SearcharxivSearch

arXiv subjects

T. E. Gureyev

Publications and source records attributed to T. E. Gureyev.

18 recordsLinked to original sources

On imaging capabilities of the Imaging and Medical beamline at the Australian Synchrotron

Several propagation-based and analyser-based X-ray phase-contrast imaging experiments with over 100 m between the imaged objects and the detector were carried out at the Imaging and Medical beamline (IMBL) of the Australian Synchrotron. These experiments were aimed at characterization of possible phase-contrast imaging setups at IMBL. Effects of the beam divergence, polychromaticity and X-ray source size on the contrast and spatial resolution of images were evaluated quantitatively in different imaging scenarios. The results of this work will be used for improving the existing and developing new imaging capabilities at the beamline. Applications to X-ray phase-contrast tomography of biomedical samples, particularly for medical breast cancer imaging, are briefly discussed.

physics.optics

Signal-to-noise and spatial resolution in in-line imaging. 3. Optimization using a simple model

The problem of optimization of propagation-based phase-contrast imaging setups is considered in the case of projection X-ray imaging and three-dimensional tomography with phase retrieval. For two-dimensional imaging, a simple model for a homogeneous edge feature embedded in a bulk sample is used to obtain analytical expressions for the image intensity. This model allows for explicit optimization of the geometrical parameters of the imaging setup and the choice of X-ray energy that maximizes the image contrast or the contrast-to-noise ratio. We also consider the question of optimization of the biomedical X-ray imaging quality characteristic which balances the contrast-to-noise against the spatial resolution and the radiation dose. In the three-dimensional case corresponding to propagation-based phase-contrast tomography with phase retrieval according to Paganin's method, the optimization of the imaging setup is studied with respect to the source size, the detector resolution, the geometrical magnification and the X-ray energy.

physics.med-ph

Signal-to-noise and spatial resolution in in-line imaging. 2. Phase-contrast tomography

In the first part of this paper, quantitative aspects of propagation-based phase-contrast imaging (PBI) were investigated using theoretical and numerical approaches, as well as experimental two-dimensional PBI images collected with plane monochromatic X-rays at a synchrotron beamline. In this second part, signal-to-noise ratio, spatial resolution and contrast are studied in connection with the radiation dose in three-dimensional PBI images of breast tissue samples obtained using propagation-based phase-contrast computed tomography (PB-CT) with energy-integrating and photon-counting detectors. The analysis is based on the theory of PBI and PB-CT using the homogeneous Transport of Intensity equation (Paganin's method). A biomedical image quality characteristic, suitable for quantitative assessment of X-ray images of biological samples, is introduced and applied. The key factors leading to high values of the biomedical imaging quality in PBI and to relatively low values of the same quality metric in CT imaging are identified and discussed in detail. This study is aimed primarily at developing tools for quantitative assessment and optimization of medical PB-CT imaging, initially at synchrotron facilities, with the prospect of subsequent transfer of the technology to medical clinics.

physics.med-ph

Young double-slit interference with single hard x-ray photons

Young double-slit experiments using monochromatic hard X-rays with the energy of 25 keV are presented. The experiments were performed at a synchrotron source with a distance of 110 m between the interferometer and the detector to produce an interference pattern with a sufficiently broad period that could be adequately sampled by a photon-counting detector with 75 micrometre pixels. In the single-particle version of the experiment, over one million image frames with a single registered photon in each one were collected. The sum of these frames showed a clear presence of the interference pattern with the expected period. Subsequent analysis provided an objective estimation of the minimal number of detected photons required to determine, in accordance with the Rose criterion, the presence of the photon interference. Apart from a general theoretical interest, these investigations were aimed at exploring the possibility of medical X-ray phase-contrast imaging in photon-counting mode at minimal radiation doses.

physics.optics

Signal-to-noise and spatial resolution in in-line imaging. 1. Basic theory, numerical simulations and planar experimental images

