SearcharxivSearch

arXiv subjects

T. M. Fortier

Publications and source records attributed to T. M. Fortier.

18 recordsLinked to original sources

Radio Frequency from Optical with Instabilities below $10^{-15}$- Generation and Measurement

This paper presents a frequency synthesis that achieves exceptional stability by transferring optical signals to the radio frequency (RF) domain at 100 MHz. We describe and characterize two synthesis chains composed of a cryogenic silicon cavity-stabilized laser at 1542 nm and an ultra-low expansion (ULE) glass cavity at 1157 nm, both converted to 10 GHz signals via Ti:Sapphire and Er/Yb:glass optical frequency combs (OFCs). The 10 GHz microwave outputs are further divided down to 100 MHz using a commercial microwave prescaler, which exhibits a residual frequency instability of $σ_y(1~\text{s})<10^{-15}$ and low $10^{-18}$ level at a few thousand seconds. Measurements are performed using a newly developed custom ultra-low-noise digital measurement system and are compared to the carrier-suppression technique. The new system enables high-sensitivity evaluation across the entire synthesis chain, from the optical and microwave heterodynes as well as the direct RF signals. Results show an absolute instability of $σ_y(1~\text{s})~\approx~4.7\times10^{-16}$ at 100 MHz. This represents the first demonstration of such low instability at 100 MHz, corresponding to a phase noise of -140 dBc/Hz at a 1 Hz offset and significantly surpassing earlier systems. These advancements open new opportunities for precision metrology and timing systems.

physics.optics

Measurements of $^{27}$Al$^{+}$ and $^{25}$Mg$^{+}$ magnetic constants for improved ion clock accuracy

We have measured the quadratic Zeeman coefficient for the ${^{1}S_{0} \leftrightarrow {^{3}P_{0}}}$ optical clock transition in $^{27}$Al$^{+}$, $C_{2}=-71.944(24)$~MHz/T$^{2}$, and the unperturbed hyperfine splitting of the $^{25}$Mg$^{+}$ $^{2}S_{1/2}$ ground electronic state, $ΔW / h = 1~788~762~752.85(13)$~Hz, with improved uncertainties. Both constants are relevant to the evaluation of the $^{27}$Al$^{+}$ quantum-logic clock systematic uncertainty. The measurement of $C_{2}$ is in agreement with a previous measurement and a new calculation at the $1~σ$ level. The measurement of $ΔW$ is in good agreement with a recent measurement and differs from a previously published result by approximately $2σ$. With the improved value for $ΔW$, we deduce an improved value for the nuclear-to-electronic g-factor ratio $g_{I}/g_{J} = 9.299 ~308 ~313(60) \times 10^{-5}$ and the nuclear g-factor for the $^{25}$Mg nucleus $g_{I} = 1.861 ~957 ~82(28) \times 10^{-4}$. Using the values of $C_{2}$ and $ΔW$ presented here, we derive a quadratic Zeeman shift of the $^{27}$Al$^{+}$ quantum-logic clock of $Δν/ ν= -(9241.8 \pm 3.7) \times 10^{-19}$, for a bias magnetic field of $B \approx 0.12$~mT.

