Searcharxiv⌕ Search

arXiv subjects

T. Marrodan Undagoitia

Publications and source records attributed to T. Marrodan Undagoitia.

28 records · Page 2Linked to original sources

Gator: a low-background counting facility at the Gran Sasso Underground Laboratory

A low-background germanium spectrometer has been installed and is being operated in an ultra-low background shield (the Gator facility) at the Gran Sasso underground laboratory in Italy (LNGS). With an integrated rate of ~0.16 events/min in the energy range between 100-2700 keV, the background is comparable to those of the world's most sensitive germanium detectors. After a detailed description of the facility, its background sources as well as the calibration and efficiency measurements are introduced. Two independent analysis methods are described and compared using examples from selected sample measurements. The Gator facility is used to screen materials for XENON, GERDA, and in the context of next-generation astroparticle physics facilities such as DARWIN.

astro-ph.IM↗

Dark Matter Results from 100 Live Days of XENON100 Data

We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows to select only the innermost 48 kg as ultra-low background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in a pre-defined signal region with an expected background of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter interactions today, excluding spin-independent elastic WIMP-nucleon scattering cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90% confidence level.

astro-ph.CO↗

Material screening and selection for XENON100

Results of the extensive radioactivity screening campaign to identify materials for the construction of XENON100 are reported. This Dark Matter search experiment is operated underground at Laboratori Nazionali del Gran Sasso (LNGS), Italy. Several ultra sensitive High Purity Germanium detectors (HPGe) have been used for gamma ray spectrometry. Mass spectrometry has been applied for a few low mass plastic samples. Detailed tables with the radioactive contaminations of all screened samples are presented, together with the implications for XENON100.

physics.ins-det↗

Spatially uniform calibration of a liquid xenon detector at low energies using 83m-Kr

A difficult task with many particle detectors focusing on interactions below ~100 keV is to perform a calibration in the appropriate energy range that adequately probes all regions of the detector. Because detector response can vary greatly in various locations within the device, a spatially uniform calibration is important. We present a new method for calibration of liquid xenon (LXe) detectors, using the short-lived 83m-Kr. This source has transitions at 9.4 and 32.1 keV, and as a noble gas like Xe, it disperses uniformly in all regions of the detector. Even for low source activities, the existence of the two transitions provides a method of identifying the decays that is free of background. We find that at decreasing energies, the LXe light yield increases, while the amount of electric field quenching is diminished. Additionally, we show that if any long-lived radioactive backgrounds are introduced by this method, they will present less than 67E-6 events/kg/day in the next generation of LXe dark matter direct detection searches

astro-ph.IM↗

Spectroscopy of electron-induced fluorescence in organic liquid scintillators

Emission spectra of several organic liquid-scintillator mixtures which are relevant for the proposed LENA detector have been measured by exciting the medium with electrons of ~10keV. The results are compared with spectra resulting from ultraviolet light excitation. Good agreement between spectra measured by both methods has been found.

physics.ins-det↗

Fluorescence decay-time constants in organic liquid scintillators

The fluorescence decay-time constants have been measured for several scintillator mixtures based on phenyl-o-xylylethane (PXE) and linear alkylbenzene (LAB) solvents. The resulting values are of relevance for the physics performance of the proposed large-volume liquid scintillator detector LENA (Low Energy Neutrino Astronomy). In particular, the impact of the measured values to the search for proton decay via p -> K+ antineutrino is evaluated in this work.

physics.ins-det↗

Large underground, liquid based detectors for astro-particle physics in Europe: scientific case and prospects

This document reports on a series of experimental and theoretical studies conducted to assess the astro-particle physics potential of three future large-scale particle detectors proposed in Europe as next generation underground observatories. The proposed apparatus employ three different and, to some extent, complementary detection techniques: GLACIER (liquid Argon TPC), LENA (liquid scintillator) and MEMPHYS (\WC), based on the use of large mass of liquids as active detection media. The results of these studies are presented along with a critical discussion of the performance attainable by the three proposed approaches coupled to existing or planned underground laboratories, in relation to open and outstanding physics issues such as the search for matter instability, the detection of astrophysical- and geo-neutrinos and to the possible use of these detectors in future high-intensity neutrino beams.

hep-ph↗

Detection potential for the diffuse supernova neutrino background in the large liquid-scintillator detector LENA

The large-volume liquid-scintillator detector LENA (Low Energy Neutrino Astronomy) will provide high-grade background discrimination and enable the detection of diffuse supernova neutrinos (DSN) in an almost background-free energy window from ~10 to 25 MeV. Within ten years of exposure, it will be possible to derive significant constraints on both core-collapse supernova models and the supernova rate in the near universe up to redshifts z<2.

astro-ph↗

Low energy neutrino astronomy with the large liquid scintillation detector LENA

The detection of low energy neutrinos in a large scintillation detector may provide further important information on astrophysical processes as supernova physics, solar physics and elementary particle physics as well as geophysics. In this contribution, a new project for Low Energy Neutrino Astronomy (LENA) consisting of a 50kt scintillation detector is presented.

hep-ph↗

Search for the proton decay p->K+antineutrino in the large liquid scintillator low energy neutrino astronomy detector LENA

The LENA (Low Energy Neutrino Astronomy) detector is proposed to be a large-volume liquid-scintillator device which will be highly suitable for the investigation of a variety of topics in astrophysics, geophysics and particle physics. In this paper, the potential of such a detector concerning the search for proton decay in the SUSY favored decay channel p->K+antineutrino is investigated. Based on Geant4, Monte Carlo simulations of the proton decay in the LENA detector as well as of the background radiation in the detection energy windows have been developed. From these simulations an efficiency of 65% for the detection of a possible proton decay has been determined. Within ten years of measuring time a lower limit for the proton lifetime, concerning the decay channel investigated, of tau>4.10^{34} y could be reached.

hep-ph↗