Searcharxiv⌕ Search

arXiv subjects

T. Nakadaira

Publications and source records attributed to T. Nakadaira.

82 records · Page 5Linked to original sources

Study of Non-Standard Neutrino Interactions with Atmospheric Neutrino Data in Super-Kamiokande I and II

In this paper we study non-standard neutrino interactions as an example of physics beyond the standard model using atmospheric neutrino data collected during the Super-Kamiokande I(1996-2001) and II(2003-2005) periods. We focus on flavor-changing-neutral-currents (FCNC), which allow neutrino flavor transitions via neutral current interactions, and effects which violate lepton non-universality (NU) and give rise to different neutral-current interaction-amplitudes for different neutrino flavors. We obtain a limit on the FCNC coupling parameter, varepsilon_{mu tau}, |varepsilon_{mu tau}|<1.1 x 10^{-2} at 90%C.L. and various constraints on other FCNC parameters as a function of the NU coupling, varepsilon_{e e}. We find no evidence of non-standard neutrino interactions in the Super-Kamiokande atmospheric data.

hep-ex↗

Measurements of Cross Sections and Charged Pion Spectra in Proton-Carbon Interactions at 31 GeV/c

Interaction cross sections and charged pion spectra in p+C interactions at 31 GeV/c were measured with the large acceptance NA61/SHINE spectrometer at the CERN SPS. These data are required to improve predictions of the neutrino flux for the T2K long baseline neutrino oscillation experiment in Japan. A set of data collected during the first NA61/SHINE run in 2007 with an isotropic graphite target with a thickness of 4% of a nuclear interaction length was used for the analysis. The measured p+C inelastic and production cross sections are 257.2 +- 1.9 +- 8.9 mb and 229.3 +- 1.9 +- 9.0 mb, respectively. Inclusive production cross sections for negatively and positively charged pions are presented as a function of laboratory momentum in 10 intervals of the laboratory polar angle covering the range from 0 up to 420 mrad. The spectra are compared with predictions of several hadron production models.

hep-ex↗

Performance of Multi-Pixel Photon Counters for the T2K near detectors

We have developed a Multi-Pixel Photon Counter (MPPC) for the neutrino detectors of T2K experiment. About 64,000 MPPCs have been produced and tested in about a year. In order to characterize a large number of MPPCs, we have developed a system that simultaneously measures 64 MPPCs with various bias voltage and temperature. The performance of MPPCs are found to satisfy the requirement of T2K experiment. In this paper, we present the performance of 17,686 MPPCs measured at Kyoto University.

physics.ins-det↗

Atmospheric neutrino oscillation analysis with sub-leading effects in Super-Kamiokande I, II, and III

We present a search for non-zero theta_{13} and deviations of sin^2 theta_{23} from 0.5 in the oscillations of atmospheric neutrino data from Super-Kamiokande -I, -II, and -III. No distortions of the neutrino flux consistent with non-zero theta_{13} are found and both neutrino mass hierarchy hypotheses are in agreement with the data. The data are best fit at Delta m^2 = 2.1 x 10^-3 eV^2, sin^2 theta_{13} = 0.0, and sin^2 theta_{23} =0.5. In the normal (inverted) hierarchy theta_{13} and Delta m^2 are constrained at the one-dimensional 90% C.L. to sin^2 theta_{13} < 0.04 (0.09) and 1.9 (1.7) x 10^-3 < Delta m^2 < 2.6 (2.7) x 10^-3 eV^2. The atmospheric mixing angle is within 0.407 <= sin^2 theta_{23} <= 0.583 at 90% C.L.

hep-ex↗

Application of Hamamatsu MPPC to T2K Neutrino Detectors

A special type of Hamamatsu MPPC, with a sensitive area of 1.3x1.3mm^2 containing 667 pixels with 50x50um^2 each, has been developed for the near neutrino detector in the T2K long baseline neutrino experiment. About 60 000 MPPCs will be used in total to read out the plastic scintillator detectors with wavelength shifting fibers. We report on the basic performance of MPPCs produced for T2K.

physics.ins-det↗

Mass production test of Hamamatsu MPPC for T2K neutrino oscillation experiment

In the T2K near neutrino detectors, about 60 000 Hamamatsu Multi-Pixel Photon Counters (MPPCs) will be used. The mass production of MPPC has started in February 2008.In order to perform quality assurance and to characterize each device, we have developed an MPPC test system. For each MPPC, gain, breakdown voltage, noise rate, photo detection efficiency, and cross-talk and after-pulse rate are measured as functions of the bias voltage and temperature. The design of the test system and the measurement procedure are described.

physics.ins-det↗

Detectors and flux instrumentation for future neutrino facilities

This report summarises the conclusions from the detector group of the International Scoping Study of a future Neutrino Factory and Super-Beam neutrino facility. The baseline detector options for each possible neutrino beam are defined as follows: 1. A very massive (Megaton) water Cherenkov detector is the baseline option for a sub-GeV Beta Beam and Super Beam facility. 2. There are a number of possibilities for either a Beta Beam or Super Beam (SB) medium energy facility between 1-5 GeV. These include a totally active scintillating detector (TASD), a liquid argon TPC or a water Cherenkov detector. 3. A 100 kton magnetized iron neutrino detector (MIND) is the baseline to detect the wrong sign muon final states (golden channel) at a high energy (20-50 GeV) neutrino factory from muon decay. A 10 kton hybrid neutrino magnetic emulsion cloud chamber detector for wrong sign tau detection (silver channel) is a possible complement to MIND, if one needs to resolve degeneracies that appear in the $δ$-$θ_{13}$ parameter space.

physics.ins-det↗

Development of Multi-Pixel Photon Counters

The multi-pixel photon counter (MPPC) is a newly developed photodetector with an excellent photon counting capability. It also has many attractive features such as small size, high gain, low operation voltage and power consumption, and capability of operating in magnetic fields and in room temperature. The basic performance of samples has been measured. A gain of ~10^6 is achieved with a noise rate less than 1 MHz with 1 p.e. threshold, and cross-talk probability of less than 30% at room temperature. The photon detection efficiency for green light is twice or more that of the photomultiplier tubes. It is found that the basic performance of the MPPC is satisfactory for use in real experiments.

physics.ins-det↗

CP violation in B0 -> pi+ pi- decay

We present an improved measurement of CP-violating asymmetries in B0 -> pi+ pi- decays based on a 78/fb data sample collected at the Y(4S) resonance with the Belle detector at the KEKB asymmetric-energy e+e- collider. We reconstruct one neutral B meson as a B0 -> pi+ pi- CP eigenstate and identify the flavor of the accompanying B meson from its decay products. From the asymmetry in the distribution of the time intervals between the two B meson decay points, we obtain the CP-violating asymmetry amplitudes Apipi = +0.77+/-0.27(stat)+/-0.08(syst) and Spipi = -1.23+/-0.41(stat)+0.08/-0.07(syst), where the statistical uncertainties are determined from Monte Carlo pseudo-experiments. We rule out the CP-conserving case, Apipi=Spipi=0, at the 99.93% confidence level. We discuss how these results constrain the value of the CKM angle phi2.

hep-ex↗