Searcharxiv⌕ Search

arXiv subjects

T. Ma

Publications and source records attributed to T. Ma.

26 records · Page 2Linked to original sources

Broadband, electrically tuneable, third harmonic generation in graphene

Optical harmonic generation occurs when high intensity light ($>10^{10}$W/m$^{2}$) interacts with a nonlinear material. Electrical control of the nonlinear optical response enables applications such as gate-tunable switches and frequency converters. Graphene displays exceptionally strong-light matter interaction and electrically and broadband tunable third order nonlinear susceptibility. Here we show that the third harmonic generation efficiency in graphene can be tuned by over two orders of magnitude by controlling the Fermi energy and the incident photon energy. This is due to logarithmic resonances in the imaginary part of the nonlinear conductivity arising from multi-photon transitions. Thanks to the linear dispersion of the massless Dirac fermions, ultrabroadband electrical tunability can be achieved, paving the way to electrically-tuneable broadband frequency converters for applications in optical communications and signal processing.

cond-mat.mes-hall↗

The DArk Matter Particle Explorer mission

The DArk Matter Particle Explorer (DAMPE), one of the four scientific space science missions within the framework of the Strategic Pioneer Program on Space Science of the Chinese Academy of Sciences, is a general purpose high energy cosmic-ray and gamma-ray observatory, which was successfully launched on December 17th, 2015 from the Jiuquan Satellite Launch Center. The DAMPE scientific objectives include the study of galactic cosmic rays up to $\sim 10$ TeV and hundreds of TeV for electrons/gammas and nuclei respectively, and the search for dark matter signatures in their spectra. In this paper we illustrate the layout of the DAMPE instrument, and discuss the results of beam tests and calibrations performed on ground. Finally we present the expected performance in space and give an overview of the mission key scientific goals.

astro-ph.IM↗

The first cryogenic DT layered, beryllium capsule implosion at the National Ignition Facility

NIF experiments with Be capsules have followed a path of the highly successful "high-foot" CH capsules. Several keyhole and ConA targets preceeded a DT layered shot. In addition to backscatter subtraction, laser drive multipliers were needed to match observed X-ray drives. Those for the picket (0.95), trough (1.0) and second pulse (0.80) were determined by VISAR measurements. The time dependence of the Dante total x-ray flux and its fraction > 1.8 keV reflect the time dependence of the multipliers. A two step drive multiplier for the main pulse can match implosion times, but Dante measurements suggest the drive multiplier must increase late in time. With a single set of time dependent, multi-level multipliers the Dante data are well matched. These same third pulse drive multipliers also match the implosion times and Dante signals for two CH capsule DT. One discrepancy in the calculations is the X-ray flux in the picket. Calculations over-estimate the flux > 1.8 keV by a factor of ~100, while getting the total flux correctly. These harder X-rays cause an expansion of the Be/fuel interface of 2-3 km/s before the arrival of the first shock. VISAR measurements show only 0.2 to 0.3 km/s. The X-ray drive on the DT Be capsule was further degraded by a random decrease of 9% in the total picket flux. This small change caused the capsule fuel to change from an adiabat of 1.8 to 2.3 by mistiming of the first and second shocks. With this shock tuning and adjustments to the calculation, the first NIF Be capsule implosion achieved 29% of calculated yield, comparable to the CH DT capsules of 68% and 21%. Inclusion of a large M1 asymmetry in the DT ice layer and mixing from instability growth may help explain this final degradation. In summary when driven similarly the Be capsules performed like CH capsules. Performance degradation for both seems to be dominated by drive and capsule asymmetries.

physics.plasm-ph↗

Rejuvenation of metallic glasses under high pressure

Modulating energy states of metallic glasses (MGs) is significant in understanding the nature of glasses and control their properties. In this study, we show that rejuvenation in enthalpy can be achieved and preserved in bulk MGs by using high pressure (HP) annealing, which is a controllable method to continuously alter the energy states of MGs. Contrary to the decrease in enthalpy by conventional annealing at ambient pressure, such rejuvenation can occur and be enhanced by increasing both of annealing temperature and pressure. By using double aberration corrected scanning transmission electron microscopy, it is revealed that the rejuvenation, which is attributed to coupling effect of high pressure and high temperature, originates from the microstructural change that involves "negative flow units" with a higher atomic packing density compared to that of the elastic matrix of MGs. The results demonstrate that HP annealing is an effective way to rejuvenate MGs into higher energy states, and it may assist in understanding the microstructural origin of the rejuvenation in MGs.

