SearcharxivSearch

arXiv subjects

T. Teraji

Publications and source records attributed to T. Teraji.

At least 19 recordsLinked to original sources

Diamond quantum magnetometer with dc sensitivity of < 10 pT Hz$^{-1/2}$ toward measurement of biomagnetic field

We present a sensitive diamond quantum sensor with a magnetic field sensitivity of $9.4 \pm 0.1~\mathrm{pT/\sqrt{Hz}}$ in a near-dc frequency range of 5 to 100~Hz. This sensor is based on the continuous-wave optically detected magnetic resonance of an ensemble of nitrogen-vacancy centers along the [111] direction in a diamond (111) single crystal. The long $T_{2}^{\ast} \sim 2~\mathrm{μs}$ in our diamond and the reduced intensity noise in laser-induced fluorescence result in remarkable sensitivity among diamond quantum sensors. Based on an Allan deviation analysis, we demonstrate that a sub-picotesla field of 0.3~pT is detectable by interrogating the magnetic field for a few thousand seconds. The sensor head is compatible with various practical applications and allows a minimum measurement distance of about 1~mm from the sensing region. The proposed sensor facilitates the practical application of diamond quantum sensors.

quant-ph

Hyperpolarisation of external nuclear spins using nitrogen-vacancy centre ensembles

The nitrogen-vacancy (NV) centre in diamond has emerged as a candidate to non-invasively hyperpolarise nuclear spins in molecular systems to improve the sensitivity of nuclear magnetic resonance (NMR) experiments. Several promising proof of principle experiments have demonstrated small-scale polarisation transfer from single NVs to hydrogen spins outside the diamond. However, the scaling up of these results to the use of a dense NV ensemble, which is a necessary prerequisite for achieving realistic NMR sensitivity enhancement, has not yet been demonstrated. In this work, we present evidence for a polarising interaction between a shallow NV ensemble and external nuclear targets over a micrometre scale, and characterise the challenges in achieving useful polarisation enhancement. In the most favourable example of the interaction with hydrogen in a solid state target, a maximum polarisation transfer rate of $\approx 7500$ spins per second per NV is measured, averaged over an area containing order $10^6$ NVs. Reduced levels of polarisation efficiency are found for liquid state targets, where molecular diffusion limits the transfer. Through analysis via a theoretical model, we find that our results suggest implementation of this technique for NMR sensitivity enhancement is feasible following realistic diamond material improvements.

cond-mat.mes-hall

Determining the position of a single spin relative to a metallic nanowire

The nanoscale localization of individual paramagnetic defects near an electrical circuit is an important step for realizing hybrid quantum devices with strong spin-microwave photon coupling. Here, we demonstrate the fabrication of an array of individual NV centers in diamond near a metallic nanowire deposited on top of the substrate. We determine the relative position of each NV center with $\sim$10\,nm accuracy, using it as a vector magnetometer to measure the field generated by passing a dc current through the wire.

quant-ph

Comparison of different methods of nitrogen-vacancy layer formation in diamond for widefield quantum microscopy

Thin layers of near-surface nitrogen-vacancy (NV) defects in diamond substrates are the workhorse of NV-based widefield magnetic microscopy, which has applications in physics, geology and biology. Several methods exist to create such NV layers, which generally involve incorporating nitrogen atoms (N) and vacancies (V) into the diamond through growth and/or irradiation. While there have been detailed studies of individual methods, a direct side-by-side experimental comparison of the resulting magnetic sensitivities is still missing. Here we characterise, at room and cryogenic temperatures, $\approx100$ nm thick NV layers fabricated via three different methods: 1) low-energy carbon irradiation of N-rich high-pressure high-temperature (HPHT) diamond, 2) carbon irradiation of $δ$-doped chemical vapour deposition (CVD) diamond, 3) low-energy N$^+$ or CN$^-$ implantation into N-free CVD diamond. Despite significant variability within each method, we find that the best HPHT samples yield similar magnetic sensitivities (within a factor 2 on average) to our $δ$-doped samples, of $<2$~$μ$T Hz$^{-1/2}$ for DC magnetic fields and $<100$~nT Hz$^{-1/2}$ for AC fields (for a $400$~nm~$\times~400$~nm pixel), while the N$^+$ and CN$^-$ implanted samples exhibit an inferior sensitivity by a factor 2-5, at both room and low temperature. We also examine the crystal lattice strain caused by the respective methods and discuss the implications this has for widefield NV imaging. The pros and cons of each method, and potential future improvements, are discussed. This study highlights that low-energy irradiation of HPHT diamond, despite its relative simplicity and low cost, is a competitive method to create thin NV layers for widefield magnetic imaging.

