SearcharxivSearch

arXiv subjects

T. Peitzmann

Publications and source records attributed to T. Peitzmann.

At least 19 recordsLinked to original sources

Reconstruction of proton relative stopping power with a granular calorimeter detector model

Proton computed tomography (pCT) aims to facilitate precise dose planning for hadron therapy, a promising and effective method for cancer treatment. Hadron therapy utilizes protons and heavy ions to deliver well focused doses of radiation, leveraging the Bragg peak phenomenon to target tumors while sparing healthy tissues. The Bergen pCT Collaboration aims to develop a novel pCT scanner, and accompanying reconstruction algorithms to overcome current limitations. This paper focuses on advancing the track- and image reconstruction algorithms, thereby enhancing the precision of the dose planning and reducing side effects of hadron therapy. A neural network aided track reconstruction method is presented.

physics.comp-ph

Performance of the electromagnetic and hadronic prototype segments of the ALICE Forward Calorimeter

We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$\lambda_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS and SPS beam lines with hadron (electron) beams up to energies of 350 (300) GeV. Regarding FoCal-E, we report a comprehensive analysis of its response to minimum ionizing particles across all pad layers. The longitudinal shower profile of electromagnetic showers is measured with a layer-wise segmentation of 1$X_0$. As a projection to the performance of the final detector in electromagnetic showers, we demonstrate linearity in the full energy range, and show that the energy resolution fulfills the requirements for the physics needs. Additionally, the performance to separate two-showers events was studied by quantifying the transverse shower width. Regarding FoCal-H, we report a detailed analysis of the response to hadron beams between 60 and 350 GeV. The results are compared to simulations obtained with a Geant4 model of the test beam setup, which in particular for FoCal-E are in good agreement with the data. The energy resolution of FoCal-E was found to be lower than 3% at energies larger than 100 GeV. The response of FoCal-H to hadron beams was found to be linear, albeit with a significant intercept that is about factor 2 larger than in simulations. Its resolution, which is non-Gaussian and generally larger than in simulations, was quantified using the FWHM, and decreases from about 16% at 100 GeV to about 11% at 350 GeV. The discrepancy to simulations, which is particularly evident at low hadron energies, needs to be further investigated.

physics.ins-det

A Large-Scale Pad-Sensor Based Prototype of the Silicon Tungsten Electromagnetic Calorimeter for the Forward Direction in ALICE at LHC

We constructed a large-scale electromagnetic calorimeter prototype as a part of the Forward Calorimeter upgrade project (FoCal) for the ALICE experiment at the Large Hadron Collider (LHC). The prototype, also known as ``Mini FoCal'', consists of 20 layers of silicon pad sensors and tungsten alloy plates with printed circuit boards and readout electronics. The constructed detector was tested at the test beam facility of the Super Proton Synchrotron (SPS) at CERN. We obtain an energy resolution of about 4.3% for electron beams at both 150 and 250 GeV/$c$, which is consistent with realistic detector response simulations. Longitudinal profiles of electromagnetic shower were also measured and found to agree with the simulations. The same prototype detector was installed in the ALICE experimental area about 7.5m away from the interaction point. It was used to measure inclusive electromagnetic cluster energy distributions and neutral-pion candidate invariant mass distributions for pseudo-rapidity of $\eta$=3.7-4.5 in proton-proton collisions at $\sqrt{s}$ = 13 TeV at LHC. The measured distributions in different $\eta$ regions are similar to those obtained from PYTHIA simulations.

physics.ins-det

Performance of the Electromagnetic Pixel Calorimeter Prototype EPICAL-2

The first evaluation of an ultra-high granularity digital electromagnetic calorimeter prototype using 1.0-5.8 GeV/c electrons is presented. The $25\times10^6$ pixel detector consists of 24 layers of ALPIDE CMOS MAPS sensors, with a pitch of around 30~$\mu$m, and has a depth of almost 20 radiation lengths of tungsten absorber. Ultra-thin cables allow for a very compact design. The properties that are critical for physics studies are measured: electromagnetic shower response, energy resolution and linearity. The stochastic energy resolution is comparable with the state-of-the art resolution for a Si-W calorimeter, with data described well by a simulation model using GEANT and Allpix$^2$. The performance achieved makes this technology a good candidate for use in the ALICE FoCal upgrade, and in general demonstrates the strong potential for future applications in high-energy physics.

