SearcharxivSearch

arXiv subjects

T. Narita

Publications and source records attributed to T. Narita.

At least 19 recordsLinked to original sources

Effects of lightning strokes on underground gravitational waves observatories

For ground-based gravitational wave (GW) detectors, lightning strokes in the atmosphere are sources of environmental noise. Some GW detectors are built or planned in underground facilities, and knowledge of how lightning strokes affect them is of interest. In this paper, the lightning detection system in KAGRA is introduced, and the properties of the magnetic field measured inside and outside the KAGRA tunnel are shown. One lightning-induced event in the GW channel of the KAGRA main interferometer is also shown. Finally, possible applications of lightning events for the GW experiments are discussed.

gr-qc

GRAPE - A Balloon-Borne Gamma-Ray Polarimeter Experiment

This paper reviews the development status of GRAPE (the Gamma-Ray Polarimeter Experiment), a hard X-ray Compton Polarimeter. The purpose of GRAPE is to measure the polarization of hard X-rays in the 50-300 keV energy range. We are particularly interested in X-rays that are emitted from solar flares and gamma-ray bursts (GRBs), although GRAPE could also be employed in the study of other astrophysical sources. Accurately measuring the polarization of the emitted radiation will lead to a better understating of both emission mechanisms and source geometries. The GRAPE design consists of an array of plastic scintillators surrounding a central high-Z crystal scintillator. The azimuthal distribution of photon scatters from the plastic array into the central calorimeter provides a measure of the polarization fraction and polarization angle of the incident radiation. The design of the detector provides sensitivity over a large field-of-view (>pi steradian). The design facilitates the fabrication of large area arrays with minimal deadspace. This paper presents the latest design concept and the most recent results from laboratory tests of a GRAPE science model.

astro-ph

Developing a Compton Polarimeter to Measure Polarization of Hard X-Rays in the 50-300 keV Energy Range

This paper discusses the latest progress in the development of GRAPE (Gamma-Ray Polarimeter Experiment), a hard X-ray Compton Polarimeter. The purpose of GRAPE is to measure the polarization of hard X-rays in the 50-300 keV energy range. We are particularly interested in X-rays that are emitted from solar flares and gamma-ray bursts (GRBs). Accurately measuring the polarization of the emitted radiation from these sources will lead, to a better understating of both the emission mechanisms and source geometries. The GRAPE design consists of an array of plastic scintillators surrounding a central high-Z crystal scintillator. We can monitor individual Compton scatters that occur in the plastics and determine whether the photon is photo absorbed by the high-Z crystal or not. A Compton scattered photon that is immediately photo absorbed by the high-Z crystal constitutes a valid event. These valid events provide us with the interaction locations of each incident photon and ultimately produces a modulation pattern for the Compton scattering of the polarized radiation. Comparing with Monte Carlo simulations of a 100% polarized beam, the level of polarization of the measured beam can then be determined. The complete array is mounted on a flat-panel multi-anode photomultiplier tube (MAPMT) that can measure the deposited energies resulting from the photon interactions. The design of the detector allows for a large field-of-view (>pi steradian), at the same time offering the ability to be close-packed with multiple modules in order to reduce deadspace. We plan to present in this paper the latest laboratory results obtained from GRAPE using partially polarized radiation sources.

astro-ph

Multipixel characterization of imaging CZT detectors for hard X-ray imaging and spectroscopy

We report our in-depth study of Cd-Zn-Te (CZT) crystals to determine an optimum pixel and guard band configuration for Hard X-ray imaging and spectroscopy. We tested 20x20x5mm crystals with 8x8 pixels on a 2.46mm pitch. We have studied different types of cathode / anode contacts and different pixel pad sizes. We present the measurements of leakage current as well as spectral response for each pixel. Our I-V measurement setup is custom designed to allow automated measurements of the I-V curves sequentially for all 64 pixels, whereas the radiation properties measurement setup allows for interchangeable crystals with the same XAIM3.2 ASIC readout from IDEAS. We have tested multiple crystals of each type, and each crystal in different positions to measure the variation between individual crystals and variation among the ASIC channels. We also compare the same crystals with and without a grounded guard band deposited on the crystal side walls vs. a floating guard band and compare results to simulations. This study was carried out to find the optimum CZT crystal configuration for prototype detectors for the proposed Black-Hole Finder mission, EXIST.

