SearcharxivSearch

arXiv subjects

T. Uchiyama

Publications and source records attributed to T. Uchiyama.

5 recordsLinked to original sources

A Study of Cooling Time Reduction of Interferometric Cryogenic Gravitational Wave Detectors Using a High-Emissivity Coating

In interferometric cryogenic gravitational wave detectors, there are plans to cool mirrors and their suspension systems (payloads) in order to reduce thermal noise, that is, one of the fundamental noise sources. Because of the large payload masses (several hundred kg in total) and their thermal isolation, a cooling time of several months is required. Our calculation shows that a high-emissivity coating (e.g. a diamond-like carbon (DLC) coating) can reduce the cooling time effectively by enhancing radiation heat transfer. Here, we have experimentally verified the effect of the DLC coating on the reduction of the cooling time.

gr-qc

Direct observation of quantized interlayer vortex flow and vortex pinning distribution in high-Tc La_(1.87)Sr_(0.13)CuO_4 single crystals

A scanning superconducting quantum interference device (SQUID) microscope (SSM) is used to study the magnetic imaging of dynamic motion of quantized interlayer vortices induced by the Lorentz force in anisotropic high-Tc La_(1.87)Sr_(0.13)CuO_4 single crystals. It is found that 3 modes of flux motion switch depending on the transport current. By increasing the current a transition from the creep-like behavior of vortices to a steady flow of vortices was observed. Even higher current induced a continuous expansion of vortex-flow area indicating an inhomogeneous distribution of various pinning centers.

cond-mat.supr-con

Force measurements of a superconducting-film actuator for a cryogenic interferometric gravitational-wave detector

We measured forces applied by an actuator with a YBCO film at near 77 K for the Large-scale Cryogenic Gravitational-wave Telescope (LCGT) project. An actuator consisting of both a YBCO film of 1.6 micrometers thickness and 0.81 square centimeters area and a solenoid coil exerted a force of up to 0.2 mN on a test mass. The presented actuator system can be used to displace the mirror of LCGT for fringe lock of the interferometer.

gr-qc

Partial and macroscopic phase coherences in underdoped Bi${}_{2}$Sr${}_{2}$CaCu${}_{2}$O${}_{8+δ}$ thin film

A combined study with use of time-domain pump-probe spectroscopy and time-domain terahertz transmission spectroscopy have been carried out on an underdoped Bi$_2$Sr$_2$CaCu$_2$O$_{8+δ}$ thin film. It was observed that the low energy multi-excitation states were decomposed into superconducting gap and pseudogap. The pseudogap locally opens below $T^*{\simeq}210$ K simultaneously with the appearance of the high-frequency partial pairs around 1.3 THz. With decreasing temperature, the number of the local domains with the partial phase coherence increased and saturated near 100 K, and the macroscopic superconductivity appeared below 76 K through the superconductivity fluctuation state below 100 K. These experimental results indicate that the pseudogap makes an important role for realization of the superconductivity as a precursor to switch from the partial to the macroscopic phase coherence.

cond-mat.mtrl-sci

Mechanical quality factor of a sapphire fiber at cryogenic temperatures

A mechanical quality factor of $1.1 \times 10^{7}$ was obtained for the 199 Hz bending vibrational mode in a monocrystalline sapphire fiber at 6 K. Consequently, we confirm that pendulum thermal noise of cryogenic mirrors used for gravitational wave detectors can be reduced by the sapphire fiber suspension.

gr-qc