SearcharxivSearch

arXiv subjects

T. Shimada

Publications and source records attributed to T. Shimada.

At least 19 recordsLinked to original sources

The dipole strength distribution of $^8$He and decay characteristics

The weak binding and spatially extended neutron densities characteristic of drip-line nuclei give rise to a distinctive low-energy dipole response. The drip-line nucleus $^8$He is the most neutron-rich bound nucleus with a mass-to-charge ratio of $A/Z=4$. We measure the dipole response of $^8$He, including for the first time the four-neutron decay channel. A total dipole strength of $\sum B(E1)(E^*<15$~MeV$)=0.95(16)~e^2$fm$^2$ and a dipole polarizability of $\alpha_D = 0.61(1)$~fm$^3$ are extracted from the differential Coulomb-excitation cross section and compared to state-of-the-art theoretical calculations employing coupled cluster and three-body approaches. We find that the dipole continuum is dominated, even at high excitation energies well above the $4n$ decay threshold, by two-neutron emission, pointing to a $^6$He$+2n$ structure of the excited dipole mode. No indication was found for a $4n$ final-state correlation, while pronounced $nn$ and $^6$He-$n$ final-state correlations are apparent.

nucl-ex

Direct observation of three-neutron emission from $^7$He$^*$ and the search for the trineutron

Three-neutron emission from $^7$He has been directly measured for the first time, following neutron knockout from a $^8$He beam at 156 MeV/nucleon. A resonance-like structure at $2.08(4)$ MeV above the $^4$He+$3n$ threshold [$E_x=2.68(4)$ MeV] with a width of $3.9(2)$ MeV was observed and deduced to arise predominately from the predicted $J^{\pi}=3/2^{-}_2$ level. The three-neutron invariant-mass spectrum was reconstructed and found to peak at around 1 MeV and could, through complete simulations incorporating neutron-neutron correlations, be very well described by the sequential decay of $^7$He$^*$ via the $2_1^+$ excited state of $^6$He. No evidence was found for any significant three-neutron correlations beyond those expected from well-established two-body interactions, including a trineutron resonance.

nucl-ex

Validation of the $^{10}\mathrm{Be}$ Ground-State Molecular Structure Using $^{10}\mathrm{Be}(p,p\alpha)^{6}\mathrm{He}$ Triple Differential Reaction Cross-Section Measurements

The cluster structure of the neutron-rich isotope $^{10}$Be has been probed via the $(p,p\alpha)$ reaction at 150 MeV/nucleon in inverse kinematics and in quasifree conditions. The populated states of $^{6}$He residues were investigated through missing mass spectroscopy. The triple differential cross-section for the ground-state transition was extracted for quasifree angle pairs ($\theta_{p}$, $\theta_{\alpha}$) and compared to distorted-wave impulse approximation reaction calculations performed in a microscopic framework using successively the Tohsaki-Horiuchi-Schuck-R\"opke product wave-function and the wave-function deduced from Antisymmetrized Molecular Dynamics calculations. The remarkable agreement between calculated and measured cross-sections in both shape and magnitude validates the molecular structure description of the $^{10}$Be ground-state, configured as an $\alpha$-$\alpha$ core with two valence neutrons occupying $\pi$-type molecular orbitals.

nucl-ex

Development of a Negative Ion Micro TPC Detector with SF$_{6}$ Gas for the Directional Dark Matter Search

A negative ion micro time projection chamber (NI$\mu$TPC) was developed and its performance studied. An NI$\mu$TPC is a novel technology that enables the measurement of absolute $z$ coordinates for self-triggering TPCs. This technology provides full-fiducialization analysis, which is not possible with conventional gaseous TPCs, and is useful for directional dark matter searches in terms of background rejection and the improvement of the angular resolution. The developed NI$\mu$TPC prototype had a detection volume of 12.8 $\times$ 25.6 $\times$ 144 mm$^{3}$. The absolute $z$ coordinate was determined with a location accuracy of 16 mm using minority carrieres of SF$_{5}^{-}$. Simultaneously, there was a successful reconstruction of the three-dimensional (3D) tracks with a spatial resolution of 130 $\mu\rm{m}$. This is the first demonstration of 3D tracking with the detection of absolute $z$ coordinates, and it is an important step in improving the sensitivity of directional dark matter searches.

physics.ins-det

Study of multi-neutron systems with SAMURAI spectrometer

The tetraneutron has been drawing the attention of the nuclear physics community for decades, but a firm conclusion on its existence and properties is still far from being reached despite many experimental and theoretical efforts. New measurements have recently been performed at RIBF with the SAMURAI spectrometer by applying complementary reaction probes, which will help to pin down the properties of this four-neutron system.

nucl-ex

Hybridization gap formation in the Kondo insulator YbB$_{12}$ observed using time-resolved photoemission spectroscopy

