to 100m. An attempt is made to measure the attenuation of emitted noise at the ITF and correlate it to the distance from the source and to seismic attenuation models in soil.

gr-qc↗

A micropillar for cavity optomechanics

We present a new micromechanical resonator designed for cavity optomechanics. We have used a micropillar geometry to obtain a high-frequency mechanical resonance with a low effective mass and a very high quality factor. We have coated a 60-$μ$m diameter low-loss dielectric mirror on top of the pillar and are planning to use this micromirror as part of a high-finesse Fabry-Perot cavity, to laser cool the resonator down to its quantum ground state and to monitor its quantum position fluctuations by quantum-limited optical interferometry.

quant-ph↗

Deformable two-dimensional photonic crystal slab for cavity optomechanics

We have designed photonic crystal suspended membranes with optimized optical and mechanical properties for cavity optomechanics. Such resonators sustain vibration modes in the megahertz range with quality factors of a few thousand. Thanks to a two-dimensional square lattice of holes, their reflectivity at normal incidence at 1064 nm reaches values as high as 95%. These two features, combined with the very low mass of the membrane, open the way to the use of such periodic structures as deformable end-mirrors in Fabry-Perot cavities for the investigation of cavity optomechanical effects

physics.optics↗

Back-action amplification and quantum limits in optomechanical measurements

Optical interferometry is by far the most sensitive displacement measurement technique available, with sensitivities at the 10^-20 m/rootHz level in the large-scale gravitational-wave interferometers currently in operation. Second generation interferometers will experience a 10-fold improvement in sensitivity and be mainly limited by quantum noise, close to the Standard Quantum Limit (SQL), once considered as the ultimate displacement sensitivity achievable by interferometry. In this Letter, we experimentally demonstrate one of the techniques envisioned to go beyond the SQL: amplification of a signal by radiation-pressure back-action in a detuned cavity.

quant-ph↗

Probing optomechanical correlations between two optical beams down to the quantum level

Quantum effects of radiation pressure are expected to limit the sensitivity of second-generation gravitational-wave interferometers. Though ubiquitous, such effects are so weak that they haven't been experimentally demonstrated yet. Using a high-finesse optical cavity and a classical intensity noise, we have demonstrated radiation-pressure induced correlations between two optical beams sent into the same moving mirror cavity. Our scheme can be extended down to the quantum level and has applications both in high-sensitivity measurements and in quantum optics.

quant-ph↗

Observation of back-action cancellation in interferometric and weak force measurements

We experimentally demonstrate a cancellation of back-action noise in optical measurements. Back-action cancellation was first proposed within the framework of gravitational-wave detection by dual resonators as a way to drastically improve their sensitivity. We have developed an experiment based on a high-finesse Fabry-Perot cavity to study radiation-pressure effects in ultra-sensitive displacement measurements. Using an intensity-modulated intracavity field to mimic the quantum radiation-pressure noise, we report the first observation of back-action cancellation due to a destructive interference between radiation-pressure effects on both mirrors of the cavity. We have observed a sensitivity improvement by a factor larger than 20 both in displacement and weak force measurements.

quant-ph↗

Radiation-pressure cooling and optomechanical instability of a micro-mirror

Recent experimental progress in table-top experiments or gravitational-wave interferometers has enlightened the unique displacement sensitivity offered by optical interferometry. As the mirrors move in response to radiation pressure, higher power operation, though crucial for further sensitivity enhancement, will however increase quantum effects of radiation pressure, or even jeopardize the stable operation of the detuned cavities proposed for next-generation interferometers. The appearance of such optomechanical instabilities is the result of the nonlinear interplay between the motion of the mirrors and the optical field dynamics. In a detuned cavity indeed, the displacements of the mirror are coupled to intensity fluctuations, which modifies the effective dynamics of the mirror. Such "optical spring" effects have already been demonstrated on the mechanical damping of an electromagnetic waveguide with a moving wall, on the resonance frequency of a specially designed flexure oscillator, and through the optomechanical instability of a silica micro-toroidal resonator. We present here an experiment where a micro-mechanical resonator is used as a mirror in a very high-finesse optical cavity and its displacements monitored with an unprecedented sensitivity. By detuning the cavity, we have observed a drastic cooling of the micro-resonator by intracavity radiation pressure, down to an effective temperature of 10 K. We have also obtained an efficient heating for an opposite detuning, up to the observation of a radiation-pressure induced instability of the resonator. Further experimental progress and cryogenic operation may lead to the experimental observation of the quantum ground state of a mechanical resonator, either by passive or active cooling techniques.

quant-ph↗

High-sensitivity optical monitoring of a micro-mechanical resonator with a quantum-limited optomechanical sensor

We experimentally demonstrate the high-sensitivity optical monitoring of a micro-mechanical resonator and its cooling by active control. Coating a low-loss mirror upon the resonator, we have built an optomechanical sensor based on a very high-finesse cavity (30000). We have measured the thermal noise of the resonator with a quantum-limited sensitivity at the 10^-19 m/rootHz level, and cooled the resonator down to 5K by a cold-damping technique. Applications of our setup range from quantum optics experiments to the experimental demonstration of the quantum ground state of a macroscopic mechanical resonator.

quant-ph↗

Optomechanical characterization of acoustic modes in a mirror

We present an experimental study of the internal mechanical vibration modes of a mirror. We determine the frequency repartition of acoustic resonances via a spectral analysis of the Brownian motion of the mirror, and the spatial profile of the acoustic modes by monitoring their mechanical response to a resonant radiation pressure force swept across the mirror surface. We have applied this technique to mirrors with cylindrical and plano-convex geometries, and compared the experimental results to theoretical predictions. We have in particular observed the gaussian modes predicted for plano-convex mirrors.

quant-ph↗

Thermal and back-action noises in dual-sphere gravitational-waves detectors

We study the sensitivity limits of a broadband gravitational-waves detector based on dual resonators such as nested spheres. We determine both the thermal and back-action noises when the resonators displacements are read-out with an optomechanical sensor. We analyze the contributions of all mechanical modes, using a new method to deal with the force-displacement transfer functions in the intermediate frequency domain between the two gravitational-waves sensitive modes associated with each resonator. This method gives an accurate estimate of the mechanical response, together with an evaluation of the estimate error. We show that very high sensitivities can be reached on a wide frequency band for realistic parameters in the case of a dual-sphere detector.

gr-qc↗

Optical phase-space reconstruction of mirror position at the attometer level

We describe an experiment in which the quadratures of the position of an harmonically-bound mirror are observed at the attometer level. We have studied the Brownian motion of the mirror, both in the free regime and in the cold-damped regime when an external viscous force is applied by radiation pressure. We have also studied the thermal-noise squeezing when the external force is parametrically modulated. We have observed both the 50% theoretical limit of squeezing at low gain and the parametric oscillation of the mirror for a large gain.

quant-ph↗

Full mechanical characterization of a cold damped mirror

We describe an experiment in which we have used a cold damping feedback mechanism to reduce the thermal noise of a mirror around its mechanical resonance frequency. The monitoring of the brownian motion of the mirror allows to apply an additional viscous force without any thermal fluctuations associated. This scheme has been experimentally implemented with the radiation pressure of an intensity-modulated laser beam. Large noise reductions, up to 30 dB, have been obtained. We have also checked the mechanical response of the cold damped mirror, and monitored its transient evolution between the cooled regime and the room temperature equilibrium. A simple theoretical model allows to fully explain the experimental results. A possible application to the active cooling of the violin modes in a gravitational-wave interferometer is discussed.

quant-ph↗