Searcharxiv⌕ Search

arXiv subjects

T. E. Parker

Publications and source records attributed to T. E. Parker.

4 recordsLinked to original sources

Towards Adoption of an Optical Second: Verifying Optical Clocks at the SI Limit

The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave transition between hyperfine levels in ground-state $^{133}$Cs, it is necessary to measure the absolute frequency of candidate standards, which is done by comparing against a primary cesium reference. A key verification of this process can be achieved by performing a loop closure$-$comparing frequency ratios derived from absolute frequency measurements against ratios determined from direct optical comparisons. We measure the $^1$S$_0\!\rightarrow^3$P$_0$ transition of $^{171}$Yb by comparing the clock frequency to an international frequency standard with the aid of a maser ensemble serving as a flywheel oscillator. Our measurements consist of 79 separate runs spanning eight months, and we determine the absolute frequency to be 518 295 836 590 863.71(11) Hz, the uncertainty of which is equivalent to a fractional frequency of $2.1\times10^{-16}$. This absolute frequency measurement, the most accurate reported for any transition, allows us to close the Cs-Yb-Sr-Cs frequency measurement loop at an uncertainty of $<$3$\times10^{-16}$, limited by the current realization of the SI second. We use these measurements to tighten the constraints on variation of the electron-to-proton mass ratio, $μ=m_e/m_p$. Incorporating our measurements with the entire record of Yb and Sr absolute frequency measurements, we infer a coupling coefficient to gravitational potential of $k_\mathrmμ=(-1.9\pm 9.4)\times10^{-7}$ and a drift with respect to time of $\frac{\dotμ}μ=(5.3 \pm 6.5)\times10^{-17}/$yr.

physics.atom-ph↗

Precision measurement of the speed of propagation of neutrinos using the MINOS detectors

We report a two-detector measurement of the propagation speed of neutrinos over a baseline of 734 km. The measurement was made with the NuMI beam at Fermilab between the near and far MINOS detectors. The fractional difference between the neutrino speed and the speed of light is determined to be $(v/c-1) = (1.0 \pm 1.1) \times 10^{-6}$, consistent with relativistic neutrinos.

hep-ex↗

Spin-1/2 Optical Lattice Clock

We experimentally investigate an optical clock based on $^{171}$Yb ($I=1/2$) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of $3.4 \times 10^{-16}$, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.

physics.atom-ph↗

Testing the stability of fundamental constants with the 199Hg+ single-ion optical clock

Over a two-year duration, we have compared the frequency of the 199Hg+ 5d106s 2S 1/2 (F=0)<-> 5d9 6s2 2D 5/2 (F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/- 7 10^-15 / yr (1 sigma uncertainty). According to recent atomic structure calculations, this sets an upper limit to a possible fractional time variation of g(Cs) m_e / m_p alpha^6.0 at the same level.

physics.atom-ph↗