physics.app-ph

The non-vanishing effect of detuning errors in dynamical decoupling based quantum sensing experiments

Characteristic dips appear in the coherence traces of a probe qubit when dynamical decoupling (DD) is applied in synchrony with the precession of target nuclear spins, forming the basis for nanoscale nuclear magnetic resonance (NMR). The frequency of the microwave control pulses is chosen to match the qubit transition but this can be detuned from resonance by experimental errors, hyperfine coupling intrinsic to the qubit, or inhomogeneous broadening. The detuning acts as an additional static field which is generally assumed to be completely removed in Hahn echo and DD experiments. Here we demonstrate that this is not the case in the presence of finite pulse-durations, where a detuning can drastically alter the coherence response of the probe qubit, with important implications for sensing applications. Using the electronic spin associated with a nitrogen-vacancy centre in diamond as a test qubit system, we analytically and experimentally study the qubit coherence response under CPMG and XY8 dynamical decoupling control schemes in the presence of finite pulse-durations and static detunings. Most striking is the splitting of the NMR resonance under CPMG, whereas under XY8 the amplitude of the NMR signal is modulated. Our work shows that the detuning error must not be neglected when extracting data from quantum sensor coherence traces.

quant-ph

Apparent delocalisation of the current flow in metallic wires observed with diamond nitrogen-vacancy magnetometry

We report on a quantitative analysis of the magnetic field generated by a continuous current running in metallic micro-wires fabricated on an electrically insulating diamond substrate. A layer of nitrogen-vacancy (NV) centres engineered near the diamond surface is employed to obtain spatial maps of the vector magnetic field, by measuring Zeeman shifts through optically-detected magnetic resonance spectroscopy. The in-plane magnetic field (i.e. parallel to the diamond surface) is found to be significantly weaker than predicted, while the out-of-plane field also exhibits an unexpected modulation. We show that the measured magnetic field is incompatible with Ampere's circuital law or Gauss's law for magnetism when we assume that the current is confined to the metal, independent of the details of the current density. This result was reproduced in several diamond samples, with a measured deviation from Ampere's law by as much as 94(6)\%. To resolve this apparent magnetic anomaly, we introduce a generalised description whereby the current is allowed to flow both above the NV sensing layer (including in the metallic wire) and below the NV layer (i.e. in the diamond). Inversion of the Biot-Savart law within this two-channel description leads to a unique solution for the two current densities, which completely explains the data, is consistent with the laws of classical electrodynamics and indicates a total NV-measured current that closely matches the electrically-measured current. However, this description also leads to the surprising conclusion that in certain circumstances the majority of the current appears to flow in the diamond substrate rather than in the metallic wire, and to spread laterally in the diamond by several micrometres away from the wire. No electrical conduction was observed between nearby test wires, ruling out a conventional conductivity effect. [...]

cond-mat.mes-hall

Microscopic imaging of elastic deformation in diamond via in-situ stress tensor sensors

The precise measurement of mechanical stress at the nanoscale is of fundamental and technological importance. In principle, all six independent variables of the stress tensor, which describe the direction and magnitude of compression/tension and shear stress in a solid, can be exploited to tune or enhance the properties of materials and devices. However, existing techniques to probe the local stress are generally incapable of measuring the entire stress tensor. Here, we make use of an ensemble of atomic-sized in-situ strain sensors in diamond (nitrogen-vacancy defects) to achieve spatial mapping of the full stress tensor, with a sub-micrometer spatial resolution and a sensitivity of the order of 1 MPa (corresponding to a strain of less than $10^{-6}$). To illustrate the effectiveness and versatility of the technique, we apply it to a broad range of experimental situations, including mapping the elastic stress induced by localized implantation damage, nano-indents and scratches. In addition, we observe surprisingly large stress contributions from functional electronic devices fabricated on the diamond, and also demonstrate sensitivity to deformations of materials in contact with the diamond. Our technique could enable in-situ measurements of the mechanical response of diamond nanostructures under various stimuli, with potential applications in strain engineering for diamond-based quantum technologies and in nanomechanical sensing for on-chip mass spectroscopy.

