Searcharxiv⌕ Search

arXiv subjects

T. Yoshioka

Publications and source records attributed to T. Yoshioka.

At least 37 records · Page 2Linked to original sources

Measurement of $γ$ rays from $^6$LiF tile as an inner wall of a neutron-decay detector

A neutron lifetime measurement conducted at the Japan Proton Accelerator Research Complex (J-PARC) is counting the number of electrons from neutron decays with a time projection chamber (TPC). The $γ$ rays produced in the TPC cause irreducible background events. To achieve the precise measurement, the inner walls of the TPC consist of $^6$Li-enriched lithium-fluoride ($^6$LiF) tiles to suppress the amount of $γ$ rays. In order to estimate the amount of $γ$ rays from the $^{6}{\rm LiF}$ tile, prompt gamma ray analysis (PGA) measurements were performed using germanium detectors. We reconstructed the measured $γ$-ray energy spectrum using a Monte Carlo simulation with the stripping method. Comparing the measured spectrum with a simulated one, the number of $γ$ rays emitted from the$^{6}{\rm LiF}$ tile was $(2.3^{+0.7}_{-0.3}) \times 10^{-4}$ per incident neutron. This is $1.4^{+0.5}_{-0.2}$ times the value assumed for a mole fraction of the $^{6}{\rm LiF}$ tile. We concluded that the amount of $γ$ rays produced from the $^{6}{\rm LiF}$ tile is not more twice the originally assumed value.

physics.ins-det↗

Performance evaluation of a silicon strip detector for positrons/electrons from a pulsed a muon beam

A high-intensity pulsed muon beam is becoming available at the at the Japan Proton Accelerator Research Complex (J-PARC). Many experiments to study fundamental physics using this high-intensity muon beam are proposed. An experiment to measure the muon magnetic moment anomaly ($g-2$) and the muon electric dipole moment (EDM) is one of these experiments and it requires a tracking detector for positrons from muon decay. Fine segmentation is required in a detector to tolerate the high rate of positrons. The time resolution is required to be much better than the muon anomalous spin precession period while a buffer depth of a front-end electronics needs to be much longer than the accelerated muon lifetime. Requirements of this detector also meet requirements of a measurement of the muonium hyperfine structure interval at the J-PARC and another experiment to measure the proton charge radius at Tohoku University. We have developed a single-sided silicon strip sensor with a 190 $μ$m pitch, a front-end electronics with a sampling rate of 200 MHz and a buffer memory depth of 8192, and a data acquisition system based on DAQ-Middleware for the J-PARC muon $g-2$/EDM experiment. We have fabricated detector modules consisting of this sensor and the front-end electronics. Performance of fabricated detector modules was evaluated at a laboratory and a beam test using the positron beam at Tohoku University. The detector is confirmed to satisfy all requirements of the experiments except for the time walk, which will be solved by the next version of a front-end electronics.

physics.ins-det↗

Particle Identification Using Boosted Decision Trees in the Semi-Digital Hadronic Calorimeter Prototype

The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) prototype using Glass Resistive Plate Chambers as a sensitive medium is the first technological prototype of a family of high-granularity calorimeters developed by the CALICE collaboration to equip the experiments of future leptonic colliders. It was exposed to beams of hadrons, electrons and muons several times in the CERN PS and SPS beamlines between 2012 and 2018. We present here a new method of particle identification within the SDHCAL using the Boosted Decision Trees (BDT) method applied to the data collected in 2015. The performance of the method is tested first with Geant4-based simulated events and then on the data collected by the SDHCAL in the energy range between 10 and 80~GeV with 10~GeV energy steps. The BDT method is then used to reject the electrons and muons that contaminate the SPS hadron beams.

physics.ins-det↗

Study of Position Sensitive Silicon Detector (PSD) for SiW-ECAL at ILC

We are developing position sensitive silicon detectors (PSDs) which have an electrode at each of four corners so that incident position of a charged particle can be obtained with signal from the electrodes. It is expected that the position resolution of the electromagnetic calorimeter (ECAL) of the ILD detector will be improved by introducing PSDs to detection layers. We have been developing the PSDs for several years. In the previous production we found that the charge separation is not optimally done due to the readout impedance. To solve the issue, we produced new PSDs with higher surface resistance with an additional resistive layer on the surface. We also implemented several techniques to decrease position distortion and increase signal-to-noise ratio which are essential for the optimal position resolution. The measurements on the prototype sensors are ongoing, including radiation source measurement and laser measurement using an ASIC for silicon pad detectors.

physics.ins-det↗

Study of silicon sensors for precise timing measurement

Silicon sensors with high time resolution can help particle identification in the International Linear Collider (ILC). We are studying Low Gain Avalanche Diodes (LGADs) as a high timing resolution sensor. As a step to develop LGADs, we are now focusing to characterize Avalanche Photo Diode (APD)s, because the APDs has the same multiplication structure as LGADs. We studied the characteristics of APDs with particles from radioisotopes.

physics.ins-det↗

Beam test performance of the highly granular SiW-ECAL technological prototype for the ILC

