SearcharxivSearch

arXiv subjects

T. Patel

Publications and source records attributed to T. Patel.

11 recordsLinked to original sources

The MUSE Target Chamber Post Veto

The Muon Scattering Experiment (MUSE) was developed to address the proton radius puzzle through simultaneous electron-proton and muon-proton scattering using the Paul Scherrer Institute's PiM1 secondary beamline. MUSE uses a large-solid-angle, non-magnetic spectrometer to detect beam particles scattering from a liquid hydrogen cell contained within a vacuum chamber. Due to the large scattering windows, the structural integrity of the chamber is supported by posts located at small scattering angles. While out of the acceptance, particles in the tails of the beam distribution can strike these posts, causing a significant trigger background. We describe the design and performance of the Target Chamber Post Veto (TCPV) detector installed inside the vacuum chamber to remove these background events at the trigger level.

physics.ins-det

The MUSE Beamline Calorimeter

The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron-proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron-proton and muon-proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. In this article we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.

physics.ins-det

Blinding for precision scattering experiments: The MUSE approach as a case study

Human bias is capable of changing the analysis of measured data sufficiently to alter the results of an experiment. It is incumbent upon modern experiments, especially those investigating quantities considered contentious in the broader community, to blind their analysis in an effort to minimize bias. The choice of a blinding model is experiment specific, but should also aim to prevent accidental release of results before an analysis is finalized. In this paper, we discuss common threats to an unbiased analysis, as well as common quantities that can be blinded in different types of nuclear physics experiments. We use the Muon Scattering Experiment as an example, and detail the blinding scheme used therein.

physics.data-an

The Two-Photon Exchange Experiment at DESY

We propose a new measurement of the ratio of positron-proton to electron-proton elastic scattering at DESY. The purpose is to determine the contributions beyond single-photon exchange, which are essential for the Quantum Electrodynamic (QED) description of the most fundamental process in hadronic physics. By utilizing a 20 cm long liquid hydrogen target in conjunction with the extracted beam from the DESY synchrotron, we can achieve an average luminosity of $2.12\times10^{35}$ cm$^{-2}\cdot$s$^{-1}\cdot$sr$^{-1}$ ($\approx200$ times the luminosity achieved by OLYMPUS). The proposed TPEX experiment entails a commissioning run at 2 GeV, followed by measurements at 3 GeV, thereby providing new data up to $Q^2=4.6$ (GeV/$c$)$^2$ (twice the range of current measurements). We present and discuss the proposed experimental setup, run plan, and expectations.

nucl-ex

Instrumental uncertainties in radiative corrections for the MUSE experiment

The MUSE experiment at the Paul Scherrer Institute is measuring elastic lepton-proton scattering cross sections in a four-momentum transfer range from $Q^2$ of approximately 0.002 to 0.08 GeV$^2$ using positively and negatively charged electrons and muons. The extraction of the Born cross sections from the experimental data requires radiative corrections. Estimates of the instrumental uncertainties in those corrections have been made using the ESEPP event generator. The results depend in particular on the minimum lepton momentum that contributes to the experimental cross section and the fraction of events with hard initial-state radiation that is detected in the MUSE calorimeter and is excluded from the data. These results show that the angular-dependent instrumental uncertainties in radiative corrections to the electron cross section are better than 0.4 % and are negligible for the muon cross section.

hep-ex

Two-Photon EXchange -- TPEX

We propose a new measurement of the ratio of positron-proton to electron-proton, elastic scattering at DESY to determine the contributions beyond single-photon exchange, which are essential to the QED description of the most fundamental process in hadronic physics. A 20~cm long liquid hydrogen target together with the extracted beam from the DESY synchrotron would yield an average luminosity of $2.12\times10^{35}$~cm$^{-2}\cdot$s$^{-1}\cdot$sr$^{-1}$ ($\sim200$ times the luminosity achieved by OLYMPUS). A commissioning run at 2 GeV followed by measurements at 3 GeV would provide new data up to $Q^2=4.6$~(GeV/$c$)$^2$ (twice the range of current measurements). Lead tungstate calorimeters would be used to detect the scattered leptons at polar angles of $30^\circ$, $50^\circ$, $70^\circ$, $90^\circ$, and $110^\circ$. The measurements could be scheduled to not interfere with the operation of PETRA. We present rate estimates and simulations for the planned measurements including background considerations. Initial measurements at the DESY test beam facility using prototype lead tungstate calorimeters in 2019, 2021, and 2022 were made to check the Monte Carlo simulations and the performance of the calorimeters. These tests also investigated different readout schemes (triggered and streaming). Various upgrades are possible to shorten the running time and to make higher beam energies and thus greater $Q^2$ ranges accessible.

