SearcharxivSearch

arXiv subjects

T. Tsang

Publications and source records attributed to T. Tsang.

13 recordsLinked to original sources

European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment

PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/\mu}$ to 1 part in $10^4$, improving the current experimental result $R_{e/\mu}\,\text{(exp)} =1.2327(23)\times10^{-4}$ by a factor of 15. This precision on $R_{e/\mu}$ will match the theoretical accuracy of the SM prediction allowing for a test of LFU at an unprecedented level, probing non-SM explanations of LFU violation through sensitivity to quantum effects of new particles up to the PeV mass scale. Phase II and III will aim to improve the experimental precision of the branching ratio of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, currently at $1.036(6)\times10^{-8}$, by a factor of three and six, respectively. The improved measurements will be used to extract $V_{ud}$ in a theoretically pristine manner. The ultimate precision of $V_{ud}$ is expected to reach the 0.05\,\% level, allowing for a stringent test of CKM unitarity. The PIONEER experiment will also improve the experimental limits by an order of magnitude or more on a host of exotic decays that probe the effects of heavy neutrinos and dark sector physics. This input to the 2026 update of the European Strategy for Particle Physics Strategy describes the physics motivation and the conceptual design of the PIONEER experiment, and is prepared based on the PIONEER proposal submitted to and approved with high priority by the PSI program advisory committee (PAC). Using intense pion beams, and state-of-the-art instrumentation and computational resources, the PIONEER experiment is aiming to begin data taking by the end of this decade.

hep-ex

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.

physics.ins-det

Using spin alignment of inelastically-excited fast beams to make spin assignments: the spectroscopy of 13O as a test case

Excited states in 13O were investigated using inelastic scattering of an E/A=69.5-MeV 13O beam off of a 9Be target. The excited states were identified in the invariant-mass spectra of the decay products. Both single proton and sequential two-proton decays of the excited states were examined. For a number of the excited states, the protons were emitted with strong anisotropy where emissions transverse to the beam axis are favored. The measured proton-decay angular distributions were compared to predictions from distorted-wave born-approximation (DWBA) calculations of the spin alignment which was shown to be largely independent of the excitation mechanism. The deduced $^{13}$O level scheme is compared to ab initio no-core shell model with continuum (NCSMC) predictions. The lowest-energy excited states decay isotropically consistent with predictions of strong proton 1s1/2 structure. Above these states in the level scheme, we observed a number of higher-spin states not predicted within the model. Possibly these are associated with rotational bands built on deformed cluster configurations predicted by antisymmetrized molecular dynamics (AMD) calculations. The spin alignment mechanism is shown to be useful for making spin assignments and may have widespread use.

nucl-ex

Particle decays of levels in $^{11,12}$N and $^{12}$O investigated with the invariant-mass method

Particle-decaying states of the light nuclei $^{11,12}$N and $^{12}$O were studied using the invariant-mass method. The decay energies and intrinsic widths of a number of states were measured, and the momentum correlations of three-body decaying states were considered. A second 2$p$-decaying 2$^+$ state of $^{12}$O was observed for the first time, and a higher energy $^{12}$O state was observed in the 4$p$+2$α$ decay channel. This 4$p$+2$α$ channel also contains contributions from fission-like decay paths, including $^6$Be$_{g.s.}$+$^{6}$Be$_{g.s.}$. Analogs to these states in $^{12}$O were found in $^{12}$N in the 2$p$+$^{10}$B and 2$p$+$α$+$^6$Li channels. The momentum correlations for the prompt 2$p$ decay of $^{12}$O$_{g.s.}$ were found to be nearly identical to those of $^{16}$Ne$_{g.s.}$, and the correlations for the new 2$^+$ state were found to be consistent with sequential decay through excited states in $^{11}$N. The momentum correlations for the 2$^+_1$ state in $^{12}$O provide a new value for the $^{11}$N ground-state energy. The states in $^{12}$N/$^{12}$O that belong to the $A$=12 isobaric sextet do not deviate from the quadratic isobaric multiplet mass equation (IMME) form.

nucl-ex

Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode

Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are $1.97 \pm 0.04$ mm/$μ$s and $(-0.69\pm0.05)$\%/K for liquid xenon, and $1.42 \pm 0.03$ mm/$μ$s and $(+0.11\pm0.01)$\%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of $25.7 \pm 4.6$ cm$^2$/s and $149 \pm 23$ cm$^2$/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.

physics.ins-det

Characterization of the Hamamatsu VUV4 MPPCs for nEXO

In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233 \text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163 \text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse in the $1 \upmu\text{s}$ interval following the trigger pulse of $0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is $0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of $189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both values are well below the $24\text{ }\%$ saturation PDE advertised by Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBK-LF SiPMs for the final design of the nEXO detector.

