SearcharxivSearch

arXiv subjects

T. Maeda

Publications and source records attributed to T. Maeda.

5 recordsLinked to original sources

FerroHEMTs: High-Current and High-Speed All-Epitaxial AlScN/GaN Ferroelectric Transistors

We report the first observation of ferroelectric gating in AlScN barrier wide-bandgap nitride transistors. These FerroHEMT devices realized by direct epitaxial growth represent a new class of ferroelectric transistors in which the semiconductor is itself polar, and the crystalline ferroelectric barrier is lattice-matched to the substrate. The FerroHEMTs reported here use the thinnest nitride high K and ferroelectric barriers to date to deliver the highest on currents at 4 A/mm, and highest speed AlScN transistors with fmax larger than 150 GHz observed in any ferroelectric transistor. The FerroHEMTs exhibit hysteretic Id Vgs loops with subthreshold slopes below the Boltzmann limit. A control AlN barrier HEMT exhibits neither hysteretic, nor sub Boltzmann behavior. While these results introduce the first epitaxial high K and ferroelectric barrier technology to RF and mm wave electronics, they are also of interest as a new material platform for combining memory and logic functionalities in digital electronics.

physics.app-ph

A study on energy resolution of CANDLES detector

In a neutrinoless double-beta decay ($0\nu\beta\beta$) experiment, energy resolution is important to distinguish between $0\nu\beta\beta$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0\nu\beta\beta$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value of $^{48}$Ca, the current energy resolution (2.6%) exceeds the ideal statistical fluctuation of the number of photoelectrons (1.6%). Because of CaF$_2$'s long decay constant of 1000 ns, a signal integration within 4000 ns is used to calculate the energy. The baseline fluctuation ($\sigma_{baseline}$) is accumulated in the signal integration, thus degrading the energy resolution. This paper studies $\sigma_{baseline}$ in the CANDLES detector, which severely degrades the resolution by 1% at the Q-value of $^{48}$Ca. To avoid $\sigma_{\rm baseline}$, photon counting can be used to obtain the number of photoelectrons in each PMT; however, a significant photoelectron signal overlapping probability in each PMT causes missing photoelectrons in counting and reduces the energy resolution. "Partial photon counting" reduces $\sigma_{baseline}$ and minimizes photoelectron loss. We obtain improved energy resolutions of 4.5-4.0% at 1460.8 keV ($\gamma$-ray of $^{40}$K), and 3.3-2.9% at 2614.5 keV ($\gamma$-ray of $^{208}$Tl). The energy resolution at the Q-value is estimated to be improved from 2.6% to 2.2%, and the detector sensitivity for the $0\nu\beta\beta$ half-life of $^{48}$Ca can be improved by 1.09 times.

physics.ins-det

Low background measurement in CANDLES-III for studying the neutrino-less double beta decay of $^{48}$Ca

We developed a CANDLES-III system to study the neutrino-less double beta (0$\nu\beta\beta$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$\pi$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal backgrounds caused by the radioactive impurities within the CaF$_2$ crystals can be reduced effectively through analysis of the signal pulse shape. We analyzed the data obtained in the Kamioka underground for a live-time of 130.4\,days to evaluate the feasibility of the low background measurement with the CANDLES-III detector. Using Monte Carlo simulations, we estimated the background rate from the radioactive impurities in the CaF$_{2}$ crystals and the rate of high energy $\gamma$-rays caused by the (n, $\gamma$) reactions induced by environmental neutrons. The expected background rate was in a good agreement with the measured rate, i.e., approximately 10$^{-3}$ events/keV/yr/(kg of $^{\rm nat.}$Ca), in the 0$\nu\beta\beta$ window. In conclusion, the background candidates were estimated properly by comparing the measured energy spectrum with the background simulations. With this measurement method, we performed the first search for 0$\nu\beta\beta$ decay in a low background condition using a detector with a Ca isotope, in which the Ca present was not enriched, in a scale of hundreds of kg. The $^{48}$Ca isotope has a high potential for use in 0$\nu\beta\beta$ decay search, and is expected to be useful for the development of a next-generation detector for highly sensitive measurements.

hep-ex

The energy calibration system for CANDLES using (n, \gamma) reaction

CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of a standard high-energy $\gamma$-ray source. Therefore, we have developed a novel calibration system based on $\gamma$-ray emission by neutron capture on $^{28}$Si, $^{56}$Fe and $^{58}$Ni nuclei. In the paper, we report the development of the new calibration system as well as the results of energy calibration in CANDLES up to 9 MeV.

physics.ins-det

$\mu$TCA DAQ system and parallel reading in CANDLES experiment

A new $\mu$TCA DAQ system was introduced in CANDLES experiment with SpaceWire-to-GigabitEthernet (SpaceWire-GigabitEthernet) network for data readout and Flash Analog-to-Digital Converters (FADCs). With SpaceWire-GigabitEthernet, we can construct a flexible DAQ network with multi-path access to FADCs by using off-the-shelf computers. FADCs are equipped 8 event buffers, which act as de-randomizer to detect sequential decays from the background. SpaceWire-GigabitEthernet has high latency (about 100 $\mu$sec) due to long turnaround time, while GigabitEthernet has high throughput. To reduce dead-time, we developed the DAQ system with 4 "crate-parallel" (modules in crates are read in parallel) reading threads. As a result, the readout time is reduced by 4 times: 40 msec down to 10 msec. With improved performance, it is expected to achieve higher background suppression for CANDLES experiment. Moreover, for energy calibration, "event-parallel" reading process (events are read in parallel) is also introduced to reduce measurement time. With 2 "event-parallel" reading processes, the data rate is increased 2 times.

physics.ins-det