SearcharxivSearch

arXiv subjects

T. Grimm

Publications and source records attributed to T. Grimm.

4 recordsLinked to original sources

High brightness CW electron beams from Superconducting RF photoemission gun

CW photoinjectors operating at high accelerating gradients promise to revolutionize many areas of science and applications. They can establish the basis for a new generation of monochromatic X-ray free electron lasers, high brightness hadron beams, or a new generation of microchip production. In this letter we report on the record-performing superconducting RF electron gun with $\textrm{CsK}_{2}\textrm{Sb}$ photocathode. The gun is generating high charge electron bunches (up to 10 nC/bunch) and low transverse emittances, while operating for months with a single photocathode. This achievement opens a new era in generating high-power beams with a very high average brightness.

physics.acc-ph

Design and Vertical Tests of SPS-series Double-Quarter Wave (DQW) Cavity Prototypes for the HL-LHC Crab Cavity System

Crab crossing is essential for high-luminosity colliders. The High Luminosity Large Hadron Collider (HL-LHC) will equip one of its Interaction Points (IP1) with Double-Quarter Wave (DQW) crab cavities. A DQW cavity is a new generation of deflecting RF cavities that stands out for its compactness and broad frequency separation between fundamental and first high-order modes. The deflecting kick is provided by its fundamental mode. Each HL-LHC DQW cavity shall provide a nominal deflecting voltage of 3.4 MV, although up to 5.0 MV may be required. A Proof-of-Principle (PoP) DQW cavity was limited by quench at 4.6 MV. This paper describes a new, highly optimized cavity, designated DQW SPS-series, which satisfies dimensional, cryogenic, manufacturing and impedance requirements for beam tests at SPS and operation in LHC. Two prototypes of this DQW SPS-series were fabricated by US industry and cold tested after following conventional SRF surface treatment. Both units outperformed the PoP cavity, reaching a deflecting voltage of 5.3-5.9 MV. This voltage - the highest reached by a DQW cavity - is well beyond the nominal voltage of 3.4 MV and may even operate at the ultimate voltage of 5.0MVwith sufficient margin. This paper covers fabrication, surface preparation and cryogenic RF test results and implications.

physics.acc-ph

Niobium Quarter-Wave Resonator Development for The Rare Isotope Accelerator

Two superconducting quarter-wave resonator (QWR) prototypes have been fabricated and tested. They operate at 80.5 MHz and 161 MHz and are optimised for beta = 0.085 and beta = 0.16, respectively. The prototypes are simplified versions without integrated helium vessels. In the first RF tests, the beta = 0.085 QWR reached a peak surface electric field (Ep) in excess of 30 MV/m, with an intrinsic quality factor (Q0) in excess of 1E9 at the design field of Ep = 20 MV/m. The beta = 0.16 QWR reached Ep = 20 MV/m with Q0 = 2.5E9. It is suspected that the performance of the latter cavity can be improved via better cooling of the Nb tuning plate and a better RF contact between the plate and the outer conductor.

physics.acc-ph

Analysis of a Cyclotron Based 400 MeV/u Driver System for a Radioactive Beam Facility

The creation of intense radioactive beams requires intense and energetic primary beams. A task force analysis of this subject recommended an acceleration system capable of 400 MeV/u uranium at 1 particle uA as an appropriate driver for such a facility. The driver system should be capable of accelerating lighter ions at higher intensity such that a constant final beam power (~100kW) is maintained. This document is a more detailed follow on to the previous analysis of such a system incorporating a cyclotron. The proposed driver pre-acceleration system consists of an ion source, radio frequency quadrupole, and linac chain capable of producing a final energy of 30 MeV/u and a charge (Q) to mass (A) of Q/A ~1/3. This acceleration system would be followed by a Separated Sector Cyclotron with a final output energy of 400 MeV/u. This system provides a more cost-effective solution in terms of initial capital investment as well as of operation compared to a fully linac system with the same primary beam output parameters.

nucl-ex