astro-ph.IM

The FP420 R&D Project: Higgs and New Physics with forward protons at the LHC

We present the FP420 R&D project, which has been studying the key aspects of the development and installation of a silicon tracker and fast-timing detectors in the LHC tunnel at 420 m from the interaction points of the ATLAS and CMS experiments. These detectors would measure precisely very forward protons in conjunction with the corresponding central detectors as a means to study Standard Model (SM) physics, and to search for and characterise New Physics signals. This report includes a detailed description of the physics case for the detector and, in particular, for the measurement of Central Exclusive Production, pp --> p + phi + p, in which the outgoing protons remain intact and the central system phi may be a single particle such as a SM or MSSM Higgs boson. Other physics topics discussed are gamma-gamma and gamma-p interactions, and diffractive processes. The report includes a detailed study of the trigger strategy, acceptance, reconstruction efficiencies, and expected yields for a particular p p --> p H p measurement with Higgs boson decay in the b-bbar mode. The document also describes the detector acceptance as given by the LHC beam optics between the interaction points and the FP420 location, the machine backgrounds, the new proposed connection cryostat and the moving ("Hamburg") beam-pipe at 420 m, and the radio-frequency impact of the design on the LHC. The last part of the document is devoted to a description of the 3D silicon sensors and associated tracking performances, the design of two fast-timing detectors capable of accurate vertex reconstruction for background rejection at high-luminosities, and the detector alignment and calibration strategy.

hep-ex

A Single Shot, Sub-picosecond Beam Bunch Characterization with Electro-optic Techniques

In the past decade, the bunch lengths of electrons in accelerators have decreased dramatically to the range of a few picoseconds \cite{Uesaka94,Trotz97}. Measurement of the length as well as the longitudinal profile of these short bunches have been a topic of research in a number of institutions \cite{Uesaka97,Liu97,Hutchins00}. One of the techniques uses the electric field induced by the passage of electrons in the vicinity of a birefringent crystal to change its optical characteristics. Well-established electro-optic techniques can then be used to measure the temporal characteristics of the electron bunch. In this paper we present a novel, non-invasive, single-shot approach to improve the resolution to tens of femtoseconds so that sub-millimeter bunch length can be measured.

physics.acc-ph

ElectroOptical measurements of ultrashort 45 MeV electron beam bunch

We have made an observation of 45 MeV electron beam bunches using the nondestructive electro-optical (EO) technique. The amplitude of the EO modulation was found to increase linearly with electron beam charge and decrease inversely with the optical beam path distance from the electron beam. The risetime of the signal was bandwidth limited by our detection system to \~70ps. An EO signal due to ionization caused by the electrons traversing the EO crystal was also observed. The EO technique may be ideal for the measurement of bunch structure with femtosecond resolution of relativistic charged particle beam bunches.

hep-ex

Electrooptical Measurements of Ultrashort 45 MeV Electron Beam Bunches

We have measured the temporal duration of 45 MeV picosecond electron beam bunches using a noninvasive electro-optical (EO) technique. The amplitude of the EO modulation was found to increase linearly with electron beam charge and decrease inversely with distance from the electron beam. The risetime of the temporal signal was limited by our detection system to ~70ps. The EO signal due to ionization caused by the electrons traversing the EO crystal was also observed. It has a distinctively long decay time constant and signal polarity opposite to that due to the field induced by the electron beam. The electro-optical technique may be ideal for the measurement of bunch length of femtosecond, relativistic, high energy, charged, particle beams.

hep-ex

First Electrooptical Detection of Charged Particles

We have made the first observation of a charged particle beam by means of its electro-optical effect on the polarization of laser light in a birefringent crystal. The modulation of the laser light during the passage of a pulsed electron beam was observed using a fast photodiode and a digital oscilloscope. The fastest rise time measured in a single shot, 120 ps, was limited by the bandwidth of the oscilloscope and the associated electronics. This technology holds promise for detectors of greatly improved spatial and temporal resolution for single relativistic charged particles as well as particle beams.

hep-ex

Electrooptical Detection of Charged Particles

We have made the first observation of a charged particle beam by means of its electro-optical effect on the polarization of laser light in a LiNbO3 crystal. The modulation of the laser light during the passage of a pulsed electron beam was observed using a fast photodiode and a digital oscilloscope. The fastest rise time measured, 120 ps, was obtained in the single shot mode and was limited by the bandwidth of the oscilloscope and the associated electronics. This technology holds promise for detectors of greatly improved spatial and temporal resolution for single relativistic charged particles as well as particle beams.

hep-ex

Electrooptical Detection of Charged Particle Beams

We have made the first observation of a charged particle beam by means of its electro-optical effect on the propagation of laser light in a birefringent crystal at the Brookhaven National Laboratory Accelerator Test Facility. Polarized infrared light was coupled to a LiNbO3 crystal through a polarization maintaining fiber of 4 micron diameter. An electron beam in 10ps bunches of 1mm diameter was scanned across the crystal. The modulation of the laser light during passage of the electron beam was observed using a photodiode with 45GHz bandwidth. The fastest rise time measured, 120ps, was made in the single shot mode and was limited by the bandwidth of the oscilloscope and the associated electronics. Both polarization dependent and polarization independent effects were observed. This technology holds promise of greatly improved spatial and temporal resolution of charged particle beams.

hep-ex