A detailed low-energy electronic structure of a Kondo insulator YbB$_{12}$ was revealed by a synergetic combination of ultrahigh-resolution laser photoemission spectroscopy (PES) and time-resolved PES. The former confirmed a 25-meV pseudogap corresponding to the Kondo temperature of this material, and more importantly, it revealed that a 15-meV gap and a Kondo-peak feature developed below a crossover temperature $T^\ast \sim 110$ K. In harmony with this, the latter discovered a very long recombination time exceeding 100 ps below $\sim$$T^\ast$. This is a clear manifestation of photoexcited carriers due to the bottleneck in the recovery dynamics, which is interpreted as a developing hybridization gap of a hard gap.

cond-mat.str-el

Emergent photovoltage on SmB6 surface upon bulk-gap evolution revealed by pump-and-probe photoemission spectroscopy

Recent studies suggest that an exemplary Kondo insulator SmB6 belongs to a new class of topological insulators (TIs), in which non-trivial spin-polarized metallic states emerge on surface upon the formation of Kondo hybridization gap in the bulk. Remarkably, the bulk resistivity reaches more than 20 Ohm cm at 4 K, making SmB6 a candidate for a so-called bulk-insulating TI. We here investigate optical-pulse responses of SmB6 by pump-and-probe photoemission spectroscopy. Surface photovoltage effect is observed below ~90 K. This indicates that an optically-active band bending region develops beneath the novel metallic surface upon the bulk-gap evolution. The photovoltaic effect persists for >200 microsec, which is long enough to be detected by electronics devices, and could be utilized for optical gating of the novel metallic surface.

cond-mat.str-el

Localized guided-mode and cavity-mode double resonance in photonic crystal nanocavities

We investigate the use of guided modes bound to defects in photonic crystals for achieving double resonances. Photoluminescence enhancement by more than three orders of magnitude has been observed when the excitation and emission wavelengths are simultaneously in resonance with the localized guided mode and cavity mode, respectively. We find that the localized guided modes are relatively insensitive to the size of the defect for one of the polarizations, allowing for flexible control over the wavelength combinations. This double resonance technique is expected to enable enhancement of photoluminescence and nonlinear wavelength conversion efficiencies in a wide variety of systems.

physics.optics

Single-Shot 60 dB Dynamic Range Laser Contrast Measurement Using Self-Referencing Spectral Interferometry

High dynamic range contrast measurement of laser pulses is typically obtained by cross-correlating the laser pulse with a self-generated reference laser pulse directly in the temporal domain. Alternatively, it is also possible to measure the spectral interferogram of the laser pulse with the references pulse in the spectral domain, from which the high dynamic range contrast measurement can be extracted using inverse Fourier-transformation. Here, we demonstrate single-shot 60 dB dynamic range laser contrast measurement by inverse Fourier-transforming the measured spectral interferogram into temporal domain. The result directly provides the cross-correlation of the laser pulse with the reference pulse provided there is enough time-delay imposed between the laser and reference pulses. Then method is cross-calibrated by measuring known pre-pulses along with scanning third-order auto-correlator measurements.

physics.optics

Gate-controlled generation of optical pulse trains using individual carbon nanotubes

We report on optical pulse-train generation from individual air-suspended carbon nanotubes under an application of square-wave gate voltages. Electrostatically-induced carrier accummulation quenches photoluminescence, while a voltage sign reversal purges those carriers, resetting the nanotubes to become luminescent temporarily. Frequency domain measurements reveal photoluminescence recovery with characteristic frequencies that increase with excitation laser power, showing that photoexcited carriers quench the emission in a self-limiting manner. Time-resolved measurements directly confirm the presence of an optical pulse train sychronized to the gate voltage signal, and flexible control over pulse timing and duration is demonstrated.

cond-mat.mes-hall

Ultralow mode-volume photonic crystal nanobeam cavities for high efficiency coupling to individual carbon nanotube emitters

We report on high efficency coupling of individual air-suspended carbon nanotubes to silicon photonic crystal nanobeam cavities. Photoluminescence images of dielectric- and air-mode cavities reflect their distinctly different mode profiles and show that fields in the air are important for coupling. We find that the air-mode cavities couple more efficiently, and estimated spontaneous emission coupling factors reach a value as high as 0.85. Our results demonstrate advantages of ultralow mode-volumes in air-mode cavities for coupling to low-dimensional nanoscale emitters.

