SearcharxivSearch

arXiv subjects

T. Hebbeker

Publications and source records attributed to T. Hebbeker.

8 recordsLinked to original sources

Efficiency measurements of GEM GE1/1 chambers in the upgraded CMS Endcap Muon System using 2023 collision data at $\sqrt{s}=13.6$ TeV

The CMS experiment at the Large Hadron Collider employs Gas Electron Multiplier (GEM) detectors, a technology based on gaseous ionization, as one of the muon detectors. The muon spectrometer is being upgraded to handle the increased muon flux in the forward region. This study analyzes muon detection efficiency in the GE1/1 triple-GEM detector, using 2023 proton-proton collision data at $\sqrt{s}=13.6$ TeV. A dataset enriched with muons from Z boson decay, with a total recorded luminosity of 17.8 fb$^{-1}$ has been used for this study. The detection efficiency of 137 GEM detectors are measured using muon trajectories established using other detectors in the tracking and muon systems, without use of the GEM detectors. The average efficiency of 137 GEM detectors is $\sim$93.3$\%$. A subset of 108 detectors that had no shorts were operated at the nominal HV working point with average efficiency of $\sim$96$\%$. Efficiency is found to be unaffected by the number of p-p interactions per bunch crossing (pile-up).

hep-ex

The Analytical Method algorithm for trigger primitives generation at the LHC Drift Tubes detector

The Compact Muon Solenoid (CMS) experiment prepares its Phase-2 upgrade for the high-luminosity era of the LHC operation (HL-LHC). Due to the increase of occupancy, trigger latency and rates, the full electronics of the CMS Drift Tube (DT) chambers will need to be replaced. In the new design, the time bin for the digitisation of the chamber signals will be of around 1~ns, and the totality of the signals will be forwarded asynchronously to the service cavern at full resolution. The new backend system will be in charge of building the trigger primitives of each chamber. These trigger primitives contain the information at chamber level about the muon candidates position, direction, and collision time, and are used as input in the L1 CMS trigger. The added functionalities will improve the robustness of the system against ageing. An algorithm based on analytical solutions for reconstructing the DT trigger primitives, called Analytical Method, has been implemented both as a software C++ emulator and in firmware. Its performance has been estimated using the software emulator with simulated and real data samples, and through hardware implementation tests. Measured efficiencies are 96 to 98\% for all qualities and time and spatial resolutions are close to the ultimate performance of the DT chambers. A prototype chain of the HL-LHC electronics using the Analytical Method for trigger primitive generation has been installed during Long Shutdown 2 of the LHC and operated in CMS cosmic data taking campaigns in 2020 and 2021. Results from this validation step, the so-called Slice Test, are presented.

hep-ex

E-TEST prototype design report

E-TEST (Einstein Telescope Euregio-Meuse-Rhin Site and Technology) is a project recently funded by the European program Ineterreg Euregio Meuse-Rhine. This program is dedicated to innovative cross boarder activities between Belgium, The Netherlands and Germany. With a total budget of15MC and a consortium of 11 partners from the three countries, the objective of the project is twofold. Firstly, to develop an eco-friendly and non-invasive imaging of the geological conditions as well as the development of an observatory of the underground in the EMR region. Secondly, to develop technologies necessary for 3rd generation gravitational wave detectors. In particular, it is proposed to develop a prototype of large suspended cryogenic silicon mirror, isolated from seismic vibrations at low frequency. The total budget of the project is equally spread over the two activities. The first activity is not discussed at all in this report. The E-TEST prototype will have some key unique features: a silicon mirror of 100 kg, a radiative cooling strategy (non contact), a low-frequency hybrid isolation stage, cryogenic sensors and electronics, a laser and optics at 2 microns, a low thermal noise coating.

astro-ph.IM

Extending the dynamic range of SiPMs by understanding their non-linear behavior

This publication focuses on the study of silicon photomultipliers (SiPMs) in view of a reconstruction of the incident photon flux in the regime of highly non-linear response. SiPMs are semiconductor based light detectors compiled of avalanche photodiodes operated in Geiger mode. They are both mechanically and optically very robust and have a high gain and photon detection efficiency. These features make them ideal photonsensors in a wide range of applications and they are nowadays replacing conventional photomultiplier tubes in many experiments. The cellular structure of SiPMs where each cell can only detect one photon at a time results in a non-linear dynamic range limiting the possible applications. We studied a commonly used SiPM model based on an equivalent electronic circuit that allows the simulation of the SiPM response in many situations. Dedicated measurements with two consecutive light pulses prove its applicability. By adapting the model to the measurements, intrinsic parameters of the SiPM such as quenching resistance or diode capacitance can be determined. With the obtained intrinsic parameters, the model correctly describes the recharge behavior of the SiPM cells. Based on the model, an algorithm was developed to correct the non-linearity of the dynamic range of SiPMs. As the model contains full information on the recharge of the SiPM cells, the effects leading to the non-linearity can be corrected for. The algorithm exploits the time information in the measured voltage signal and reconstructs the number of incident photons. It has shown an excellent performance and allows to increase the dynamic range with only 10% deviation from linearity by at least two orders of magnitude.