physics.atom-ph

Towards Adoption of an Optical Second: Verifying Optical Clocks at the SI Limit

The pursuit of ever more precise measures of time and frequency is likely to lead to the eventual redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on a microwave transition between hyperfine levels in ground-state $^{133}$Cs, it is necessary to measure the absolute frequency of candidate standards, which is done by comparing against a primary cesium reference. A key verification of this process can be achieved by performing a loop closure$-$comparing frequency ratios derived from absolute frequency measurements against ratios determined from direct optical comparisons. We measure the $^1$S$_0\!\rightarrow^3$P$_0$ transition of $^{171}$Yb by comparing the clock frequency to an international frequency standard with the aid of a maser ensemble serving as a flywheel oscillator. Our measurements consist of 79 separate runs spanning eight months, and we determine the absolute frequency to be 518 295 836 590 863.71(11) Hz, the uncertainty of which is equivalent to a fractional frequency of $2.1\times10^{-16}$. This absolute frequency measurement, the most accurate reported for any transition, allows us to close the Cs-Yb-Sr-Cs frequency measurement loop at an uncertainty of $<$3$\times10^{-16}$, limited by the current realization of the SI second. We use these measurements to tighten the constraints on variation of the electron-to-proton mass ratio, $μ=m_e/m_p$. Incorporating our measurements with the entire record of Yb and Sr absolute frequency measurements, we infer a coupling coefficient to gravitational potential of $k_\mathrmμ=(-1.9\pm 9.4)\times10^{-7}$ and a drift with respect to time of $\frac{\dotμ}μ=(5.3 \pm 6.5)\times10^{-17}/$yr.

physics.atom-ph

Optimizing the linearity in high-speed photodiodes

Analog photonic links require high-fidelity, high-speed optical-to-electrical conversion for applications such as radio-over-fiber, synchronization at kilometer-scale facilities, and low-noise electronic signal generation. Photodetector nonlinearity is a particularly vexing problem, causing signal distortion and excess noise, especially in systems utilizing ultrashort optical pulses. Here we show that photodetectors designed for high power handling and high linearity can perform optical-to-electrical conversion of ultrashort optical pulses with unprecedented linearity over a large photocurrent range. We also show that the broadband, complex impedance of the circuit following the photodiode modifies the linearity significantly. By externally manipulating the circuit impedance, we extend the detector's linear range to higher photocurrents, with over 50 dB rejection of amplitude-to-phase conversion for photocurrents up to 40 mA. This represents a 1000-fold improvement over state-of-the-art photodiodes and significantly extends the attainable microwave power by a factor of four. As such, we eliminate the long-standing requirement in ultrashort pulse detection of precise tuning of the photodiode's operating parameters (average photocurrent, bias voltage or temperature) to coincide with a nonlinearity minimum. These results should also apply more generally to reduce nonlinear distortion in a range of other microwave photonics applications.

physics.ins-det

Hyperpolarizability and operational magic wavelength in an optical lattice clock

Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an $^{171}$Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the $10^{-18}$ level and beyond.

physics.atom-ph

A compact, thermal noise limited reference cavity for ultra-low noise microwave generation

We demonstrate an easy to manufacture, 25 mm long ultra-stable optical reference cavity for transportable photonic microwave generation systems. Employing a rigid holding geometry that is first-order insensitive to the squeezing force and a cavity geometry that improves the thermal noise limit at room temperature, we observe a laser phase noise that is nearly thermal noise limited for three frequency decades (1 Hz to 1 kHz offset) and supports 10 GHz generation with phase noise near -100 dBc/Hz at 1 Hz offset and <-173 dBc/Hz for all offsets >600 Hz. The fractional frequency stability reaches $2\times10^{-15}$ at 0.1 s of averaging.

physics.ins-det

Digital-photonic synthesis of ultra-low noise tunable signals from RF to 100 GHz

The demand for higher data rates and better synchronization in communication and navigation systems necessitates the development of new wideband and tunable sources with noise performance exceeding that provided by traditional oscillators and synthesizers. Precision synthesis is paramount for providing frequency references and timing in a broad range of applications including next-generation telecommunications, high precision measurement, and radar and sensing. Here we describe a digital-photonic synthesizer (DPS) based on optical frequency division that enables the generation of widely tunable signals from near DC to 100 GHz with a fractional frequency instability of 1 part in 10^15. The spectral purity of the DPS derived signals represents an improvement in close-to-carrier noise performance over the current state-of-the-art of nearly 7 orders of magnitude in the W-band (100 GHz), and up to 5 orders of magnitude in the X-band (10 GHz).

physics.ins-det

Ultralow phase noise microwave generation with an Er:fiber-based optical frequency divider

