SearcharxivSearch

arXiv subjects

T. Kishimoto

Publications and source records attributed to T. Kishimoto.

At least 19 recordsLinked to original sources

Probing Internal Conversion and Dark-Matter-Induced De-excitation of 180mTa with a gamma-ray TES Array

We propose and evaluate a source-as-detector search for the de-excitation of the long-lived isomer $^{180\mathrm{m}}\mathrm{Ta}$ in natural tantalum (Ta), using a $\gamma$-ray transition-edge-sensor (TES) array. We exploit two capabilities not available in conventional high-purity germanium (HPGe) searches: (i) near-unity containment of low-energy secondaries (internal-conversion electrons and characteristic X rays), as well as the nuclear recoil, enabling a calorimetric, event-by-event measurement of the total energy deposited in the absorber; and (ii) a delayed-coincidence tag based on the subsequent ${}^{180}$Ta electron-capture (EC) decay to ${}^{180}$Hf. We evaluate the $3\sigma$ discovery reach for internal conversion (IC) and for dark-matter-induced de-excitation in two benchmark scenarios: a strongly interacting dark-matter (DM) subcomponent and inelastic DM with off-diagonal couplings. Using a background model based on intrinsic radioactivity in the Ta absorber and realistic detector performance, we show that arrays with $N_{\mathrm{TES}}=256$ and $1{,}000$ pixels can reach the theoretically expected IC half-life within $2.6$ yr and $0.66$ yr, respectively. For an array with $N_{\mathrm{TES}}=10^4$ and a five-year exposure, the projected sensitivity to DM-induced de-excitation surpasses limits inferred from HPGe non-observations of ${}^{180\mathrm{m}}$Ta and probes regions of parameter space not covered by current direct-detection experiments.

hep-ph

Background stability and annual modulation test using PICOLON ultra-pure NaI(Tl) detector

The dark matter observation claimed by the DAMA/LIBRA experiment has been a long-standing puzzle within the particle physics community. NaI(Tl) crystals with radiopurity comparable to DAMA/LIBRA's are essential for adequate verification. Existing experiments using NaI(Tl) target have been hampered by the high radioactivity concentration of NaI(Tl) crystals. PICOLON experiment conducts an independent search for Weakly Interacting Massive Particles using highest purity NaI(Tl) crystals. In 2020, the NaI(Tl) crystal (Ingot#85) reached the same purity level as DAMA/LIBRA crystals. The DAMA/LIBRA group has stressed that verifying their signal requires high-purity NaI(Tl) crystals with long-term stability. Based on a six-month measurement, we have confirmed the long-term stability of its radiopurity. This stability provides a significant advantage for future efforts to adequately verify the DAMA/LIBRA result using NaI(Tl) crystal. In this paper, we present the background stability of purity in the Ingot#94 NaI(Tl) detector, which was produced using the Ingot#85 purification method, along with the first annual modulation search conducted by the PICOLON experiment.

physics.ins-det

Radiopurity of NaI(Tl) crystals for PICOLON dark matter experiment

The dark matter observation claim by the DAMA/LIBRA collaboration has been a long-standing puzzle within the particle physics community. Efforts of other research groups to verify the claim have been insufficient by significant radioactivity of present NaI(Tl) crystals. PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neut(ra)lino) experiment conducts independent search for Weakly Interacting Massive Particles (WIMPs) using NaI(Tl) crystals. Our NaI(Tl) crystal manufactured in 2020 (Ingot #85) reached the same purity level as DAMA/LIBRA crystals. In this report, we describe the radiopurity of the new Ingot #94 crystal produced using the same purification technique as Ingot #85. The $\alpha$-ray events were selected by pulse-shape discrimination method. The impurities in the Ingot #94, $^{232}$Th, $^{226}$Ra and $^{210}$Po radioactivity were $4.6\pm 1.2~\mathrm{\mu Bq/kg}$, $7.9\pm 4.4~\mathrm{\mu Bq/kg}$, and $19\pm 6~\mathrm{\mu Bq/kg}$, which are equivalent to those of the DAMA/LIBRA crystals. The background rate in the energy region of 2-6 keV , was 2-5 events/d/kg/keV without applying a veto trigger.