physics.ins-det

Snowmass 2021/22 Letter of Interest: A Forward Calorimeter at the LHC

A forward electromagnetic and hadronic calorimeter (FoCal) was proposed as an upgrade to the ALICE experiment, to be installed during LS3 for data-taking in 2027--2029 at the LHC. The FoCal extends the scope of ALICE, which was designed for the comprehensive study of hot and dense partonic matter, by adding new capabilities to explore the small-$x$ parton structure of nucleons and nuclei. The primary objective of the FoCal is high-precision inclusive measurement of direct photons and jets, as well as coincident gamma-jet and jet-jet measurements, in pp and p--Pb collisions. These measurements by FoCal constitute an essential part of a comprehensive small-$x$ program at the LHC down to $x\sim10^{-6}$ and over a large range of $Q^2$ with a broad array of complementary probes, comprising -- in addition to the photon measurements by FoCal and LHCb -- Drell-Yan and open charm measurements planned by LHCb, as well as photon-induced reactions performed by all LHC experiments.

hep-ex

Results from the EPICAL-2 Ultra-High Granularity Electromagnetic Calorimeter Prototype

A prototype of a new type of calorimeter has been designed and constructed, based on a silicon-tungsten sampling design using pixel sensors with digital readout. It makes use of the Alpide MAPS sensor developed for the ALICE ITS upgrade. A binary readout is possible due to the pixel size of $\approx 30 \times 30 \, \mu \mathrm{m}^2$. This prototype has been successfully tested with cosmic muons and with test beams at DESY and the CERN SPS. We report on performance results obtained at DESY, showing good energy resolution and linearity, and compare to detailed MC simulations. Also shown are preliminary results of the high-energy performance as measured at the SPS. The two-shower separation capabilities are discussed.

physics.ins-det

Design and Performance of a Silicon Tungsten Calorimeter Prototype Module and the Associated Readout

We describe the details of a silicon-tungsten prototype electromagnetic calorimeter module and associated readout electronics. Detector performance for this prototype has been measured in test beam experiments at the CERN PS and SPS accelerator facilities in 2015/16. The results are compared to those in Monte Carlo Geant4 simulations. This is the first real-world demonstration of the performance of a custom ASIC designed for fast, lower-power, high-granularity applications.

physics.ins-det

The FoCal prototype - an extremely fine-grained electromagnetic calorimeter using CMOS pixel sensors

A prototype of a Si-W EM calorimeter was built with Monolithic Active Pixel Sensors as the active elements. With a pixelsize of 30 $\mu$m it allows digital calorimetry, i.e. the particles' energy is determined by counting pixels, not by measuring the energy deposited. Although of modest size, with a width of only four Moliere radii, it has 39 million pixels. We describe the construction and tuning of the prototype and present results from beam tests and compare them with predictions of GEANT-based Monte Carlo simulations. We show the shape of showers caused by electrons in unprecedented detail. Results for energy and position resolution will also be given.

physics.ins-det

Impact of residual contamination on inclusive and direct photon flow

Direct photon flow is measured by subtracting the contribution of decay photon flow from the measured inclusive photon flow via the double ratio $R_{\rm \gamma}$, which defines the excess of direct over decay photons. The inclusive photon sample is affected by a modest contamination from different background sources, which is often ignored in measurements. However, due to the sensitivity of the direct photon measurement even a residual contamination may significantly bias the extracted direct photon flow. In particular, for measurements using photon conversions, which are very powerful at low transverse momentum, these effects can be substantial. Assuming three different types of correlated background contributions we demonstrate using the Therminator2 event generator that the impact of the contamination on the magnitude of direct photon flow can be on the level of $50\%$, even if the purity of the inclusive photon sample is about $97\%$. Future measurements should attempt to account for the contamination by measuring the background contributions and subtracting them from the inclusive photon flow.