Signal-to-noise ratio and spatial resolution are quantitatively analysed in the context of in-line (propagation based) X-ray phase-contrast imaging. It is known that free-space propagation of a coherent X-ray beam from the imaged object to the detector plane, followed by phase retrieval in accordance with Paganin's method, can increase the signal-to-noise in the resultant images without deteriorating the spatial resolution. This results in violation of the noise-resolution uncertainty principle and demonstrates "unreasonable" effectiveness of the method. On the other hand, when the process of free-space propagation is performed in software, using the detected intensity distribution in the object plane, it cannot reproduce the same effectiveness, due to the amplification, during free-space propagation, of photon shot noise in the object-plane intensity. We show that the performance of Paganin's method is determined by just two dimensionless parameters: the Fresnel number and the ratio of the phase shift to the logarithm of intensity in the object plane. The relevant theoretical analysis is performed first, followed by computer simulations and then by a brief test using experimental images collected at a synchrotron beamline. More extensive experimental tests will be presented in the second part of this paper.

physics.med-ph

A method for virtual optical sectioning and tomography utilizing shallow depth of field

A method is proposed for high-resolution, three-dimensional reconstruction of internal structure of objects from planar transmission images. The described approach can be used with any form of radiation or matter waves, in principle, provided that the depth of field is smaller than the thickness of the sample. The physical optics basis for the method is elucidated and the reconstruction algorithm is presented in detail. A simulated example demonstrates an application of the method to three-dimensional electron transmission imaging of a nanoparticle under realistic radiation dose and spatial resolution constraints. It is envisaged that the method can be applicable in high-resolution transmission electron microscopy, soft X-ray microscopy, ultrasound imaging and other areas.

physics.optics

Relative roles of multiple scattering and Fresnel diffraction in the imaging of small molecules using electrons, Part II: Differential Holographic Tomography

It has been argued that in atomic-resolution transmission electron microscopy (TEM) of sparse weakly scattering structures, such as small biological molecules, multiple electron scattering usually has only a small effect, while the in-molecule Fresnel diffraction can be significant due to the intrinsically shallow depth of focus. These facts suggest that the three-dimensional reconstruction of such structures from defocus image series collected at multiple rotational orientations of a molecule can be effectively performed for each atom separately, using the incoherent first Born approximation. The corresponding reconstruction method, termed here Differential Holographic Tomography, is developed theoretically and demonstrated computationally on several numerical models of biological molecules. It is shown that the method is capable of accurate reconstruction of the locations of atoms in a molecule from TEM data collected at a small number of random orientations of the molecule, with one or more defocus images per orientation. Possible applications to cryogenic electron microscopy and other areas are briefly discussed.

physics.optics

Dark-field signal extraction in propagation-based phase-contrast imaging

A method for extracting the dark-field signal in propagation-based phase-contrast imaging is proposed. In the case of objects consisting predominantly of a single material, or several different materials with similar ratios of the real decrement to the imaginary part of the complex refractive index, the proposed method requires a single image for extraction of the dark-field signal in two-dimensional projection imaging. In the case of three-dimensional tomographic imaging, the method needs only one image to be collected at each projection angle. A preliminary example demonstrates that this method can improve the visualization of microcalcifications in propagation-based X-ray breast cancer imaging. It is suggested that the proposed approach may be useful in other forms of biomedical imaging, where it can help one to obtain additional small-angle scattering information without increasing the radiation dose to the sample.

physics.med-ph

On electron imaging of small molecules, Part II: tomographic reconstruction from defocus series

A practical method utilising three-dimensional image pattern matching is proposed which, in principle, is capable of unambiguous determination of the types and positions of atoms in small molecules from defocus series collected at only a few different angular orientations of the molecule. Numerical tests of the method are presented using multislice calculations of defocus series of small biological molecules. The proposed technique can in future gain from Bayesian or machine-learning approaches and is likely to be useful in cryogenic electron microscopy.

eess.IV

On electron imaging of small molecules, Part I: relative roles of multiple scattering and Fresnel diffraction