physics.ins-det

PICOLON dark matter search project

PICOLON (Pure Inorganic Crystal Observatory for LOw-energy Neutr(al)ino) aims to search for cosmic dark matter by high purity NaI(Tl) scintillator. We developed extremely pure NaI(Tl) crystal by hybrid purification method. The recent result of $^{210}$Pb in our NaI(Tl) is less than 5.7 $μ$Bq/kg. We will report the test experiment in the low-background measurement at Kamioka Underground Laboratory. The sensitivity for annual modulating signals and finding dark matter particles will be discussed.

astro-ph.IM

Low background measurement in CANDLES-III for studying the neutrino-less double beta decay of $^{48}$Ca

We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal backgrounds caused by the radioactive impurities within the CaF$_2$ crystals can be reduced effectively through analysis of the signal pulse shape. We analyzed the data obtained in the Kamioka underground for a live-time of 130.4\,days to evaluate the feasibility of the low background measurement with the CANDLES-III detector. Using Monte Carlo simulations, we estimated the background rate from the radioactive impurities in the CaF$_{2}$ crystals and the rate of high energy $γ$-rays caused by the (n, $γ$) reactions induced by environmental neutrons. The expected background rate was in a good agreement with the measured rate, i.e., approximately 10$^{-3}$ events/keV/yr/(kg of $^{\rm nat.}$Ca), in the 0$νββ$ window. In conclusion, the background candidates were estimated properly by comparing the measured energy spectrum with the background simulations. With this measurement method, we performed the first search for 0$νββ$ decay in a low background condition using a detector with a Ca isotope, in which the Ca present was not enriched, in a scale of hundreds of kg. The $^{48}$Ca isotope has a high potential for use in 0$νββ$ decay search, and is expected to be useful for the development of a next-generation detector for highly sensitive measurements.

hep-ex

A study on energy resolution of CANDLES detector

In a neutrinoless double-beta decay ($0νββ$) experiment, energy resolution is important to distinguish between $0νββ$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0νββ$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value of $^{48}$Ca, the current energy resolution (2.6%) exceeds the ideal statistical fluctuation of the number of photoelectrons (1.6%). Because of CaF$_2$'s long decay constant of 1000 ns, a signal integration within 4000 ns is used to calculate the energy. The baseline fluctuation ($σ_{baseline}$) is accumulated in the signal integration, thus degrading the energy resolution. This paper studies $σ_{baseline}$ in the CANDLES detector, which severely degrades the resolution by 1% at the Q-value of $^{48}$Ca. To avoid $σ_{\rm baseline}$, photon counting can be used to obtain the number of photoelectrons in each PMT; however, a significant photoelectron signal overlapping probability in each PMT causes missing photoelectrons in counting and reduces the energy resolution. "Partial photon counting" reduces $σ_{baseline}$ and minimizes photoelectron loss. We obtain improved energy resolutions of 4.5-4.0% at 1460.8 keV ($γ$-ray of $^{40}$K), and 3.3-2.9% at 2614.5 keV ($γ$-ray of $^{208}$Tl). The energy resolution at the Q-value is estimated to be improved from 2.6% to 2.2%, and the detector sensitivity for the $0νββ$ half-life of $^{48}$Ca can be improved by 1.09 times.

physics.ins-det

The energy calibration system for CANDLES using (n, γ) reaction

CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of a standard high-energy $γ$-ray source. Therefore, we have developed a novel calibration system based on $γ$-ray emission by neutron capture on $^{28}$Si, $^{56}$Fe and $^{58}$Ni nuclei. In the paper, we report the development of the new calibration system as well as the results of energy calibration in CANDLES up to 9 MeV.