cond-mat.mtrl-sci↗

Precise determination of $^{12}_Λ$C level structure by $γ$-ray spectroscopy

Level structure of the $^{12}_Λ$C hypernucleus was precisely determined by means of $γ$-ray spectroscopy. We identified four $γ$-ray transitions via the $^{12}$C$(π^{+},K^{+}γ)$ reaction using a germanium detector array, Hyperball2. The spacing of the ground-state doublet $(2^{-}_{1},1^{-}_{1})$ was measured to be $161.5\pm0.3\text{(stat)}\pm0.3\text{(syst)}$\,keV from the direct $M1$ transition. Excitation energies of the $1^{-}_{2}$ and $1^{-}_{3}$ states were measured to be $2832\pm3\pm4$\,keV and $6050\pm8\pm7$\,keV, respectively. The obtained level energies provide definitive references for the reaction spectroscopy of $Λ$ hypernuclei.

nucl-ex↗

The TITAN in-trap decay spectroscopy facility at TRIUMF

This article presents an upgraded in-trap decay spectroscopy apparatus which has been developed and constructed for use with TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). This device consists of an open-access electron-beam ion-trap (EBIT), which is surrounded radially by seven low-energy planar Si(Li) detectors. The environment of the EBIT allows for the detection of low-energy photons by providing backing-free storage of the radioactive ions, while guiding charged decay particles away from the trap centre via the strong (up to 6 T) magnetic field. In addition to excellent ion confinement and storage, the EBIT also provides a venue for performing decay spectroscopy on highly-charged radioactive ions. Recent technical advancements have been able to provide a significant increase in sensitivity for low-energy photon detection, towards the goal of measuring weak electron-capture branching ratios of the intermediate nuclei in the two-neutrino double beta ($2νββ$) decay process. The design, development, and commissioning of this apparatus are presented together with the main physics objectives. The future of the device and experimental technique are discussed.

physics.ins-det↗

Higgs Working Group Report of the Snowmass 2013 Community Planning Study

This report summarizes the work of the Energy Frontier Higgs Boson working group of the 2013 Community Summer Study (Snowmass). We identify the key elements of a precision Higgs physics program and document the physics potential of future experimental facilities as elucidated during the Snowmass study. We study Higgs couplings to gauge boson and fermion pairs, double Higgs production for the Higgs self-coupling, its quantum numbers and $CP$-mixing in Higgs couplings, the Higgs mass and total width, and prospects for direct searches for additional Higgs bosons in extensions of the Standard Model. Our report includes projections of measurement capabilities from detailed studies of the Compact Linear Collider (CLIC), a Gamma-Gamma Collider, the International Linear Collider (ILC), the Large Hadron Collider High-Luminosity Upgrade (HL-LHC), Very Large Hadron Colliders up to 100 TeV (VLHC), a Muon Collider, and a Triple-Large Electron Positron Collider (TLEP).

hep-ex↗

Observation of inhibited electron-ion coupling in strongly heated graphite

Creating non-equilibrium states of matter with highly unequal electron and lattice temperatures allows unsurpassed insight into the dynamic coupling between electrons and ions through time-resolved energy relaxation measurements. Recent studies on low-temperature laser-heated graphite suggest a complex energy exchange when compared to other materials. To avoid problems related to surface preparation, crystal quality and poor understanding of the energy deposition and transport mechanisms, we apply a different energy deposition mechanism, via laser-accelerated protons, to isochorically and non-radiatively heat macroscopic graphite samples up to temperatures close to the melting threshold. Using time-resolved x ray diffraction, we show clear evidence of a very small electron-ion energy transfer, yielding approximately three times longer relaxation times than previously reported. This is indicative of the existence of an energy transfer bottleneck in non-equilibrium warm dense matter.

physics.plasm-ph↗