SearcharxivSearch

arXiv subjects

T. Kozik

Publications and source records attributed to T. Kozik.

At least 19 recordsLinked to original sources

Measurement of the forward angle $^{12}$C+$^{12}$C fragmentation differential cross sections at 62 MeV/nucleon

The present work reports on high-precision measurements of forward-angle fragmentation differential cross sections for the [12]C +[12] C reaction at 62 MeV/nucleon using the FAZIA array. Angular distributions for fragments from Z = 1 to 6 were extracted in the range 2 <= theta_lab <= 8 degrees. Particle identification was achieved by combining the Delta E - E technique with Pulse Shape Analysis, and precise energy calibrations were performed. The results show that for heavier fragments, the angular distributions are better described by the Van Bibber formulation than by the Goldhaber model, consistent with the dominance of a wide component from dissipative processes in the measured angular range. Notably, alpha particles exhibit an anomalously narrow angular distribution, likely originating from the intrinsic cluster structure of [12]C. Comparisons with existing data at the same incident energy show very good agreement, with a more complete set of species reported here, while a kinematic scaling is proposed to compare our data with previous experimental data at 50 and 95 MeV/nucleon.

nucl-ex

Studies of CPT symmetry in positronium decays with 192 plastic strip J-PET detector

A direct test of the CPT symmetry is performed for the electromagnetic decays of ortho-positronium using the J-PET tomograph. We present the precise measurement of the CPT-sensitive angular correlation entailing the positronium spin and the momenta of its annihilation photons, surpassing previous studies utilizing the same detection system. Positrons originating from a $^{22}$Na source are emitted from the detector's center and subsequently form positronium atoms within the spherical chamber covered with porous material. Reconstruction of annihilation locations using the 192-strip J-PET detector makes it possible to determine the positronium emission direction, which defines the quantization axis along which positronium is polarized, without the application of external magnetic fields. The measurements were performed in total for 356 days resulting in an identification of 47.8 million events with ortho-positronium decays into three photons. The results are consistent with the exactness of CPT symmetry with measured asymmetry amplitude -0.00029 $\pm$ 0.00022 (stat.) and with statistical error four times smaller than the previous best measurement.

nucl-ex

Model-independent measurement of isospin diffusion in Ni-Ni systems at intermediate energy

In this work we provide a model-independent experimental evaluation of the degree of isospin equilibration taking place in $^{58,64}$Ni+$^{58,64}$Ni collisions at 32 MeV/nucleon across varying reaction centralities. This result has been obtained by combining the complementary information provided by two different datasets, sharing common characteristics. The first dataset has been acquired with the INDRA setup and has been used to implement a model-independent reconstruction of the impact parameter. The second dataset has been acquired in the first experimental campaign of the coupled INDRA-FAZIA apparatus at GANIL. The neutron-to-proton content of the quasiprojectile remnant measured by FAZIA has been employed as isospin observable. The effect of isospin diffusion has been evidenced by means of the isospin transport ratio, reported as a function of the impact parameter of the collision. The evolution towards isospin equilibration from semiperipheral to more central collisions is clearly extracted. This experimental result, expanding our previous works (Phys. Rev. C 106, 024603 (2022) and Phys. Rev. C 108, 054611 (2023)), can be compared with the predictions of any transport model, and can thus be used to set constraints on the behavior of the symmetry energy term of the nuclear Equation of State at sub- to saturation densities.

nucl-ex

Nanoporosity imaging by positronium lifetime tomography

Positron Annihilation Lifetime Spectroscopy (PALS) is a well-established non-destructive technique used for nanostructural characterization of porous materials. It is based on the annihilation of a positron and an electron. Mean positron lifetime in the material depends on the free voids size and molecular environment, allowing the study of porosity and structural transitions in the nanometer scale. We have developed a novel method enabling spatially resolved PALS, thus providing tomography of nanostructural characterization of an extended object. Correlating space (position) and structural (lifetime) information brings new insight in materials studies, especially in the characterization of the purity and pore distribution. For the first time, a porosity image using stationary positron sources for the simultaneous measurement of the porous polymers XAD4, silica aerogel powder IC3100, and polyvinyl toluene scintillator PVT by the J-PET tomograph is demonstrated

physics.app-ph

Investigation of Novel Preclinical Total Body PET Designed With J-PET Technology:A Simulation Study