We present an optical frequency divider based on a 200 MHz repetition rate Er:fiber mode-locked laser that, when locked to a stable optical frequency reference, generates microwave signals with absolute phase noise that is equal to or better than cryogenic microwave oscillators. At 1 Hz offset from a 10 GHz carrier, the phase noise is below -100 dBc/Hz, limited by the optical reference. For offset frequencies > 10 kHz, the phase noise is shot noise limited at -145 dBc/Hz. An analysis of the contribution of the residual noise from the Er:fiber optical frequency divider is also presented.

physics.optics

Generation of Ultrastable Microwaves via Optical Frequency Division

There has been increased interest in the use and manipulation of optical fields to address challenging problems that have traditionally been approached with microwave electronics. Some examples that benefit from the low transmission loss, agile modulation and large bandwidths accessible with coherent optical systems include signal distribution, arbitrary waveform generation, and novel imaging. We extend these advantages to demonstrate a microwave generator based on a high-Q optical resonator and a frequency comb functioning as an optical-to-microwave divider. This provides a 10 GHz electrical signal with fractional frequency instability <8e-16 at 1 s, a value comparable to that produced by the best microwave oscillators, but without the need for cryogenic temperatures. Such a low-noise source can benefit radar systems, improve the bandwidth and resolution of communications and digital sampling systems, and be valuable for large baseline interferometry, precision spectroscopy and the realization of atomic time.

physics.optics

Spin-1/2 Optical Lattice Clock

We experimentally investigate an optical clock based on $^{171}$Yb ($I=1/2$) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of $3.4 \times 10^{-16}$, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.

physics.atom-ph

Frequency evaluation of the doubly forbidden $^1S_0\to ^3P_0$ transition in bosonic $^{174}$Yb

We report an uncertainty evaluation of an optical lattice clock based on the $^1S_0\leftrightarrow^3P_0$ transition in the bosonic isotope $^{174}$Yb by use of magnetically induced spectroscopy. The absolute frequency of the $^1S_0\leftrightarrow^3P_0$ transition has been determined through comparisons with optical and microwave standards at NIST. The weighted mean of the evaluations is $ν$($^{174}$Yb)=518 294 025 309 217.8(0.9) Hz. The uncertainty due to systematic effects has been reduced to less than 0.8 Hz, which represents $1.5\times10^{-15}$ in fractional frequency.

physics.atom-ph

Sr lattice clock at 1x10^{-16} fractional uncertainty by remote optical evaluation with a Ca clock

Optical atomic clocks promise timekeeping at the highest precision and accuracy, owing to their high operating frequencies. Rigorous evaluations of these clocks require direct comparisons between them. We have realized a high-performance remote comparison of optical clocks over km-scale urban distances, a key step for development, dissemination, and application of these optical standards. Through this remote comparison and a proper design of lattice-confined neutral atoms for clock operation, we evaluate the uncertainty of a strontium (Sr) optical lattice clock at the 1x10-16 fractional level, surpassing the best current evaluations of cesium (Cs) primary standards. We also report on the observation of density-dependent effects in the spin-polarized fermionic sample and discuss the current limiting effect of blackbody radiation-induced frequency shifts.

physics.atom-ph

Optical Lattice Induced Light Shifts in an Yb Atomic Clock

We present an experimental study of the lattice induced light shifts on the 1S_0-3P_0 optical clock transition (v_clock~518 THz) in neutral ytterbium. The ``magic'' frequency, v_magic, for the 174Yb isotope was determined to be 394 799 475(35)MHz, which leads to a first order light shift uncertainty of 0.38 Hz on the 518 THz clock transition. Also investigated were the hyperpolarizability shifts due to the nearby 6s6p 3P_0 - 6s8p 3P_0, 6s8p 3P_2, and 6s5f 3F_2 two-photon resonances at 759.708 nm, 754.23 nm, and 764.95 nm respectively. By tuning the lattice frequency over the two-photon resonances and measuring the corresponding clock transition shifts, the hyperpolarizability shift was estimated to be 170(33) mHz for a linear polarized, 50 uK deep, lattice at the magic wavelength. In addition, we have confirmed that a circularly polarized lattice eliminates the J=0 - J=0 two-photon resonance. These results indicate that the differential polarizability and hyperpolarizability frequency shift uncertainties in a Yb lattice clock could be held to well below 10^-17.

