Searcharxiv⌕ Search

arXiv subjects

T. Iwamoto

Publications and source records attributed to T. Iwamoto.

22 records · Page 2Linked to original sources

New limit on the lepton-flavour violating decay mu -> e gamma

We present a new result based on an analysis of the data collected by the MEG detector at the Paul Scherrer Institut in 2009 and 2010, in search of the lepton flavour violating decay mu->e gamma. The likelihood analysis of the combined data sample, which corresponds to a total of 1.8 x 10**14 muon decays, gives a 90% C.L. upper limit of 2.4 x 10**-12 on the branching ratio of the mu->e gamma decay, constituting the most stringent limit on the existence of this decay to date.

hep-ex↗

A limit for the mu -> e gamma decay from the MEG experiment

A search for the decay mu -> e gamma, performed at PSI and based on data from the initial three months of operation of the MEG experiment, yields an upper limit on the branching ratio of BR(mu -> e gamma) < 2.8 x 10**-11 (90% C.L.). This corresponds to the measurement of positrons and photons from ~ 10**14 stopped mu-decays by means of a superconducting positron spectrometer and a 900 litre liquid xenon photon detector.

hep-ex↗

An Overview of the KamLAND 1-kiloton Liquid Scintillator

KamLAND is a massive liquid-scintillator-based neutrino detector studying low energy neutrino oscillation. The experiment has discovered a large deficit of the reactor neutrino flux with baseline of 180km in the year 2002. This result is placing a strong impact on the elementary particle physics. The KamLAND detector makes use of one kiloton of liquid scintillator (LS) as the active neutrino target. This is the largest homogeneous LS detector in the world. Although the light yield and attenuation length of the LS were measured to be 57% anthracene and ~10m, in the test experiments, when it is used in the KamLAND detector, the effective transparency and light yield significantly increased from these values, presumably due to the scattering and re-emission in the large scale LS. The radio active contamination in the LS is extremely low, such as 3.5E-18g/g for uranium. This is the world's lowest contamination record so far achieved and measured. The success of the KamLAND experiment is a fruit of this high-quality and large-quantity LS. In this proceedings, an outline of the LS is described.

physics.ins-det↗

Diameter dependence of ferromagnetic spin moment in Au nanocrystals

Au nanoparticles exhibit ferromagnetic spin polarization and show diameter dependence in magnetization. The magnetic moment per Au atom in the particle attains its maximum value at a diameter of about 3 nanometer (nm) in the Magnetization-Diameter curve. Because Au metal is a typical diamagnetic material, its ferromagnetic polarization mechanism is thought to be quite different from the ferromagnetism observed in transition metals. The size effect strongly suggests the existence of some spin correlation effect at the nanoscale. The so-called ``Fermi hole effect'' is the most probable one given in the free electron gas system. Ferromagnetism in Au nanoparticles is discussed using this model.

cond-mat.mtrl-sci↗