The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring, animal-based research became a necessary step for testing and protocol preparation. In this simulation-based study two unconventional, cost-effective small animal total body PET scanners (for mouse and rat studies) have been investigated in order to inspect their feasibility for preclinical research. They were designed with the novel technology explored by the Jagiellonian-PET (J-PET) Collaboration. Two main PET characteristics: sensitivity and spatial resolution were mainly inspected to evaluate their performance. Moreover, the impact of the scintillator dimension and time-of-flight on the latter parameter was examined in order to design the most efficient tomographs. The presented results show that for mouse TB J-PET the achievable system sensitivity is equal to 2.35% and volumetric spatial resolution to 9.46 +- 0.54 mm3, while for rat TB J-PET they are equal to 2.6% and 14.11 +- 0.80 mm3, respectively. Furthermore, it was shown that the designed tomographs are almost parallax-free systems, hence, they resolve the problem of the acceptance criterion tradeoff between enhancing spatial resolution and reducing sensitivity.

physics.med-ph

Comparative studies of plastic scintillator strips with high technical attenuation length for the total-body J-PET scanner

Plastic scintillator strips are considered as one of the promising solutions for the cost-effective construction of total-body positron emission tomography, (PET) system. The purpose of the performed measurements is to compare the transparency of long plastic scintillators with dimensions 6 mm x 24 mm x 1000 mm and with all surfaces polished. Six different types of commercial, general purpose, blue-emitting plastic scintillators with low attenuation of visible light were tested, namely: polyvinyl toluene-based BC-408, EJ-200, RP-408, and polystyrene-based Epic, SP32 and UPS-923A. For determination of the best type of plastic scintillator for totalbody Jagiellonian positron emission tomograph (TB-J-PET) construction, emission and transmission spectra, and technical attenuation length (TAL) of blue light-emitting by the scintillators were measured and compared. The TAL values were determined with the use of UV lamp as excitation source, and photodiode as light detector. Emission spectra of investigated scintillators have maxima in the range from 420 nm to 429 nm. The BC-408 and EJ-200 have the highest transmittance values of about 90% at the maximum emission wavelength measured through a 6 mm thick scintillator strip and the highest technical attenuation length reaching about 2000 mm, allowing assembly of long detection modules for time-of-flight (TOF) J-PET scanners. Influence of the 6 mm x 6 mm, 12 mm x 6 mm, 24 mm x 6 mm cross-sections of the 1000 mm long EJ-200 plastic scintillator on the TAL and signal intensity was measured. The highest TAL value was determined for samples with 24 mm x 6 mm cross-section.

physics.ins-det

Non-maximal entanglement of photons from positron-electron annihilation demonstrated using a novel plastic PET scanner

In state-of-the-art Positron Emission Tomography (PET), information about annihilation photon polarization is unavailable. Here, we present a PET scanner built from plastic scintillators, where annihilation photons primarily interact via the Compton effect, providing information about both photon polarization and propagation direction. Using this plastic-based PET, we determined the distribution of the relative angle between polarization planes of photons from positron-electron annihilation in a porous polymer. The amplitude of the observed distribution is smaller than predicted for maximally quantum-entangled two-photon states but larger than expected for separable photons. This result can be well explained by assuming that photons from pick-off annihilation are not entangled, while photons from direct and para-positronium annihilations are maximally entangled. Our result indicates that the degree of entanglement depends on the annihilation mechanism in matter, opening new avenues for exploring polarization correlations in PET as a diagnostic indicator.

nucl-ex

Study of quasi-projectile properties at Fermi energies in 48Ca projectile systems

The emission of the pre-equilibrium particles during nuclear collisions at moderate beam energies is still an open question. This influences the properties of the compound nucleus but also changes the interpretation of the quasi-fission process. A systematic analysis of the data obtained by the FAZIA collaboration during a recent experiment with a neutron rich projectile is presented. The full range of charged particles detected in the experiment is within the limit of isotopic resolution of the FAZIA detector. Quasi-projectile (QP) fragments were detected in majority thanks to the forward angular acceptance of the experimental setup which was confirmed by introducing cuts based on the HIPSE event generator calculations. The main goal was to compare the experimental results with the HIPSE simulations after introducing these cuts to investigate the influence of the n-rich entrance channel on the QP fragment properties. More specifically, the lowering of N/Z of QP fragments with beam energy was found to be present since the initial phase of the reaction. Thus, pre-equilibrium emissions might be a possible candidate to explain such an effect.