The relative roles of multiple electron scattering and in-molecule free-space propagation in transmission electron microscopy of small molecules are discussed. It is argued that while multiple scattering tends to have only a moderate effect in this case, the in-molecule Fresnel diffraction is likely to be significant due to the shallow depth of focus under the relevant experimental conditions. As a consequence, diffraction tomography based on the first Born or first Rytov approximation represents a more suitable method for the reconstruction of three-dimensional distribution of the electrostatic potential in this context, compared to conventional computed tomography which is intrinsically based on the projection approximation. A simplified method for diffraction tomography is proposed and tested on numerically simulated examples.

eess.IV

On the efficiency of computational imaging with structured illumination

A generic computational imaging setup is considered which assumes sequential illumination of a semi-transparent object by an arbitrary set of structured illumination patterns. For each incident illumination pattern, all transmitted light is collected by a photon-counting bucket (single-pixel) detector. The transmission coefficients measured in this way are then used to reconstruct the spatial distribution of the object's projected transmission. It is demonstrated that the squared spatial resolution of such a setup is usually equal to the ratio of the image area to the number of linearly independent illumination patterns. If the noise in the measured transmission coefficients is dominated by photon shot noise, then the ratio of the spatially-averaged squared mean signal to the spatially-averaged noise variance in the "flat" distribution reconstructed in the absence of the object, is equal to the average number of registered photons when the illumination patterns are orthogonal. The signal-to-noise ratio in a reconstructed transmission distribution is always lower in the case of non-orthogonal illumination patterns due to spatial correlations in the measured data. Examples of imaging methods relevant to the presented analysis include conventional imaging with a pixelated detector, computational ghost imaging, compressive sensing, super-resolution imaging and computed tomography.

eess.IV

On the "unreasonable" effectiveness of Transport of Intensity imaging and optical deconvolution

The effectiveness of reconstructive imaging using the Homogeneous Transport of Intensity equation may be regarded as "unreasonable", because it has been shown to significantly increase signal-to-noise ratio while preserving spatial resolution, compared to equivalent conventional absorption-based imaging techniques at the same photon fluence. We reconcile this surprising behaviour by analysing the propagation of noise in typical in-line holography experiments. This analysis indicates that novel imaging techniques may be designed which produce high signal-to-noise images at low radiation doses without sacrificing spatial resolution.

physics.optics

Monomorphous decomposition method for phase retrieval and phase-contrast tomography

We show that an arbitrary spatial distribution of complex refractive index inside an object can be exactly represented as a sum of two "monomorphous" complex distributions, i.e. the distributions with the ratios of the real part to the imaginary part being constant throughout the object. A priori knowledge of constituent materials can be used to estimate the global lower and upper boundaries for this ratio. This approach can be viewed as an extension of the successful phase-retrieval method, based on the Transport of Intensity equation, that was previously developed for monomorphous (homogeneous) objects, such as e.g. objects consisting of a single material. We demonstrate that the monomorphous decomposition can lead to more stable methods for phase retrieval using the Transport of Intensity Equation. Such methods may find application in quantitative in-line phase-contrast imaging and phase-contrast tomography.

physics.med-ph

Evaluating the Performance of BSBL Methodology for EEG Source Localization On a Realistic Head Model

Source localization in EEG represents a high dimensional inverse problem, which is severely ill-posed by nature. Fortunately, sparsity constraints have come into rescue as it helps solving the ill-posed problems when the signal is sparse. When the signal has a structure such as block structure, consideration of block sparsity produces better results. Knowing sparse Bayesian learning is an important member in the family of sparse recovery, and a superior choice when the projection matrix is highly coherent (which is typical the case for EEG), in this work we evaluate the performance of block sparse Bayesian learning (BSBL) method for EEG source localization. It is already accepted by the EEG community that a group of dipoles rather than a single dipole are activated during brain activities; thus, block structure is a reasonable choice for EEG. In this work we use two definitions of blocks: Brodmann areas and automated anatomical labelling (AAL), and analyze the reconstruction performance of BSBL methodology for them. A realistic head model is used for the experiment, which was obtained from segmentation of MRI images. When the number of simultaneously active blocks is 2, the BSBL produces overall localization accuracy of less than 5 mm without the presence of noise. The presence of more than 3 simultaneously active blocks and noise significantly affect the localization performance. Consideration of AAL based blocks results more accurate source localization in comparison to Brodmann area based blocks.