physics.ins-det

Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam

We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient background rejection power in Compton-kinematics tests, identifies particle from the energy deposit rate (dE/dX) registered in the TPC, and provides high quality imaging by completely reconstructing the Compton scattering process. We are planning the "Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for observing the Crab nebula, are ongoing. However, observations at balloon altitudes or satellite orbits are obstructed by radiation background from the atmosphere and the detector itself. The background rejection power was checked using proton accelerator experiments conducted at the Research Center for Nuclear Physics, Osaka University. To create the intense radiation fields encountered in space, which comprise gamma rays, neutrons, protons, and other energetic entities, we irradiated a water target with a 140 MeV proton beam and placed a SMILE-II ETCC near the target. In this situation, the counting rate was five times than that expected at the balloon altitude. Nonetheless, the ETCC stably operated and identified particles sufficiently to obtain a clear gamma ray image of the checking source. Here, we report the performance of our detector and demonstrate its effective background rejection based in electron tracking experiments.

astro-ph.IM

The Cherenkov Telescope Array Large Size Telescope

The two arrays of the Very High Energy gamma-ray observatory Cherenkov Telescope Array (CTA) will include four Large Size Telescopes (LSTs) each with a 23 m diameter dish and 28 m focal distance. These telescopes will enable CTA to achieve a low-energy threshold of 20 GeV, which is critical for important studies in astrophysics, astroparticle physics and cosmology. This work presents the key specifications and performance of the current LST design in the light of the CTA scientific objectives.

astro-ph.IM

Development of the Photomultiplier-Tube Readout System for the CTA Large Size Telescope

We have developed a prototype of the photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two thousand PMTs along with their readout systems are arranged on the focal plane of each telescope, with one readout system per 7-PMT cluster. The Cherenkov light pulses generated by the air showers are detected by the PMTs and amplified in a compact, low noise and wide dynamic range gain block. The output of this block is then digitized at a sampling rate of the order of GHz using the Domino Ring Sampler DRS4, an analog memory ASIC developed at Paul Scherrer Institute. The sampler has 1,024 capacitors per channel and four channels are cascaded for increased depth. After a trigger is generated in the system, the charges stored in the capacitors are digitized by an external slow sampling ADC and then transmitted via Gigabit Ethernet. An onboard FPGA controls the DRS4, trigger threshold, and Ethernet transfer. In addition, the control and monitoring of the Cockcroft-Walton circuit that provides high voltage for the 7-PMT cluster are performed by the same FPGA. A prototype named Dragon has been developed that has successfully sampled PMT signals at a rate of 2 GHz, and generated single photoelectron spectra.

astro-ph.IM

Search for a bound state of kaon and pion

We have searched for a bound state of kaon and pion denoted by $X$. The $X$ was conjectured to explain the so-called $Θ^+$ resonance as a bound state of kaon, pion and nucleon. This model explains almost all properties of the $Θ^+$, however, the model works only if the $K π$ interaction is strongly attractive. It is so strong that it could make a bound state $X$. Here we report a result of the search for the $X$ by using the $K^+ + N \rightarrow X^+ + N$ reaction at P$_K\sim$ 1.2 GeV/c. The $X^+ \rightarrow K^+ γγ$ decay produces $K^+$ in momentum region where other processes cannot fill. We observed signature of the $X^+$ with statistical significance of 2 $σ$. Production cross section of $X$ with respect to that of $π^0$ is 1$\pm$0.5% if we take it as an evidence and 1.5% if we set an upper limit.

hep-ex

Coherent transfer of photoassociated molecules into the rovibrational ground state

We report on the direct conversion of laser-cooled 41K and 87Rb atoms into ultracold 41K87Rb molecules in the rovibrational ground state via photoassociation followed by stimulated Raman adiabatic passage. High-resolution spectroscopy based on the coherent transfer revealed the hyperfine structure of weakly bound molecules in an unexplored region. Our results show that a rovibrationally pure sample of ultracold ground-state molecules is achieved via the all-optical association of laser-cooled atoms, opening possibilities to coherently manipulate a wide variety of molecules.

