SearcharxivSearch

arXiv subjects

T. Shishido

Publications and source records attributed to T. Shishido.

2 recordsLinked to original sources

Development of advanced photon calibrator for Kamioka gravitational wave detector (KAGRA)

The Kamioka Gravitational wave detector (KAGRA) cryogenic gravitational-wave observatory has commenced joint observations with the worldwide gravitational wave detector network. Precise calibration of the detector response is essential for accurately estimating parameters of gravitational wave sources. A photon calibrator is a crucial calibration tool used in laser interferometer gravitational-wave observatory, Virgo, and KAGRA, and it was utilized in joint observation 3 with GEO600 in Germany in April 2020. In this paper, KAGRA implemented three key enhancements: a high-power laser, a power stabilization system, and remote beam position control. KAGRA employs a 20 W laser divided into two beams that are injected onto the mirror surface. By utilizing a high-power laser, the response of the detector at kHz frequencies can be calibrated. To independently control the power of each laser beam, an optical follower servo was installed for power stabilization. The optical path of the photon calibrator beam positions was controlled using pico-motors, allowing for the characterization of the detector rotation response. Additionally, a telephoto camera and quadrant photodetectors were installed to monitor beam positions, and beam position control was implemented to optimize the mirror response. In this paper, we discuss the statistical errors associated with the measurement of relative power noise. We also address systematic errors related to the power calibration model of the photon calibrator and the simulation of elastic deformation effects using finite element analysis. Ultimately, we have successfully reduced the total systematic error from the photon calibrator to 2.0 /%.

astro-ph.IM

Development of Superconducting Linac for the Kek/Jaeri Joint Project

The JAERI/KEK Joint Project for the high-intensity proton accelerator facility has been proposed with a superconducting (SC) linac option from 400 MeV to 600MeV. System design of the SC linac has been carried out based on the equipartitioning concept. The SC linac is planned to use as an injector to a 3GeV rapid cycling synchrotron (RCS) for spallation neutron source after it meets requirement to momentum spread less than +-0.1%. In the R&D work for SC cavities, vertical tests of single-cell and 5 cell cavities were performed. Experiments on multi-cell (5 cell) cavities of b=0.50 and b=0.89 at 2K were carried out with values of maximum electric surface peak fields of 23MV/m and 31MV/m, respectively. A model describing dynamic Lorentz detuning for SC cavities has been developed for pulse mode operation. Validity of the model was confirmed experimentally to simulate the performance.

physics.acc-ph