cond-mat.mtrl-sci

Magnetic noise from ultra-thin abrasively deposited materials on diamond

Sensing techniques based on the negatively charged nitrogen-vacancy (NV) centre in diamond have emerged as promising candidates to characterise ultra-thin and 2D materials. An outstanding challenge to this goal is isolating the contribution of 2D materials from undesired contributions arising from surface contamination, and changes to the diamond surface induced by the sample or transfer process. Here we report on such a scenario, in which the abrasive deposition of trace amounts of materials onto a diamond gives rise to a previously unreported source of magnetic noise. By deliberately scratching the diamond surface with macroscopic blocks of various metals (Fe, Cu, Cr, Au), we are able to form ultra-thin structures (i.e. with thicknesses down to $<1$\,nm), and find that these structures give rise to a broadband source of noise. Explanation for these effects are discussed, including spin and charge noise native to the sample and/or induced by sample-surface interactions, and indirect effects, where the deposited material affects the charge stability and magnetic environment of the sensing layer. This work illustrates the high sensitivity of NV noise spectroscopy to ultra-thin materials down to sub-nm regimes -- a key step towards the study of 2D electronic systems -- and highlights the need to passivate the diamond surface for future sensing applications in ultra-thin and 2D materials.

cond-mat.mes-hall

Proximity-induced artefacts in magnetic imaging with nitrogen-vacancy ensembles in diamond

Magnetic imaging with ensembles of nitrogen-vacancy (NV) centres in diamond is a recently developed technique that allows for quantitative vector field mapping. Here we uncover a source of artefacts in the measured magnetic field in situations where the magnetic sample is placed in close proximity (a few tens of nm) to the NV sensing layer. Using magnetic nanoparticles as a test sample, we find that the measured field deviates significantly from the calculated field, in shape, amplitude and even in sign. By modelling the full measurement process, we show that these discrepancies are caused by the limited measurement range of NV sensors combined with the finite spatial resolution of the optical readout. We numerically investigate the role of the stand-off distance to identify an artefact-free regime, and discuss an application to ultrathin materials. This work provides a guide to predict and mitigate proximity-induced artefacts that can arise in NV-based wide-field magnetic imaging, and also demonstrates that the sensitivity of these artefacts to the sample can make them a useful tool for magnetic characterisation.

cond-mat.mes-hall

Spin properties of dense near-surface ensembles of nitrogen-vacancy centres in diamond

We present a study of the spin properties of dense layers of near-surface nitrogen-vacancy (NV) centres in diamond created by nitrogen ion implantation. The optically detected magnetic resonance contrast and linewidth, spin coherence time, and spin relaxation time, are measured as a function of implantation energy, dose, annealing temperature and surface treatment. To track the presence of damage and surface-related spin defects, we perform in situ electron spin resonance spectroscopy through both double electron-electron resonance and cross-relaxation spectroscopy on the NV centres. We find that, for the energy ($4-30$~keV) and dose ($5\times10^{11}-10^{13}$~ions/cm$^2$) ranges considered, the NV spin properties are mainly governed by the dose via residual implantation-induced paramagnetic defects, but that the resulting magnetic sensitivity is essentially independent of both dose and energy. We then show that the magnetic sensitivity is significantly improved by high-temperature annealing at $\geq1100^\circ$C. Moreover, the spin properties are not significantly affected by oxygen annealing, apart from the spin relaxation time, which is dramatically decreased. Finally, the average NV depth is determined by nuclear magnetic resonance measurements, giving $\approx10$-17~nm at 4-6 keV implantation energy. This study sheds light on the optimal conditions to create dense layers of near-surface NV centres for high-sensitivity sensing and imaging applications.

cond-mat.mtrl-sci

Competition between electric field and magnetic field noise in the decoherence of a single spin in diamond

We analyze the impact of electric field and magnetic field fluctuations in the decoherence of the electronic spin associated with a single nitrogen-vacancy (NV) defect in diamond by engineering spin eigenstates protected either against magnetic noise or against electric noise. The competition between these noise sources is analyzed quantitatively by changing their relative strength through modifications of the environment. This study provides significant insights into the decoherence of the NV electronic spin, which is valuable for quantum metrology and sensing applications.

cond-mat.mes-hall

Isotopic identification of engineered nitrogen-vacancy spin qubits in ultrapure diamond

Nitrogen impurities help to stabilize the negatively-charged-state of NV$^-$ in diamond, whereas magnetic fluctuations from nitrogen spins lead to decoherence of NV$^-$ qubits. It is not known what donor concentration optimizes these conflicting requirements. Here we used 10-MeV $^{15}$N$^{3+}$ ion implantation to create NV$^-$ in ultrapure diamond. Optically detected magnetic resonance of single centers revealed a high creation yield of $40\pm3$% from $^{15}$N$^{3+}$ ions and an additional yield of $56\pm3$% from $^{14}$N impurities. High-temperature anneal was used to reduce residual defects, and charge stable NV$^-$, even in a dilute $^{14}$N impurity concentration of 0.06 ppb were created with long coherence times.