physics.atom-ph

Production of Neutron-Rich Lambda Hypernuclei at J-PARC

We discuss the usefulness of the double charge-exchange reactions (DCX) for the production of the neutron-rich Lambda-hypernuclei. We believe the (pi-,K+) reaction is one of the most promising DCX reactions, and propose to produce the neutron-rich Lambda-hypernuclei, 6(Lambda)H and 9(Lambda)He, at the J-PARC 50 GeV PS by the reaction (J-PARC E10 experiment). The design of the experiment is presented.

nucl-ex

Direct evaporative cooling of 41K into a Bose-Einstein condensate

We have investigated the collisional properties of 41K atoms at ultracold temperature. To show the possibility to use 41K as a coolant, a Bose-Einstein condensate of 41K atoms in the stretched state (F=2, m_F=2) was created for the first time by direct evaporation in a magnetic trap. An upper bound of three body loss coefficient for atoms in the condensate was determined to be 4(2) 10^{-29} cm -6 s-1. A Feshbach resonance in the F=1, m_F=-1 state was observed at 51.42(5) G, which is in good agreement with theoretical prediction.

physics.atom-ph

Neutrino-less Double Beta Decay of 48Ca studied by CaF2(Eu) Scintillators

We searched for the neutrino-less double beta decay(0nbb) of 48Ca by using CaF2(Eu) scintillators. Analysis of their pulse shapes was effective to reduce backgrounds. No events are observed in the Q-value region for the data of 3394 kg days. It gives a lower limit (90% confidence level) of T > 2.7 x 10^22 year for the half life of 0nbb of 48Ca. Combined with our previous data for 1553 kg days, we obtained more stringent limit of T > 5.8 x 10^22 year.

nucl-ex

Challenge on Ca-48 enrichment for CANDLES double beta decay experiment

Chemical isotope effects of calcium were studied by liquid-liquid extraction using a crown ether of dicyclohexano-18-crown-6 for the purpose of finding a cost-effective and efficient way of enrichment of Ca-48 towards the study of the neutrinoless double beta decay of Ca-48. We evaluated each contribution ratio of the field shift effect and the hyperfine splitting shift effect to the mass effect of the calcium isotopes for the first time. The present preliminary result suggests the contribution of the field shift effect is small, especially for Ca-40-Ca-48 case, compared with the case of Chromium trichloride-crown in which the isotope enrichment factors are strongly affected by the field shifts. These indications are promising towards the mass producion of enriched Ca-48 by the chemical separation method.

nucl-ex

Electrodynamic trapping of spinless neutral atoms with an atom chip

Three dimensional electrodynamic trapping of neutral atoms has been demonstrated. By applying time-varying inhomogeneous electric fields with micron-sized electrodes, nearly $10^2$ strontium atoms in the $^1S_0$ state have been trapped with a lifetime of 80 ms. In order to design the electrodes, we numerically analyzed the electric field and simulated atomic trajectories in the trap, which showed reasonable agreement with the experiment.

physics.atom-ph

Mesonic and nonmesonic weak decay widths of medium-heavy lambda hypernuclei

We have measured the energy spectra of pions and protons emitted in the weak decay of 12_Lambda_C, 28_Lambda_Si, and Lambda_Fe hypernuclei produced via the (pi+, K+) reaction. The decay widths of the pi- mesonic decay (Lambda -> p + pi-) and the nonmesonic decay (Lambda + N -> N + N) were extracted. The present results demonstrate an increase of the mesonic decay width due to a distortion of the pion wave function in nuclear medium for the first time. The ratios of the neutron- to proton-induced nonmesonic decay widths, Gamma_n(Lambda + n -> n + n)/Gamma_p(Lambda + p -> n + p), were evaluated by a direct comparison of the measured proton energy spectra with the calculated ones. No theoretical calculation which has been proposed so far can simultaneously account for both the nonmesonic decay widths and the Gamma_n/Gamma_p ratios in the present data.

nucl-ex