SearcharxivSearch

arXiv subjects

T. Guallart-Naval

Publications and source records attributed to T. Guallart-Naval.

5 recordsLinked to original sources

A fully open-source framework for streaming and cloud-processing of low-field MRI data

Purpose: To present a fully open-source framework for quasi-real-time streaming and cloud-based processing of low-field (LF) MRI data, addressing the growing computational demands of advanced reconstruction and post-processing pipelines in portable and affordable MRI systems. Methods: The proposed framework integrates open-source scanner control software with a network-enabled streaming architecture, allowing for raw data to be transmitted directly from the MRI console to remote compute resources. Cloud-based processing modules support image reconstruction and advanced post-processing, including computationally intensive physics- and learning-based methods, while maintaining compatibility with low-cost on-device control hardware. Results: The system enables continuous acquisition-to-reconstruction workflows in LF-MRI without requiring specialized high-performance console architectures. Selected example applications include deep-learning-based denoising, field-induced distortion correction, and non-Cartesian image reconstruction. Experimental demonstrations show reliable streaming performance. Conclusions: Open-source streaming and cloud-processing provide an effective pathway to overcome the computational limitations of embedded LF-MRI consoles. By decoupling acquisition hardware from intensive reconstruction workloads, the proposed framework supports scalable deployment of advanced algorithms while preserving the affordability and portability that motivate LF-MRI.

physics.comp-ph

MaRGA: a Graphical and Application Interface for MaRCoS

The open-source console MaRCoS, which stands for "Magnetic Resonance Control System", combines hardware, firmware and software elements for integral control of Magnetic Resonance Imaging (MRI) scanners. Previous developments have focused on making the system robust and reliable, rather than on users, who have been somewhat overlooked. This work describes a Graphical User Interface (GUI) designed for intuitive control of MaRCoS, as well as compatibility with clinical environments. The GUI is based on an uncomplicated set of panels and a renewed Application Program Interface (API). Compared to the previous versions, the MaRGA package ("MaRCoS Graphical Application") includes new functionalities such as the possibility to export images to standard DICOM formats, create and manage clinical protocols, or display and process image reconstructions, among other features conceived to simplify the operation of MRI scanners. All prototypes in our facilities are commanded by MaRCoS and operated with the new GUI. Here we report on its performance on an experimental 0.2 T scanner designed for hard-tissue imaging, as well as a 72~mT portable scanner presently installed in the radiology department of a large hospital. The possibility to customize, adapt and streamline processes has substantially improved our workflows and overall experience.

physics.med-ph

Portable MRI for major sporting events -- a case study on the MotoGP World Championship

The goal of this work is to showcase the clinical value that portable MRI can provide in crowded events and major sports competitions. We temporarily installed a low-field and low-cost portable MRI system for extremity imaging in the medical facilities of the Ricardo Tormo Motor Racing Circuit during the four days of the Motorcycle Grand Prix held in Valencia (Spain), which closed the 2022 season of the MotoGP. During this time, we scanned 14 subjects, running a total of 21 protocols for wrist, knee and ankle imaging. Each protocol included a minimum of one T1-weighted 3D-RARE sequence for general anatomical information, and one 3D-STIR sequence to highlight fluid accumulation and inflammation. The circuit medical staff were able to visualize a number of lesions and conditions in the low-field reconstructions, including gonarthrosis, effusion, or Haglund's syndrome, as well as metallic implants and tissue changes due to surgical interventions. Out of eight low-field acquisitions on previously diagnosed lesions, only two (a meniscus tear and a Baker cyst) were not detected by the experts that evaluated our images. The main highlight was that a low-field MRI scan on a subject reporting pain in a wrist revealed a traumatic arthritis which an X-ray radiograph and visual inspection had missed. We have operated in a scenario where high-field MRI is unlikely to play a role but where a low-field system can lead to improved medical attention. In the case reported here, system transport, installation in the circuit facilities and calibration were all uncomplicated. The images presented to the medical staff were mostly unprocessed and there is thus room for improvement. In conclusion, this work supports the claim that low-field MRI can likely provide added value whenever concepts such as accessibility, portability and low-cost outweigh exquisite detail in images.

physics.med-ph

Benchmarking the performance of a low-cost Magnetic Resonance Control System at multiple sites in the open MaRCoS community

Purpose: To describe the current properties and capabilities of an open-source hardware and software package that is being developed by many sites internationally with the aim of providing an inexpensive yet flexible platform for low-cost MRI. Methods: This paper describes three different setups from 50 to 360 mT in different settings, all of which used the MaRCoS console for acquiring data, and different types of software interfaces (custom-built GUI or PulSeq overlay) to acquire the data. Results: Images are presented from both phantoms and in vivo from healthy volunteers to demonstrate the image quality that can be obtained from the MaRCoS hardware/software interfaced to different low-field magnets. Conclusions: The results presented here show that a number of different sequences commonly used in the clinic can be programmed into an open-source system relatively quickly and easily, and can produce good quality images even at this early stage of development. Both the hardware and software will continue to develop, and it is an aim of this paper to encourage other groups to join this international consortium.

physics.med-ph

Portable magnetic resonance imaging of patients indoors, outdoors and at home

Mobile medical imaging devices are invaluable for clinical diagnostic purposes both in and outside healthcare institutions. Among the various imaging modalities, only a few are readily portable. Magnetic resonance imaging (MRI), the gold standard for numerous healthcare conditions, does not traditionally belong to this group. Recently, low-field MRI start-up companies have demonstrated the first decisive steps towards portability within medical facilities, but these are so far incompatible with more demanding use cases such as in remote and developing regions, sports facilities and events, medical and military camps, or home healthcare. Here we present in vivo images taken with a light, home-made, low-field extremity MRI scanner outside the controlled environment provided by medical facilities. To demonstrate the true portability of the system and benchmark its performance in various relevant scenarios, we have acquired images of a volunteer's knee in: i) an MRI physics laboratory; ii) an office room; iii) outside a campus building, connected to a nearby power outlet; iv) in open air, powered from a small fuel-based generator; and v) at the volunteer's home. All images have been acquired within clinically viable times, and signal-to-noise ratios (SNR) and tissue contrast suffice for 2D and 3D reconstructions with diagnostic value, with comparable overall image quality across all five situations. Furthermore, the volunteer carries a fixation metallic implant screwed to the femur, which leads to strong artifacts in standard clinical systems but appears sharp in our low-field acquisitions. Altogether, this work opens a path towards highly accessible MRI under circumstances previously unrealistic.

physics.med-ph