SearcharxivSearch

arXiv subjects

T. Idehara

Publications and source records attributed to T. Idehara.

7 recordsLinked to original sources

First Millimeter-wave Spectroscopy of the Ground-state Positronium

We report on the first measurement of the Breit-Wigner resonance of the transition from {\it ortho-}positronium to {\it para-}positronium. We have developed an optical system to accumulate a power of over 20 kW using a frequency-tunable gyrotron and a Fabry-Pérot cavity. This system opens a new era of millimeter-wave spectroscopy, and enables us to directly determine both the hyperfine interval and the decay width of {\it p-}Ps.

hep-ex

Direct Observation of the Hyperfine Transition of the Ground State Positronium

We report the first direct measurement of the hyperfine transition of the ground state positronium. The hyperfine structure between ortho-positronium and para-positronium is about 203 GHz. We develop a new optical system to accumulate about 10 kW power using a gyrotron, a mode converter, and a Fabry-Pérot cavity. The hyperfine transition has been observed with a significance of 5.4 standard deviations. The transition probability is measured to be $A = 3.1^{+1.6}_{-1.2} \times 10^{-8}$ s$^{-1}$ for the first time, which is in good agreement with the theoretical value of $3.37 \times 10^{-8}$ s$^{-1}$.

hep-ex

First direct measurement of positronium hyperfine splitting with sub-THz light

Positronium is an ideal system for the research of the bound state QED. The hyperfine splitting of positronium (Ps-HFS, about 203 GHz) is an important observable but all previous measurements of Ps-HFS had been measured indirectly using Zeeman splitting. There might be the unknown systematic errors on the uniformity of magnetic field. We are trying to measure Ps-HFS directly using sub-THz radiation. We developed an optical system to accumulate high power (about 10 kW) radiation in a Fabry-Pérot resonant cavity and observed the positronium hyperfine transition for the first time.

hep-ex

Precise measurement of Hyper Fine Structure of positronium using sub-THz light

Positronium is an ideal system for the research of the QED, especially for the QED in bound state. The discrepancy of 3.9σis found recently between the measured HFS values and the QED prediction ($O(α^3)$). It might be due to the contribution of the unknown new physics or the systematic problems in the previous all measurements. We propose new method to measure HFS precisely and directly. A gyrotron, a novel sub-THz light source is used with a high-finesse Fabry-Pérot cavity to obtain enough radiation power at 203 GHz. The present status of the optimization studies and current design of the experiment are described.

hep-ex

Precise measurement of HFS of positronium

The ground state hyperfine splitting in positronium, $Δ_{\mathrm{HFS}}$, is sensitive to high order corrections of QED. A new calculation up to $O(α^3)$ has revealed a $3.9 σ$ discrepancy between the QED prediction and the experimental results. This discrepancy might either be due to systematic problems in the previous experiments or to contributions beyond the Standard Model. We propose an experiment to measure $Δ_{\mathrm{HFS}}$ employing new methods designed to remedy the systematic errors which may have affected the previous experiments. Our experiment will provide an independent check of the discrepancy. The measurement is in progress and a preliminary result of $Δ_{\mathrm{HFS}} = 203.399 \pm 0.029 \mathrm{GHz} (143 \mathrm{ppm})$ has been obtained. A measurement with a precision of O(1) ppm is expected within a few years.

hep-ex

Precision measurements of positronium decay rate and energy level

Positronium is an ideal system for the research of the bound state QED. New precise measurement of orthopositronium decay rate has been performed with an accuracy of 150 ppm, and the result combined with the last three is 7.0401 +- 0.0007 mu s^-1. It is the first result to validate the 2nd order correction. The Hyper Fine Splitting of positronium is sensitive to the higher order corrections of the QED prediction and also to the new physics beyond Standard Model via the quantum oscillation into virtual photon. The discrepancy of 3.5 sigma is found recently between the measured values and the QED prediction (O(alpha^3)). It might be due to the contribution of the new physics or the systematic problems in the previous measurements: (non-thermalized Ps and non-uniformity of the magnetic field). We propose new methods to measure HFS precisely without the these uncertainties.

hep-ex