physics.atom-ph

Observation of the 1S0 - 3P0 clock transition in 27Al+

We report for the first time, laser spectroscopy of the 1S0 - 3P0 clock transition in 27Al+. A single aluminum ion and a single beryllium ion are simultaneously confined in a linear Paul trap, coupled by their mutual Coulomb repulsion. This coupling allows the beryllium ion to sympathetically cool the aluminum ion, and also enables transfer of the aluminum's electronic state to the beryllium's hyperfine state, which can be measured with high fidelity. These techniques are applied to a measurement of the clock transition frequency, ν= 1 121 015 393 207 851(8) Hz. They are also used to measure the lifetime of the metastable clock state, τ= 20.6 +/- 1.4 s, the ground state 1S0 g-factor, g_S = -0.00079248(14), and the excited state 3P0 g-factor, g_P = -0.00197686(21), in units of the Bohr magneton.

physics.atom-ph

Measurement of excited-state transitions in cold calcium atoms by direct femtosecond frequency-comb spectroscopy

We apply direct frequency-comb spectroscopy, in combination with precision cw spectroscopy, to measure the ${\rm 4s4p} ^3P_1 \to {\rm 4s5s} ^3S_1$ transition frequency in cold calcium atoms. A 657 nm ultrastable cw laser was used to excite atoms on the narrow ($γ\sim 400$ Hz) ${\rm 4s^2} ^1S_0 \to {\rm 4s4p} ^3P_1$ clock transition, and the direct output of the frequency comb was used to excite those atoms from the ${\rm 4s4p} ^3P_1$ state to the ${\rm 4s5s} ^3S_1$ state. The resonance of this second stage was detected by observing a decrease in population of the ground state as a result of atoms being optically pumped to the metastable ${\rm 4s4p} ^3P_{0,2}$ states. The ${\rm 4s4p} ^3P_1 \to {\rm 4s5s} ^3S_1$ transition frequency is measured to be $ν= 489 544 285 713(56)$ kHz; which is an improvement by almost four orders of magnitude over the previously measured value. In addition, we demonstrate spectroscopy on magnetically trapped atoms in the ${\rm 4s4p} ^3P_2$ state.

physics.atom-ph

Kilohertz-resolution spectroscopy of cold atoms with an optical frequency comb

We have performed sub-Doppler spectroscopy on the narrow intercombination line of cold calcium atoms using the amplified output of a femtosecond laser frequency comb. Injection locking of a 657-nm diode laser with a femtosecond comb allows for two regimes of amplification, one in which many lines of the comb are amplified, and one where a single line is predominantly amplified. The output of the laser in both regimes was used to perform kilohertz-level spectroscopy. This experiment demonstrates the potential for high-resolution absolute-frequency spectroscopy over the entire spectrum of the frequency comb output using a single high-finesse optical reference cavity.

physics.atom-ph

Observation and absolute frequency measurements of the 1S0 - 3P0 optical clock transition in ytterbium

We report the direct excitation of the highly forbidden (6s^2) 1S0 - (6s6p) 3P0 optical transition in two odd isotopes of ytterbium. As the excitation laser frequency is scanned, absorption is detected by monitoring the depletion from an atomic cloud at ~70 uK in a magneto-optical trap. The measured frequency in 171Yb (F=1/2) is 518,295,836,593.2 +/- 4.4 kHz. The measured frequency in 173Yb (F=5/2) is 518,294,576,850.0 +/- 4.4 kHz. Measurements are made with a femtosecond-laser frequency comb calibrated by the NIST cesium fountain clock and represent nearly a million-fold reduction in uncertainty. The natural linewidth of these J=0 to J=0 transitions is calculated to be ~10 mHz, making them well-suited to support a new generation of optical atomic clocks based on confinement in an optical lattice.

physics.atom-ph