cond-mat.mes-hall

Scaling of laser-driven ion energies in the relativistic transparent regime

Laser-driven ions have compelling properties and their potential use for medical applications has attracted a huge global interest. One of the major challenges of these applications is generating beams of the required energies. To date, there has been no systematic study of the effect of laser intensity on the generation of laser-driven ions from ultrathin foils during relativistic transparency. Here we present a scaling for ion energies with respect to the on-target laser intensity and in considering target thickness we find an optimum thickness closely related to the experimentally observed relativistic transparency. A steep linear scaling with the normalized laser amplitude a0 has been measured and verified with PIC simulations. In contrast to TNSA, this scaling is much steeper and has been measured for ions with Z > 1. Following our results, ion energies exceeding 100MeV/amu are already accessible with currently available laser systems enabling realization of numerous advanced applications

physics.plasm-ph

Spontaneous exciton dissociation in carbon nanotubes

Simultaneous photoluminescence and photocurrent measurements on individual single-walled carbon nanotubes reveal spontaneous dissociation of excitons into free electron-hole pairs. Correlation of luminescence intensity and photocurrent shows that a significant fraction of excitons are dissociating during their relaxation into the lowest exciton state. Furthermore, the combination of optical and electrical signals also allows for extraction of the absorption cross section and the oscillator strength. Our observations explain the reasons for photoconductivity measurements in single-walled carbon nanotubes being straightforward despite the large exciton binding energies.

cond-mat.mes-hall

Optical control of individual carbon nanotube light emitters by spectral double resonance in silicon microdisk resonators

Single-walled carbon nanotubes have advantages as a nanoscale light source compatible with silicon photonics because they show room-temperature luminescence at telecom-wavelengths and can be directly synthesized on silicon substrates. Here we demonstrate integration of individual light-emitting carbon nanotubes with silicon microdisk resonators. Photons emitted from nanotubes are efficiently coupled to whispering gallery modes, circulating within the disks and lighting up their perimeters. Furthermore, we control such emission by tuning the excitation wavelength in and out of resonance with higher order modes in the same disk. Our results open up the possibilities of using nanotube emitters embedded in photonic circuits that are individually addressable through spectral double resonance.

cond-mat.mes-hall

Enhancement of carbon nanotube photoluminescence by photonic crystal nanocavities

Photonic crystal nanocavities are used to enhance photoluminescence from single-walled carbon nanotubes. Micelle-encapsulated nanotubes are deposited on nanocavities within Si photonic crystal slabs and confocal microscopy is used to characterize the devices. Photoluminescence spectra and images reveal nanotube emission coupled to nanocavity modes. The cavity modes can be tuned throughout the emission wavelengths of carbon nanotubes, demonstrating the ability to enhance photoluminescence from a variety of chiralities.

cond-mat.mes-hall

Gas gun shock experiments with single-pulse x-ray phase contrast imaging and diffraction at the Advanced Photon Source

The highly transient nature of shock loading and pronounced microstructure effects on dynamic materials response call for {\it in situ}, temporally and spatially resolved, x-ray-based diagnostics. Third-generation synchrotron x-ray sources are advantageous for x-ray phase contrast imaging (PCI) and diffraction under dynamic loading, due to their high photon energy, high photon fluxes, high coherency, and high pulse repetition rates. The feasibility of bulk-scale gas gun shock experiments with dynamic x-ray PCI and diffraction measurements was investigated at the beamline 32ID-B of the Advanced Photon Source. The x-ray beam characteristics, experimental setup, x-ray diagnostics, and static and dynamic test results are described. We demonstrate ultrafast, multiframe, single-pulse PCI measurements with unprecedented temporal ($<$100 ps) and spatial ($\sim$2 $μ$m) resolutions for bulk-scale shock experiments, as well as single-pulse dynamic Laue diffraction. The results not only substantiate the potential of synchrotron-based experiments for addressing a variety of shock physics problems, but also allow us to identify the technical challenges related to image detection, x-ray source, and dynamic loading.

cond-mat.other

Quantification of group chasing and escaping process

We study a simple group chase and escape model by introducing new parameters with which configurations of chasing and escaping in groups are classified into three characteristic patterns. In particular, the parameters distinguish two essential configurations: a one-directional formation of chasers and escapees, and an escapee surrounded by chasers. In addition, pincer movements and aggregating processes of chasers and escapees are also quantified. Appearance of these configurations highlights efficiency of hunting during chasing and escaping.

physics.comp-ph

Gate-induced blueshift and quenching of photoluminescence in suspended single-walled carbon nanotubes

Gate-voltage effects on photoluminescence spectra of suspended single-walled carbon nanotubes are investigated. Photoluminescence microscopy and excitation spectroscopy are used to identify individual nanotubes and to determine their chiralities. Under an application of gate voltage, we observe slight blueshifts in the emission energy and strong quenching of photoluminescence. The blueshifts are similar for different chiralities investigated, suggesting extrinsic mechanisms. In addition, we find that the photoluminescence intensity quenches exponentially with gate voltage.

cond-mat.mes-hall