physics.med-ph

Linear algorithms for phase retrieval in the Fresnel region: validity conditions

We describe the relationship between different forms of linearized expressions for the spatial distribution of intensity of X-ray projection images obtained in the Fresnel region. We prove that under the natural validity conditions some of the previously published expressions can be simplified without a loss of accuracy. We also introduce modified validity conditions which are likely to be fulfilled in many relevant practical cases, and which lead to a further significant simplification of the expression for the image-plane intensity, permitting simple non-iterative linear algorithms for the phase retrieval.

physics.med-ph

On the noise-resolution duality, Heisenberg uncertainty and Shannon's information

Several variations of the Heisenberg uncertainty inequality are derived on the basis of "noise-resolution duality" recently proposed by the authors. The same approach leads to a related inequality that provides an upper limit for the information capacity of imaging systems in terms of the number of imaging quanta (particles) used in the experiment. These results can be useful in the context of biomedical imaging constrained by the radiation dose delivered to the sample, or in imaging (e.g. astronomical) problems under "low light" conditions.

physics.med-ph

Sparse Bayesian Learning for EEG Source Localization

Purpose: Localizing the sources of electrical activity from electroencephalographic (EEG) data has gained considerable attention over the last few years. In this paper, we propose an innovative source localization method for EEG, based on Sparse Bayesian Learning (SBL). Methods: To better specify the sparsity profile and to ensure efficient source localization, the proposed approach considers grouping of the electrical current dipoles inside human brain. SBL is used to solve the localization problem in addition with imposed constraint that the electric current dipoles associated with the brain activity are isotropic. Results: Numerical experiments are conducted on a realistic head model that is obtained by segmentation of MRI images of the head and includes four major components, namely the scalp, the skull, the cerebrospinal fluid (CSF) and the brain, with appropriate relative conductivity values. The results demonstrate that the isotropy constraint significantly improves the performance of SBL. In a noiseless environment, the proposed method was 1 found to accurately (with accuracy of >75%) locate up to 6 simultaneously active sources, whereas for SBL without the isotropy constraint, the accuracy of finding just 3 simultaneously active sources was <75%. Conclusions: Compared to the state-of-the-art algorithms, the proposed method is potentially more consistent in specifying the sparsity profile of human brain activity and is able to produce better source localization for EEG.

q-bio.QM

EEG source localization using a sparsity prior based on Brodmann areas

Localizing the sources of electrical activity in the brain from Electroencephalographic (EEG) data is an important tool for non-invasive study of brain dynamics. Generally, the source localization process involves a high-dimensional inverse problem that has an infinite number of solutions and thus requires additional constraints to be considered to have a unique solution. In the context of EEG source localization, we propose a novel approach that is based on dividing the cerebral cortex of the brain into a finite number of Functional Zones which correspond to unitary functional areas in the brain. In this paper we investigate the use of Brodmanns areas as the Functional Zones. This approach allows us to apply a sparsity constraint to find a unique solution for the inverse EEG problem. Compared to previously published algorithms which use different sparsity constraints to solve this problem, the proposed method is potentially more consistent with the known sparsity profile of the human brain activity and thus may be able to ensure better localization. Numerical experiments are conducted on a realistic head model obtained from segmentation of MRI images of the head and includes four major compartments namely scalp, skull, cerebrospinal fluid (CSF) and brain with relative conductivity values. Three different electrode setups are tested in the numerical experiments.

q-bio.QM