Bi-planar magnetic stabilisation coils for an inertial sensor based on atom interferometry

Inertial sensors that measure the acceleration of ultracold atoms promise unrivalled accuracy compared to classical equivalents. However, atomic systems are sensitive to various perturbations, including magnetic fields, which can introduce measurement inaccuracies. To address this challenge, we have designed, manufactured, and validated a magnetic field stabilisation system for a quantum sensor based on atom interferometry. We solve for the magnetic field generated by surface currents in-between a pair of rectangular coils and approximate the surface current using discrete wires. The wires are wound by-hand onto machined panels which are retrofitted onto the existing mounting structure of the sensor without interfering with any experimental components. Along the central $60$ mm of the $y$-axis, which aligns with the trajectory of the atoms during interferometry, the coils are measured to generate an independent uniform axial magnetic field with a strength of $B_z=\left(22.81\pm0.01\right)$ $μ$T/A [$\mathrm{mean}\pm2σ\mathrm{std. error}$] and an independent linear axial field gradient of strength $\mathrm{d}B_z/\mathrm{d}y=\left(10.6\pm0.1\right)$ $μ$T/Am. The uniform $B_z$ field is measured to deviate by a maximum value of $1.3$% in the same region, which is a factor of three times more uniform than the previously-used on-sensor rectangular $B_z$ compensation set.

physics.atom-ph

Benchtop magnetic shielding for benchmarking atomic magnetometers

Here, a benchtop hybrid magnetic shield containing four mumetal cylinders and nine internal flexible printed circuit boards is designed, constructed, tested, and operated. The shield is designed specifically as a test-bed for building and operating ultra-sensitive quantum magnetometers. The geometry and spacing of the mumetal cylinders are optimized to maximize shielding efficiency while maintaining Johnson noise $<15$ fT/$\sqrt{}$Hz. Experimental measurements at the shield's center show passive shielding efficiency of $\left(1.0\pm0.1\right){\times}10^6$ for a $0.2$ Hz oscillating field applied along the shield's axis. The nine flexible printed circuit boards generate three uniform fields, which all deviate from perfect uniformity by ${\leq}0.5$% along $50$% of the inner shield axis, and five linear field gradients and one second-order gradient, which all deviate by ${\leq}4$% from perfect linearity and curvature, respectively, over measured target regions. Together, the target field amplitudes are adjusted to minimize the remnant static field along $40$% of the inner shield axis, as mapped using an atomic magnetometer. In this region, the active null reduces the norm of the magnitudes of the three uniform fields and six gradients by factors of $19.5$ and $19.8$, respectively, thereby reducing the total static field from $1.68$ nT to $0.23$ nT.

physics.ins-det