nucl-ex

Isospin diffusion from $^{40,48}$Ca$+^{40,48}$Ca experimental data at Fermi energies: Direct comparisons with transport model calculations

This article presents an investigation of isospin equilibration in cross-bombarding $^{40,48}$Ca$+^{40,48}$Ca reactions at 35 MeV/nucleon, by comparing experimental data with filtered transport model calculations. Isospin diffusion is studied using the evolution of the isospin transport ratio with centrality. The asymmetry parameter $\delta=(N-Z)/A$ of the quasiprojectile (QP) residue is used as isospin-sensitive observable, while a recent method for impact parameter reconstruction is used for centrality sorting. A benchmark of global observables is proposed to assess the relevance of the antisymmetrized molecular dynamics (AMD) model, coupled to GEMINI++, in the study of dissipative collisions. Our results demonstrate the importance of considering cluster formation to reproduce observables used for isospin transport and centrality studies. Within the AMD model, we prove the applicability of the impact parameter reconstruction method, enabling a direct comparison to the experimental data for the investigation of isospin diffusion. For both, we evidence a tendency to isospin equilibration with an impact parameter decreasing from 9 to 3 fm, while the full equilibration is not reached. A weak sensitivity to the stiffness of the equation of state employed in the model is also observed, with a better reproduction of the experimental trend for the neutron-rich reactions.

nucl-ex

Feasibility studies for imaging e$^{+}$e$^{-}$ annihilation with modular multi-strip detectors

Studies based on imaging the annihilation of the electron (e$^{-}$) and its antiparticle positron (e$^{+}$) open up several interesting applications in nuclear medicine and fundamental research. The annihilation process involves both the direct conversion of e$^{+}$e$^{-}$ into photons and the formation of their atomically bound state, the positronium atom (Ps), which can be used as a probe for fundamental studies. With the ability to produce large quantities of Ps, manipulate them in long-lived Ps states, and image their annihilations after a free fall or after passing through atomic interferometers, this purely leptonic antimatter system can be used to perform inertial sensing studies in view of a direct test of Einstein equivalence principle. It is envisioned that modular multistrip detectors can be exploited as potential detection units for this kind of studies. In this work, we report the results of the first feasibility study performed on a e$^{+}$ beamline using two detection modules to evaluate their reconstruction performance and spatial resolution for imaging e$^{+}$e$^{-}$ annihilations and thus their applicability for gravitational studies of Ps.

physics.ins-det

Quasiprojectile breakup and isospin equilibration at Fermi energies: an indication of longer projectile-target contact times?

An investigation of the quasiprojectile breakup channel in semiperipheral and peripheral collisions of $^{58,64}$Ni+$^{58,64}$Ni at 32 and 52 MeV/nucleon is presented. Data have been acquired in the first experimental campaign of the INDRA-FAZIA apparatus in GANIL. The effect of isospin diffusion between projectile and target in the two asymmetric reactions has been highlighted by means of the isospin transport ratio technique, exploiting the neutron-to-proton ratio of the quasiprojectile reconstructed from the two breakup fragments. We found evidence that, for the same reaction centrality, a higher degree of relaxation of the initial isospin imbalance is achieved in the breakup channel with respect to the more populated binary output, possibly indicating the indirect selection of specific dynamical features. We have proposed an interpretation based on different average projectile-target contact times related to the two exit channels under investigation, with a longer interaction for the breakup channel. The time information has been extracted from AMD simulations of the studied systems coupled to GEMINI++: the model calculations support the hypothesis hereby presented.

nucl-ex

Examination of cluster production in excited light systems at Fermi energies from new experimental data and comparison with transport model calculations

Four different reactions, $^{32}$S+$^{12}$C and $^{20}$Ne+$^{12}$C at 25 and 50 MeV/nucleon, have been measured with the FAZIA detector capable of full isotopic identification of most forward emitted reaction products. Fragment multiplicities, angular distributions and energy spectra have been measured and compared with Monte Carlo simulations, i.e. the antisymmetrized molecular dynamics (AMD) and the heavy-ion phase space exploration (HIPSE) models. These models are combined with two different afterburner codes (HF$l$ and SIMON) to describe the decay of the excited primary fragments. In the case of AMD, the effect of including the clustering and inter-clustering processes to form bound particles and fragments is discussed. A clear confirmation of the role of cluster aggregation in the reaction dynamics and particle production for these light systems, for which the importance of the clustering process increases with bombarding energy, is obtained.