astro-ph

Laboratory coded aperture imaging experiments: radial hole coded masks and depth-sensitive CZT detectors

The proposed black-hole finder mission EXIST will consist of multiple wide-field hard X-ray coded-aperture telescopes. The high science goals set for the mission require innovations in telescope design. In particular, wide energy band coverage and fine angular resolution require relatively thick coded masks and thick detectors compared to their pixel size, which may introduce mask self-collimation and depth-induced image blurring with conventional design approaches. Previously we proposed relatively simple solutions to these potential problems: radial hole for mask selfcollimation and cathode depth sensing detector for image blurring. We have now performed laboratory experiments to explore the potential of these two techniques. The experimental results show that the radial hole mask greatly alleviates mask self-collimation and a ~1 mm resolution depth-sensitive detector scheme can be relatively easily achieved for the large scale required for EXIST.

astro-ph

EXITE2 Observation of the SIGMA Source GRS 1227+025

We report the EXITE2 hard X-ray imaging of the sky around 3C273. A 2h observation on May 8, 1997, shows a $\sim$260 mCrab source detected at $\sim4σ$ in each of two bands (50-70 and 70-93 keV) and located $\sim$30' from 3C273 and consistent in position with the SIGMA source GRS1227+025. The EXITE2 spectrum is consistent with a power law with photon index 3 and large low energy absorption, as indicated by the GRANAT/SIGMA results. No source was detected in more sensitive followup EXITE2 observations in 2000 and 2001 with 3$σ$ upper limits of 190 and 65 mCrab, respectively. Comparison with the flux detected by SIGMA shows the source to be highly variable, suggesting it may be non-thermal and beamed and thus the first example of a ``type 2'' (absorbed) Blazar. Alternatively it might be (an unprecedented) very highly absorbed binary system undergoing accretion disk instability outbursts, possibly either a magnetic CV, or a black hole X-ray nova.

astro-ph

Cathode depth sensing in CZT detectors

Measuring the depth of interaction in thick Cadmium-Zinc-Telluride (CZT) detectors allows improved imaging and spectroscopy for hard X-ray imaging above 100 keV. The Energetic X-ray Imaging Survey Telescope (EXIST) will employ relatively thick (5 - 10 mm) CZT detectors, which are required to perform the broad energy-band sky survey. Interaction depth information is needed to correct events to the detector "focal plane" for correct imaging and can be used to improve the energy resolution of the detector at high energies by allowing event-based corrections for incomplete charge collection. Background rejection is also improved by allowing low energy events from the rear and sides of the detector to be rejected. We present experimental results of interaction depth sensing in a 5 mm thick pixellated Au-contact IMARAD CZT detector. The depth sensing was done by making simultaneous measurements of cathode and anode signals, where the interaction depth at a given energy is proportional to the ratio of cathode/anode signals. We demonstrate how a simple empirical formula describing the event distributions in the cathode/anode signal space can dramatically improve the energy resolution. We also estimate the energy and depth resolution of the detector as a function of the energy and the interaction depth. We also show a depth-sensing prototype system currently under development for EXIST in which cathode signals from 8, 16 or 32 crystals can be read-out by a small multi-channel ASIC board that is vertically edge-mounted on the cathode electrode along every second CZT crystal boundary. This allows CZT crystals to be tiled contiguously with minimum impact on throughput of incoming photons. The robust packaging is crucial in EXIST, which will employ very large area imaging CZT detector arrays.