nucl-ex

Prototype studies for a forward EM calorimeter in ALICE

A forward electromagnetic calorimeter (FoCal) based on SiW technology is being considered as a possible upgrade to the ALICE detector. This device should in particular feature an extremely high granularity allowing gamma/pi0 discrimination out to very high momenta. The main option considered for the high granularity layers is the use of CMOS pixel sensors. We will discuss the motivation and design principles of the proposed calorimeter and will then focus on the experience gained with a full CMOS-pixel calorimeter prototype. Preliminary results of this device show very good capabilities for shower profile measurements, and reasonable results for linearity and resolution, which are limited by the currently incomplete calibration.

physics.ins-det

The ridge laboratory

Mechanisms proposed to explain the jet-related correlation of long range in rapidity (the ridge) observed in high-energy heavy-ion collisions are reviewed. Limitations of a model using the combined effect of transverse flow and a direction bias of partons suffering energy loss are discussed. The influence of the time scale of the correlation mechanism on the rapidity range is investigated.

nucl-th

Photon Physics in Heavy Ion Collisions at the LHC

Various pion and photon production mechanisms in high-energy nuclear collisions at RHIC and LHC are discussed. Comparison with RHIC data is done whenever possible. The prospect of using electromagnetic probes to characterize quark-gluon plasma formation is assessed.

hep-ph

Influence of hydrodynamics on the interpretation of the high $p_{T}$ hadron suppression at RHIC

A hybrid parameterization including contributions of hydrodynamics and of expectations from the spectral shape observed in p+p collisions is introduced. This parameterization can successfully describe identified hadron spectra over a wide range of $p_{T}$ in Au+Au reactions at $\sqrt{s_{NN}}$ = 200 GeV for all centralities. The parameters of the hydrodynamic source compare reasonably well to other attempts to describe the spectra. The description is obtained using one universal suppression factor of the hard scattering component independent of $p_{T}$ and hadron species. For the fit results obtained the observed nuclear modification factor for the different particles converges to a universal suppression behavior for $p_{T} > 6 \mathrm{GeV}/c$.

nucl-th

Hydrodynamic description of spectra at high transverse mass in ultrarelativistic heavy ion collisions

Transverse mass spectra of pions and protons measured in central collisions of heavy ions at the SPS and at RHIC are compared to a hydrodynamic parameterization. While the chemical temperature needed at RHIC is significantly higher compared to SPS, the spectra may be described using kinetic freeze-out parameters which are similar for both beam energies. At RHIC either the temperature or the flow velocity is higher, but the data provide no unambiguous proof for much stronger transverse flow. The contribution of such hydrodynamic emission at high transverse momenta is investigated in detail. It is shown that hydrodynamics may be relevant up to relatively high transverse momenta. The importance of the velocity profile used in this context is highlighted.

nucl-th

Summary of Results on Hard Probes

Results on observables related to hard scattering processes as presented at this conference are reviewed. This includes in particular measurements related to jet quenching, a phenomenon which has been predicted as a signature for the hot and dense early phase of strongly interacting matter.

nucl-ex

High Energy Beam Test of the PHENIX Lead-Scintillator EM Calorimeter

In the PHENIX experiment at RHIC, the electro-magnetic calorimeter plays an important role in both the heavy-ion and spin physics programs for which it was designed. In order to measure its performance in the energy range up to 80GeV, a beam test was performed at the CERN-SPS H6 beam line. We describe the beam test and present results on calorimeter performance with pion and electron beams.

nucl-ex

Prototype tests for the ALICE TRD

A Transition Radiation Detector (TRD) has been designed to improve the electron identification and trigger capability of the ALICE experiment at the Large Hadron Collider (LHC) at CERN. We present results from tests of a prototype of the TRD concerning pion rejection for different methods of analysis over a momentum range from 0.7 to 2 GeV/c. We investigate the performance of different radiator types, composed of foils, fibres and foams.

nucl-ex