SearcharxivSearch

arXiv subjects

T. Nania

Publications and source records attributed to T. Nania.

6 recordsLinked to original sources

Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers

The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by a hot-spike as previously supposed. Using this semi-empirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c$^{-2}$.

physics.ins-det

Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber

Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$ cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.

astro-ph.CO

Developing a Bubble Chamber Particle Discriminator Using Semi-Supervised Learning

The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually developing a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing formats and neural network architectures are applied to the task. First, they are optimized in a supervised learning context. Next, two novel semi-supervised learning algorithms are trained, and found to replicate the Acoustic Parameter (AP) discriminator previously used in PICO-60 with a mean of 97% accuracy.

physics.comp-ph

Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber

New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than 1 event per month. A blind analysis of an efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 3.4 $\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one order of magnitude improvement from previous PICO results.

astro-ph.CO

Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I Bubble Chamber

We have directly measured the energy threshold and efficiency for bubble nucleation from iodine recoils in a CF3I bubble chamber in the energy range of interest for a dark matter search. These interactions cannot be probed by standard neutron calibration methods, so we develop a new technique by observing the elastic scattering of 12 GeV/c negative pions. The pions are tracked with a silicon pixel telescope and the reconstructed scattering angle provides a measure of the nuclear recoil kinetic energy. The bubble chamber was operated with a nominal threshold of (13.6+-0.6) keV. Interpretation of the results depends on the response to fluorine and carbon recoils, but in general we find agreement with the predictions of the classical bubble nucleation theory. This measurement confirms the applicability of CF3I as a target for spin-independent dark matter interactions and represents a novel technique for calibration of superheated fluid detectors.

physics.ins-det

First dark matter search results from a 4-kg CF$_3$I bubble chamber operated in a deep underground site

New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha-decay background events from single nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of alpha-decay events. Twenty single nuclear recoil event candidates and three multiple bubble events were observed during a total exposure of 553 kg-days distributed over three different bubble nucleation thresholds. The effective exposure for single bubble recoil-like events was 437.4 kg-days. A neutron background internal to the apparatus, of known origin, is estimated to account for five single nuclear recoil events and is consistent with the observed rate of multiple bubble events. This observation provides world best direct detection constraints on WIMP-proton spin-dependent scattering for WIMP masses $>$20 GeV/c$^{2}$ and demonstrates significant sensitivity for spin-independent interactions.

astro-ph.CO