astro-ph

Partial rejuvenation of a colloidal glass

We study the effect of shear on the aging dynamics of a colloidal suspension of synthetic clay particles. We find that a shear of amplitude $γ$ reduces the relaxation time measured just after the cessation of shear by a factor $\exp(-γ/γ_c)$, with $γ_c \sim 5%$, and is independent of the duration and the frequency of the shear. This simple law for the rejuvenation effect shows that the energy involved in colloidal rearrangements is proportional to the shear amplitude, $γ$, rather than $γ^2$, leading to an Eyring-like description of the dynamics of our system.

cond-mat.soft

X-ray Dip Monitoring of XB 1916-053

We report on the long term monitoring of X-ray dips from the ultracompact low-mass X-ray binary (LMXB) XB 1916-053. Roughly one-month interval observations were carried out with the Rossi X-ray Timing Explorer (RXTE) during 1996, during which the source varied between dim, hard states and more luminous, soft states. The dip spectra and dip lightcurves were compared against both the broadband luminosity and the derived mass accretion rate Mdot. The dips spectra could be fitted by an absorbed blackbody plus cut-off power law non-dip spectral model, with additional absorption ranging from 0 to >100 x 10^22 cm^-2. The amount of additional blackbody absorption was found to vary with the source luminosity. Our results are consistent with an obscuration of the inner disk region by a partially ionized outer disk. The size of the corona, derived from the dip ingress times, was found to be ~10^9 cm. The corona size did not correlate with the coronal temperature, but seemed to increase when \Mdot also increased. We discuss our findings in the context of an evaporated accretion disk corona model and an ADAF-type model.

astro-ph

Balloon Flight Background Measurement with Actively-Shielded Planar and Imaging CZT Detectors

We present results from the flight of two prototype CZT detectors on a scientific balloon payload in September 2000. The first detector, referred to as ``CZT1,'' consisted of a 10 mm x 10 mm x 2 mm CZT crystal with a single gold planar electrode readout. This detector was shielded by a combination of a passive collimator surrounded by plastic scintillator and a thick BGO crystal in the rear. The second detector, ``CZT2,'' comprised two 10 mm x 10 mm x 5 mm CZT crystals, one made of eV Products high pressure Bridgman material and the other of IMARAD horizontal Bridgman material, each fashioned with a 4 x 4 array of gold pixels on a 2.5 mm pitch. The pixellated detectors were flip-chip-mounted side by side and read out by a 32-channel ASIC. This detector was also shielded by a passive/plastic collimator in the front, but used only additional passive/plastic shielding in the rear. Both experiments were flown from Ft. Sumner, NM on September 19, 2000 on a 24 hour balloon flight. CZT1 recorded a non-vetoed background level at 100 keV of ~1e-3 cts/cm2/s/keV. Raising the BGO threshold from 50 keV to ~1 MeV produced only an 18% increase in this level. CZT2 recorded a background at 100 keV of ~4e-3 cts/cm2/s/keV in the eV Products detector and ~6e-3 cts/cm2/s/keV in the IMARAD detector. Both CZT1 and CZT2 spectra were in basic agreement with Monte Carlo simulations, though both recorded systematically higher count rates at high energy than predicted. No lines were observed, indicating that neutron capture reactions, at least those producing decay lines at a few 100 keV, are not significant components of the CZT background. Comparison of the CZT1 and CZT2 spectra indicates that passive/plastic shielding may provide adequately low background levels for many applications.

astro-ph

Development of an XSPEC-Based Spectral Analysis System for the Coded-Aperture Hard X-ray Balloon Payload EXITE2

We present the spectral analysis system for the second-generation Energetic X-ray Imaging Telescope Experiment (EXITE2) balloon payload. EXITE2 is an imaging hard X-ray telescope using a coded-aperture mask and a NaI/CsI phoswich detector operating in the energy range 20--600 keV. The instrument was flown on a high-altitude scientific balloon from Ft. Sumner, NM on 1997 May 7-8. We describe the details of the EXITE2 spectral analysis system, with emphasis on those aspects peculiar to coded-aperture instruments. In particular, we have made our analysis compatible with the standard X-ray spectral fitting package XSPEC by generating a response matrix in the appropriate format including all the effects of a coded-aperture system. The use of XSPEC, which may be a first for coded-aperture data, permits great flexibility in the fitting of spectral models. The additional effects of our phoswich system, or any other detector-specific considerations, may be easily included as well. We test our spectral analysis using observations of the Crab Nebula, and find that the EXITE2 Crab spectrum is consistent with those recorded by previous instruments operating in this energy range.