physics.ins-det

Study of the effects of radiation on the CMS Drift Tubes Muon Detector for the HL-LHC

The CMS drift tubes (DT) muon detector, built for withstanding the LHC expected integrated and instantaneous luminosities, will be used also in the High Luminosity LHC (HL-LHC) at a 5 times larger instantaneous luminosity and, consequently, much higher levels of radiation, reaching about 10 times the LHC integrated luminosity. Initial irradiation tests of a spare DT chamber at the CERN gamma irradiation facility (GIF++), at large ($\sim$O(100)) acceleration factor, showed ageing effects resulting in a degradation of the DT cell performance. However, full CMS simulations have shown almost no impact in the muon reconstruction efficiency over the full barrel acceptance and for the full integrated luminosity. A second spare DT chamber was moved inside the GIF++ bunker in October 2017. The chamber was being irradiated at lower acceleration factors, and only 2 out of the 12 layers of the chamber were switched at working voltage when the radioactive source was active, being the other layers in standby. In this way the other non-aged layers are used as reference and as a precise and unbiased telescope of muon tracks for the efficiency computation of the aged layers of the chamber, when set at working voltage for measurements. An integrated dose equivalent to two times the expected integrated luminosity of the HL-LHC run has been absorbed by this second spare DT chamber and the final impact on the muon reconstruction efficiency is under study. Direct inspection of some extracted aged anode wires presented a melted resistive deposition of materials. Investigation on the outgassing of cell materials and of the gas components used at the GIF++ are underway. Strategies to mitigate the ageing effects are also being developed. From the long irradiation measurements of the second spare DT chamber, the effects of radiation in the performance of the DTs expected during the HL-LHC run will be presented.

physics.ins-det

A compact and light-weight refractive telescope for the observation of extensive air showers

A general purpose instrument for imaging of Cherenkov light or fluorescence light emitted by extensive air showers is presented. Its refractive optics allows for a compact and light-weight design with a wide field-of-view of 12°. The optical system features a 0.5 m diameter Fresnel lens and a camera with 61 pixels composed of Winston cones and large-sized 6x6 mm photo sensors. As photo sensors, semi conductor light sensors (SiPMs) are utilized. The camera provides a high photon detection efficiency together with robust operation. The enclosed optics permit operation in regions of harsh environmental conditions. The low price of the telescope allows the production of a large number of telescopes and the application of the instrument in various projects, such as FAMOUS for the Pierre Auger Observatory, HAWC's Eye for HAWC or IceAct for IceCube. In this paper the novel design of this telescope and first measurements are presented.

astro-ph.IM

An integrated general purpose SiPM based optical module with a high dynamic range

Silicon photomultipliers (SiPMs) are semiconductor-based light-sensors offering a high gain, a mechanically and optically robust design and high photon detection efficiency. Due to these characteristics, they started to replace conventional photomultiplier tubes in many applications in recent years. This paper presents an optical module based on SiPMs designed for the application in scintillators as well as lab measurements. The module hosts the SiPM bias voltage supply and three pre-amplifiers with different gain levels to exploit the full dynamic range of the SiPMs. Two SiPMs, read-out in parallel, are equipped with light guides to increase the sensitive area. The light guides are optimized for the read-out of wavelength shifting fibers as used in many plastic scintillator detectors. The optical and electrical performance of the module is characterized in detail in laboratory measurements. Prototypes have been installed and tested in a modified version of the Scintillator Surface Detector developed for AugerPrime, the upgrade of the Pierre Auger Observatory. The SiPM module is operated in the Argentinian Pampas and first data proves its usability in such harsh environments.

physics.ins-det

Hadron-Hadron and Cosmic-Ray Interactions at multi-TeV Energies

The workshop on "Hadron-Hadron and Cosmic-Ray Interactions at multi-TeV Energies" held at the ECT* centre (Trento) in Nov.-Dec. 2010 gathered together both theorists and experimentalists to discuss issues of the physics of high-energy hadronic interactions of common interest for the particle, nuclear and cosmic-ray communities. QCD results from collider experiments -- mostly from the LHC but also from the Tevatron, RHIC and HERA -- were discussed and compared to various hadronic Monte Carlo generators, aiming at an improvement of our theoretical understanding of soft, semi-hard and hard parton dynamics. The latest cosmic-ray results from various ground-based observatories were also presented with an emphasis on the phenomenological modeling of the first hadronic interactions of the extended air-showers generated in the Earth atmosphere. These mini-proceedings consist of an introduction and short summaries of the talks presented at the meeting.

hep-ex