nucl-ex

Searching for New Physics with DarkLight at the ARIEL Electron-Linac

The search for a dark photon holds considerable interest in the physics community. Such a force carrier would begin to illuminate the dark sector. Many experiments have searched for such a particle, but so far it has proven elusive. In recent years the concept of a low mass dark photon has gained popularity in the physics community. Of particular recent interest is the $^8$Be and $^4$He anomaly, which could be explained by a new fifth force carrier with a mass of 17 MeV/$c^2$. The proposed DarkLight experiment would search for this potential low mass force carrier at ARIEL in the 10-20 MeV e$^+$e$^-$ invariant mass range. This proceeding will focus on the experimental design and physics case of the DarkLight experiment.

nucl-ex

Characterization of plastic scintillator bars using fast neutrons from D-D and D-T reactions

We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse beta decay (IBD) signal. ISMRAN detector, an above-ground experiment close to the reactor core (~13m), deals with an active fast neutron background inside the reactor hall. A good understanding of fast neutron response in PS bars is an essential pre-requisite for suppression and discrimination of fast neutron background from IBD events. A monoenergetic neutron beam from the fusion reaction of D-D at 2.45 MeV and D-T at 14.1 MeV are used to characterize the energy response in these bars. The neutron energy response function has been simulated using the GEANT4 package and are compared with the measured data. A reasonable agreement of deposited energies by fast neutrons in PS bars between data and simulation are obtained for these reactions. The ratio of energy deposition in adjacent bars is used to discriminate between prompt IBD, fast neutron and neutron capture cascade gamma events.

physics.ins-det

Characterization of Muon and Electron Beams in the Paul Scherrer Institute PiM1 Channel for the MUSE Experiment

The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the properties of the beam line established for pions. We discuss the production processes that generate the electron and muon beams, and the simulations of these processes. Simulations of the $\pi$/$\mu$/$e$ beams through the channel using TURTLE and G4beamline are compared. The G4beamline simulation is then compared to several experimental measurements of the channel, including the momentum dispersion at the IFP and target, the shape of the beam spot at the target, and timing measurements that allow the beam momenta to be determined. We conclude that the PiM1 channel can be used for high precision $\pi$, $\mu$, and $e$ scattering.

physics.ins-det

Physics with Positron Beams at Jefferson Lab 12 GeV

Positron beams, both polarized and unpolarized, are identified as essential ingredients for the experimental program at the next generation of lepton accelerators. In the context of the Hadronic Physics program at the Jefferson Laboratory (JLab), positron beams are complementary, even essential, tools for a precise understanding of the electromagnetic structure of the nucleon, in both the elastic and the deep-inelastic regimes. For instance, elastic scattering of (un)polarized electrons and positrons off the nucleon allows for a model independent determination of the electromagnetic form factors of the nucleon. Also, the deeply virtual Compton scattering of (un)polarized electrons and positrons allows us to separate unambiguously the different contributions to the cross section of the lepto-production of photons, enabling an accurate determination of the nucleon Generalized Parton Distributions (GPDs), and providing an access to its Gravitational Form Factors. Furthermore, positron beams offer the possibility of alternative tests of the Standard Model through the search of a dark photon or the precise measurement of electroweak couplings. This letter proposes to develop an experimental positron program at JLab to perform unique high impact measurements with respect to the two-photon exchange problem, the determination of the proton and the neutron GPDs, and the search for the $A^{\prime}$ dark photon.

nucl-ex

Change-over of carrier type and magneto-transport property in Cu doped Bi2Te3 Topological Insulators

Structural, resistivity, thermoelectric power and magneto-transport properties of Cu doped Bi2Te3 topological insulators have been investigated. The occurrence of the tuning of charge carriers from n type to p type by Cu doping at Te sites of Bi2Te3 is observed both from Hall effect and thermoelectric power measurements. Carrier mobility decreases with the doping of Cu which provides evidence of the movement of Fermi level from bulk conduction band to the bulk valence band. Thermoelectric power also increaseswith doping of Cu.Moreover linear magnetoresistance (LMR) has been observed at high magnetic field in pure Bi2Te3 which is associated to the gapless topological surface states protected by time reversal symmetry (TRS), whereas doping of Cu breaks TRS and an opening of band gap occurs which quenches the LMR.

cond-mat.mtrl-sci