astro-ph

Construction and Testing of a Pixellated CZT Detector and Shield for a Hard X-ray Astronomy Balloon Flight

We report on the construction and laboratory testing of pixellated CZT detectors mounted in a flip-chip, tiled fashion and read out by an ASIC, as required for proposed hard X-ray astronomy missions. Two 10 mm x 10 mm x 5 mm detectors were fabricated, one out of standard eV Products high-pressure Bridgman CZT and one out of IMARAD horizontal Bridgman CZT. Each was fashioned with a 4 x 4 array of gold pixels on a 2.5 mm pitch with a surrounding guard ring. The detectors were mounted side by side on a carrier card, such that the pixel pitch was preserved, and read out by a 32-channel VA-TA ASIC from IDE AS Corp. controlled by a PC/104 single-board computer. A passive shield/collimator surrounded by plastic scintillator encloses the detectors on five sides and provides a ~40deg field of view. Thus this experiment tests key techniques required for future hard X-ray survey instruments. The experiment was taken to Ft Sumner, NM in May 2000 in preparation for a scientific balloon flight aboard the joint Harvard-MSFC EXITE2/HERO payload. Although we did not receive a flight opportunity, and are currently scheduled to fly in September 2000, we present our calibration data in the flight configuration together with data analysis techniques and simulations of the expected flight background spectrum.

astro-ph

ASCA Observations of GX 354-0 and KS 1731-260

We report on ASCA observations of the low mass X-ray binaries GX 354-0 and KS 1731-260. The spectrum of GX 354-0 is best described as a power-law or a Comptonized spectrum with tau ~ 5 and kT ~ 8 keV and a residual at ~6.5 keV. The residual may be a disk reflection or a Compton broadened Gaussian line from the hot inner ADAF-like coronal region. The absorption column density to the source is 2.9e22 cm^-2. No soft thermal component was detected. The spectrum from KS 1731-260 is softer and it is best fit with a two component model with a column density of 1.1e22 cm^-2. The likely interpretation is emission from a Comptonizing cloud with an optical depth tau>12 and either a neutron star or a disk blackbody emission. We discuss the likely location of the Comptonizing cloud for both sources within the context of several proposed emission models.

astro-ph

Development of Gold Contacted Flip-chip Detectors with IMARAD CZT

We present initial results from our evaluation of a gold-contacted pixellated detector using cadmium zinc telluride substrate produced by IMARAD Imaging Systems. The Horizontal Bridgman (HB) grown crystals from IMARAD have been shown to produce high resolution photopeaks, but they are also seen to have large leakage current. Our previous tests with IMARAD CZT showed that the use of indium anodes and gold cathode improved the resistivity compared to the standard indium-contacted detectors. We seek to test whether simple evaporated gold contacts alone could also reduce the leakage current and thus improve the spectral resolution, especially in the 10-100 keV energy range. We have fabricated several metal-semiconductor-metal (MSM) detectors with a 4x4 array of pixels on 10x10 mm substrates. Measurements of the detectors' leakage current, spectral response, and temperature sensitivity are presented and compared to IMARAD's ohmic contact detector and gold contact MSM detectors made of High Pressure Bridgman (HPB) material. Finally, we show preliminary results from a tiled flip-chip pixellated detector made using the IMARAD detectors.

