SearcharxivSearch

arXiv subjects

T. S. Watson

Publications and source records attributed to T. S. Watson.

5 recordsLinked to original sources

Remeasurement of the $^{239}$Pu(n,f)/$^{235}$U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber Using Vapor-deposited Targets

The NIFFTE fission Time Projection Chamber (fissionTPC) has been used to measure the $^{239}$Pu(n,f)/$^{235}$U(n,f) cross-section ratio for neutron-induced fission in the range of 0.1 - 100 MeV, with high precision. A white neutron source was provided by the Los Alamos Neutron Science Center, where the experiment was conducted as a remeasurement to evaluate a roughly 2% discrepancy of the previous fissionTPC results with ENDF/B-VIII.0. A detailed accounting of measurement uncertainties was performed, based on the fissionTPC's novel ability to provide three-dimensional reconstruction of fission-fragment ionization profiles. Current results obtained using a vapor-deposited, highly uniform $^{239}$Pu target, in comparison to the measurement published in 2021, where a $^{239}$Pu electroplated target was used, are presented and discussed. The remeasurement presented here is in agreement with the previous fissionTPC result within measurement uncertainties.

nucl-ex

Measurement of flavor asymmetry of light-quark sea in the proton with Drell-Yan dimuon production in $p+p$ and $p+d$ collisions at 120 GeV

Evidence for a flavor asymmetry between the $\bar u$ and $\bar d$ quark distributions in the proton has been found in deep-inelastic scattering and Drell-Yan experiments. The pronounced dependence of this flavor asymmetry on $x$ (fraction of nucleon momentum carried by partons) observed in the Fermilab E866 Drell-Yan experiment suggested a drop of the $\bar d\left(x\right) / \bar u\left(x\right)$ ratio in the $x > 0.15$ region. We report results from the SeaQuest Fermilab E906 experiment with improved statistical precision for $\bar d\left(x\right) / \bar u\left(x\right)$ in the large $x$ region up to $x=0.45$ using the 120 GeV proton beam. Two different methods for extracting the Drell-Yan cross section ratios, $σ^{pd} /2 σ^{pp}$, from the SeaQuest data give consistent results. The $\bar{d}\left(x\right) / \bar{u}\left(x\right)$ ratios and the $\bar d\left(x\right) - \bar u\left(x\right)$ differences are deduced from these cross section ratios for $0.13 < x < 0.45$. The SeaQuest and E866/NuSea $\bar{d}\left(x\right) / \bar{u}\left(x\right)$ ratios are in good agreement for the $x\lesssim 0.25$ region. The new SeaQuest data, however, show that $\bar d\left(x\right)$ continues to be greater than $\bar u\left(x\right)$ up to the highest $x$ value ($x = 0.45$). The new results on $\bar{d}\left(x\right) / \bar{u}\left(x\right)$ and $\bar{d}\left(x\right) - \bar{u}\left(x\right)$ are compared with various parton distribution functions and theoretical calculations.

hep-ph

Measurement of material isotopics and atom number ratio with alpha-particle spectroscopy for the NIFFTE fission Time Projection Chamber actinide target

We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is intended to provide an absolute normalization of the measured fission cross-section ratio. The Pu-239/U-235 atom number ratio was measured with a combination of mass spectrometry and alpha-spectroscopy with a planar silicon detector with uncertainties of less than 1%.

nucl-ex

Measurement of the $^{239}$Pu(n,f)/$^{235}$U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber

The $^{239}$Pu(n,f)/$^{235}$U(n,f) cross-section ratio has been measured with the fission Time Projection Chamber (fissionTPC) from 100 keV to 100 MeV. The fissionTPC provides three-dimensional reconstruction of fission-fragment ionization profiles, allowing for a precise quantification of measurement uncertainties. The measurement was performed at the Los Alamos Neutron Science Center which provides a pulsed white source of neutrons. The data are recommended to be used as a cross-section ratio shape. A discussion of the status of the absolute normalization and comparisons to ENDF evaluations and previous measurements is included.

nucl-ex

Neutron Induced Fission Fragment Angular Distributions, Anisotropy, and Linear Momentum Transfer Measured with the NIFFTE Fission Time Projection Chamber

The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) collaboration has performed measurements with a fission time projection chamber (fissionTPC) to study the fission process by reconstructing full three-dimensional tracks of fission fragments and other ionizing radiation. The amount of linear momentum imparted to the fissioning nucleus by the incident neutron can be inferred by measuring the opening angle between the fission fragments. Using this measured linear momentum, fission fragment angular distributions can be converted to the center-of-mass frame for anisotropy measurements. Angular anisotropy is an important experimental observable for understanding the quantum mechanical state of the fissioning nucleus and vital to determining detection efficiency for cross section measurements. Neutron linear momentum transfer to fissioning $^{235}$U, $^{238}$U, and $^{239}$Pu and fission fragment angular anisotropy of $^{235}$U and $^{238}$U as a function of neutron energies in the range 130 keV--250 MeV are presented.

nucl-ex