cond-mat.mes-hall

Indistinguishable photons from separated silicon-vacancy centers in diamond

We demonstrate that silicon-vacancy (SiV) centers in diamond can be used to efficiently generate coherent optical photons with excellent spectral properties. We show that these features are due to the inversion symmetry associated with SiV centers, and demonstrate generation of indistinguishable single photons from separate emitters in a Hong-Ou-Mandel (HOM) interference experiment.Prospects for realizing efficient quantum network nodes using SiV centers are discussed.

quant-ph

Multiple intrinsically identical single photon emitters in the solid-state

Emitters of indistinguishable single photons are crucial for the growing field of quantum technologies. To realize scalability and increase the complexity of quantum optics technologies, multiple independent yet identical single photon emitters are also required. However typical solid-state single photon sources are inherently dissimilar, necessitating the use of electrical feedback or optical cavities to improve spectral overlap between distinct emitters. Here, we demonstrate bright silicon-vacancy (SiV-) centres in low-strain bulk diamond which intrinsically show spectral overlap of up to 91% and near transform-limited excitation linewidths. Our results have impact upon the application of single photon sources for quantum optics and cryptography, and the production of next generation fluorophores for bio-imaging.

quant-ph

Direct observation of the leakage current in epitaxial diamond Schottky barrier devices by conductive-probe atomic force microscopy and Raman imaging

The origin of the high leakage current measured in several vertical-type diamond Schottky devices is conjointly investigated by conducting probe atomic force microscopy (CP-AFM) and confocal micro-Raman/Photoluminescence (PL) imaging analysis. Local areas characterized by a strong decrease of the local resistance (5-6 orders of magnitude drop) with respect to their close surrounding have been identified in several different regions of the sample surface. The same local areas, also referenced as electrical hot-spots, reveal a slightly constrained diamond lattice and three dominant Raman bands in the low-wavenumber region (590, 914 and 1040 cm-1). These latter bands are usually assigned to the vibrational modes involving boron impurities and its possible complexes that can electrically act as traps for charge carriers. Local current-voltage measurements performed at the hot-spots point out a trap-filled-limited (TFL) current as the main conduction mechanism favoring the leakage current in the Schottky devices.

cond-mat.mtrl-sci

Extending spin coherence times of diamond qubits by high temperature annealing

Spins of negatively charged nitrogen-vacancy (NV$^-$) defects in diamond are among the most promising candidates for solid-state qubits. The fabrication of quantum devices containing these spin-carrying defects requires position-controlled introduction of NV$^-$ defects having excellent properties such as spectral stability, long spin coherence time, and stable negative charge state. Nitrogen ion implantation and annealing enable the positioning of NV$^-$ spin qubits with high precision, but to date, the coherence times of qubits produced this way are short, presumably because of the presence of residual radiation damage. In the present work, we demonstrate that a high temperature annealing at 1000$^\circ$C allows 2 millisecond coherence times to be achieved at room temperature. These results were obtained for implantation-produced NV$^-$ defects in a high-purity, 99.99% $^{12}$C enriched single crystal chemical vapor deposited diamond. We discuss these remarkably long coherence times in the context of the thermal behavior of residual defect spins. [Published in Physical Review B {\bf{88}}, 075206 (2013)]

quant-ph

Detecting and polarizing nuclear spins with double resonance on a single electron spin

We report the detection and polarization of nuclear spins in diamond at room temperature by using a single nitrogen-vacancy (NV) center. We use Hartmann-Hahn double resonance to coherently enhance the signal from a single nuclear spin while decoupling from the noisy spin-bath, which otherwise limits the detection sensitivity. As a proof-of-principle we: (I) observe coherent oscillations between the NV center and a weakly coupled nuclear spin, (II) demonstrate nuclear bath cooling which prolongs the coherence time of the NV sensor by more than a factor of five. Our results provide a route to nanometer scale magnetic resonance imaging, and novel quantum information processing protocols.

quant-ph

Experimental implementation of assisted quantum adiabatic passage in a single spin

Quantum adiabatic passages can be greatly accelerated by a suitable control field, called a counter-diabatic field, which varies during the scan through resonance. Here, we implement this technique on the electron spin of a single nitrogen-vacancy center in diamond. We demonstrate two versions of this scheme. The first follows closely the procedure originally proposed by Demirplak and Rice (J. Phys. Chem. A 107, 9937 (2003)). In the second scheme, we use a control field whose amplitude is constant, but its phase varies with time. This version, which we call the rapid-scan approach, allows an even faster passage through resonance and therefore makes it applicable also for systems with shorter decoherence times.

quant-ph