astro-ph

Design and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy

We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm x 10 mm x 5 mm CZT detectors, each with a 4 x 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mounted in a ``flip-chip'' fashion on a printed circuit board carrier card; the detectors will be placed 0.3 mm apart in a tiled configuration such that the pixel pitch is preserved across both crystals. One detector is eV Products high-pressure Bridgman CZT, and the other is IMARAD horizontal Bridgman material. Both detectors are read out by a 32-channel VA-TA ASIC controlled by a PC/104 single-board computer. A passive shield/collimator surrounded by plastic scintillator surrounds the detectors on five sides and provides a ~45 deg field of view. The background spectrum recorded by this instrument will be compared to that measured by a single-element CZT detector (10 mm x 10 mm x 2 mm high-pressure Bridgman material from eV Products) fitted with the same passive/plastic collimator but including an active BGO shield to the rear. This detector has been previously flown by us completely shielded by a passive cover. We describe preliminary laboratory results for the various systems, discuss initial background simulations, and describe our plans for balloon flight tests.

astro-ph

CdZnTe Background Measurement at Balloon Altitudes

We report results of an experiment conducted in May 1997 to measure CdZnTe background and background reduction schemes in space flight conditions similar to those of proposed hard X-ray astrophysics missions. A 1 cm^2 CdZnTe detector was placed adjacent to a thick BGO anticoincidence shield and flown piggybacked onto the EXITE2 scientific balloon payload. The planar shield was designed to veto background countsproduced by local gamma-ray production in passive material and neutron interactions in the detector. The CdZnTe and BGO were partially surrounded by a Pb-Sn-Cu shield to approximate the grammage of an X-ray collimator, although the field of view was still ~2 pi sr. At an altitude of 127000 feet we find a reduction in background by a factor of 6 at 100 keV. The non-vetoed background is 9 X 10^{-4} cts /cm^2-sec-keV at 100 keV, about a factor of 2 higher than that of the collimated (4.5 deg FWHM) EXITE2 phoswich detector. We compare our recorded spectrum with that expected from simulations using GEANT and find agreement within a factor of 2 between 30 and 300 keV. We also compare our results with those of previous experiments using passive lead and active NaI shields, and discuss possible active shielding schemes in future astronomy missions employing large arrays of CdZnTe detectors.

astro-ph

Development of Prototype Pixellated PIN CdZnTe Detectors

We report initial results from the design and evaluation of two pixellated PIN Cadmium Zinc Telluride detectors and an ASIC-based readout system. The prototype imaging PIN detectors consist of 4X4 1.5 mm square indium anode contacts with 0.2 mm spacing and a solid cathode plane on 10X10 mm CdZnTe substrates of thickness 2 mm and 5 mm. The detector readout system, based on low noise preamplifier ASICs, allows for parallel readout of all channels upon cathode trigger. This prototype is under development for use in future astrophysical hard X-ray imagers with 10-600 keV energy response. Measurements of the detector uniformity, spatial resolution, and spectral resolution will be discussed and compared with a similar pixellated MSM detector. Finally, a prototype design for a large imaging array is outlined.

astro-ph

Prototype Imaging Cd-Zn-Te Array Detector

We describe initial results of our program to develop and test Cd-Zn-Te (CZT) detectors with a pixellated array readout. Our primary interest is in the development of relatively thick CZT detectors for use in astrophysical coded aperture telescopes with response extending over the energy range $\sim 10-600$ keV. The coded aperture imaging configuration requires only relatively large area pixels (1-3 mm), whereas the desired high energy response requires detector thicknesses of at least 3-5 mm. We have developed a prototype detector employing a 10 x 10 x 5 mm CZT substrate and 4 x 4 pixel (1.5 mm each) readout with gold metal contacts for the pixels and continuous gold contact for the bias on the opposite detector face. This MSM contact configuration was fabricated by RMD and tested at Harvard for uniformity, efficiency and spatial as well as spectral resolution. We have developed an ASIC readout (IDE-VA-1) and analysis system and report results, including $\sim 4$% (FWHM) energy resolution at 60 keV. A prototype design for a full imaging detector array is discussed.

astro-ph