nucl-ex

Characterization of the breakup channel in the asymmetric systems $^{40,48}$Ca+$^{12}$C at 25 and 40 MeV/nucleon

An analysis of the asymmetric reactions $^{40,48}$Ca+$^{12}$C at 25 and 40 MeV/nucleon is presented. Data have been collected with six modules of the FAZIA array. The analysis is focused on the breakup channel of sources produced in dissipative collisions, partially corresponding to incomplete fusion processes. The study has been performed both on detected fragments and on some resonances reconstructed by means of particle-fragment correlations, with a focus on the evolution of the breakup channel with the beam energy and the neutron content of the system, looking in particular at the relative velocity between the breakup fragments. Results show that also Carbon fragments reconstructed by means of particle correlations can be in large part interpreted as the light partner of a scission.

nucl-ex

TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix

We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.

physics.med-ph

J-PET detection modules based on plastic scintillators for performing studies with positron and positronium beams

The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 plastic scintillators arranged in 3 layers has been optimized for the study of positronium decays. This allows performing precision tests of discrete symmetries (C, P, T) in the decays of positronium atoms. Moreover, thanks to the possibility of measuring the polarization direction of the photon based on Compton scattering, the predicted entanglement between the linear polarization of annihilation photons in positronium decays can also be studied. Recently, a new J-PET prototype was commissioned, based on a modular design of detection units. Each module consists of 13 plastic scintillators and can be used as a stand-alone, compact and portable detection unit. In this paper, the main features of the J-PET detector, the modular prototype and their applications for possible studies with positron and positronium beams are discussed. Preliminary results of the first test experiment performed on two detection units in the continuous positron beam recently developed at the Antimatter Laboratory (AML) of Trento are also reported.

physics.ins-det

First results from the INDRA-FAZIA apparatus on isospin diffusion in $^{58,64}$Ni+$^{58,64}$Ni systems at Fermi energies

An investigation of the isospin equilibration process in the reactions $^{58,64}$Ni+$^{58,64}$Ni at two bombarding energies in the Fermi regime ($32\,$MeV/nucleon and $52\,$MeV/nucleon) is presented. Data have been acquired during the first experimental campaign of the coupled INDRA-FAZIA apparatus in GANIL. Selecting from peripheral to semi-central collisions, both the neutron content of the quasiprojectile residue and that of the light ejectiles coming from the quasiprojectile evaporation have been used as probes of the dynamical process of isospin diffusion between projectile and target for the asymmetric systems. The isospin transport ratio technique has been employed. The relaxation of the initial isospin imbalance with increasing centrality has been clearly evidenced. The isospin equilibration appears stronger for the reactions at $32\,$MeV/nucleon, as expected due to the longer projectile-target interaction time than at $52\,$MeV/nucleon. Coherent indications of isospin equilibration come from the quasiprojectile residue characteristics and from particles ascribed to the quasiprojectile decay.

nucl-ex

The J-PET detector -- a tool for precision studies of ortho-positronium decays

The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events is based on the measurement of the photons energies. In this article we show that the J-PET tomograph system is capable of exclusive measurements of the decays of ortho-positronium atoms. We present the first positronium production results, its lifetime distribution measurements and discuss estimation of the influence of various background sources. The tomograph s performance demonstrated here makes it suitable for precision studies of positronium decays including entanglement of the final state photons, positron annihilation lifetime spectroscopy plus molecular imaging diagnostics.

physics.ins-det

Dynamical fission of the quasiprojectile and isospin equilibration for the system 80Kr+ 48 Ca at 35 MeV/nucleon

Experimental results concerning the dynamical fission of quasiprojectiles in semiperipheral collisions for the system 80 Kr+ 48 Ca at 35 MeV/nucleon are presented. Data have been collected with four blocks of the FAZIA setup in the first physics experiment of the FAZIA Collaboration. The degree of isospin equilibration between the two fission fragments and its dependence on their charge asymmetry is investigated. The data are compared with the results of the AMD model coupled to GEMINI as an afterburner, in order to get hints about the timescale of the process.

nucl-ex