The technological prototype of the CALICE highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) was tested in a beam at DESY in 2017. The setup comprised seven layers of silicon sensors. Each layer comprised four sensors, with each sensor containing an array of 256 $5.5\times5.5$ mm$^2$ silicon PIN diodes. The four sensors covered a total area of $18\times18$ cm$^2$, and comprised a total of 1024 channels. The readout was split into a trigger line and a charge signal line. Key performance results for signal over noise for the two output lines are presented, together with a study of the uniformity of the detector response. Measurements of the response to electrons for the tungsten loaded version of the detector are also presented.

physics.ins-det↗

Characterisation of different stages of hadronic showers using the CALICE Si-W ECAL physics prototype

A detailed investigation of hadronic interactions is performed using $π^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008. The region in which the $π^-$-mesons interact with the detector material and the produced secondary particles are characterised using a novel track-finding algorithm that reconstructs tracks within hadronic showers in a calorimeter in the absence of a magnetic field. The principle of carrying out detector monitoring and calibration using secondary tracks is also demonstrated.

physics.ins-det↗

Improved determination of thermal cross section of 14N(n,p)14C for the neutron lifetime measurement

In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of ${}^{3}{\rm He}$ in the mixture. In order to improve the accuracy of the number density of the ${}^{3}{\rm He}$ nuclei, we suggested to use the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction as a reference because this reaction involves similar kinetic energy as the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction and a smaller reaction cross section to introduce reasonable large partial pressure. The uncertainty of the recommended value of the cross section, however, is not satisfied with our requirement. In this paper, we report the most accurate experimental value of the cross section of the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction at a neutron velocity of 2200 m/s, measured relative to the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction. The result was 1.868 $\pm$ 0.003 (stat.) $\pm$ 0.006 (sys.) b. Additionally, the cross section of the ${}^{17}{\rm O}({\rm n},{\rm α}){}^{14}{\rm C}$ reaction at the neutron velocity is also redetermined as 249 $\pm$ 6 mb.

nucl-ex↗

Commissioning of the highly granular SiW-ECAL technological prototype

In this article we describe the commissioning and a first analysis of the the beam test performance of a small prototype of a highly granular silicon tungsten calorimeter. The prototype features detector elements with a channel number similar to that envisaged for e.g. the ILD Detector of the International Linear Collider (ILC). The analysis demonstrates the capability of the detector to record signals as low as 0.5 MIP. Further, no loss of performance has been observed when operating the detector in a high magnetic field.

physics.ins-det↗

A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment

This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon $g-2$ experiments with unprecedented quality of the storage magnetic field. Additional significant differences from the present experimental method include a factor of 1,000 smaller transverse emittance of the muon beam (reaccelerated thermal muon beam), its efficient vertical injection into the solenoid, and tracking each decay positron from muon decay to obtain its momentum vector. The precision goal for $a_μ$ is statistical uncertainty of 450 part per billion (ppb), similar to the present experimental uncertainty, and a systematic uncertainty less than 70 ppb. The goal for EDM is a sensitivity of $1.5\times 10^{-21}~e\cdot\mbox{cm}$.

physics.ins-det↗

Quark charge identification for $e^{+}e^{-}$ to $q\bar{q}$ study

The process $e^{+}e^{-} \to q\bar{q}$ plays an important role in electroweak precision measurements. We are studying this process with ILD full simulation. The key for the reconstruction of the quark pair final states is quark charge identification (ID). We report the progress of charge ID study in detail. In particular, we investigate the performance of the charge ID for each decay mode of the heavy hadrons to know the possibilities of improvements of the charge ID.

physics.ins-det↗

Analysis of Testbeam Data of the Highly Granular RPC-Steel CALICE Digital Hadron Calorimeter and Validation of Geant4 Monte Carlo Models

We present a study of the response of the highly granular Digital Hadronic Calorimeter with steel absorbers, the Fe-DHCAL, to positrons, muons, and pions with momenta ranging from 2 to 60 GeV/c. Developed in the context of the CALICE collaboration, this hadron calorimeter utilises Resistive Plate Chambers as active media, interspersed with steel absorber plates. With a transverse granularity of $1\,\times\,1\,$cm$^{2}$ and a longitudinal segmentation of 38 layers, the calorimeter counted 350,208 readout channels, each read out with single-bit resolution (digital readout). The data were recorded in the Fermilab test beam in 2010-11. The analysis includes measurements of the calorimeter response and the energy resolution to positrons and muons, as well as detailed studies of various shower shape quantities. The results are compared to simulations based on Geant4, which utilise different electromagnetic and hadronic physics lists.

physics.ins-det↗

Hadronic Energy Resolution of a Combined High Granularity Scintillator Calorimeter System

This paper presents results obtained with the combined CALICE Scintillator Electromagnetic Calorimeter, Analogue Hadronic Calorimeter and Tail Catcher & Muon Tracker, three high granularity scintillator-SiPM calorimeter prototypes. The response of the system to pions with momenta between 4 GeV/c and 32 GeV/c is analysed, including the energy response, resolution, and longitudinal shower profiles. The results of a software compensation technique based on weighting according to hit energy are compared to those of a standard linear energy reconstruction. The results are compared to predictions of the GEANT4 physics lists QGSP_BERT_HP and FTFP_BERT_HP.

physics.ins-det↗

Magnetic properties in the metallic magnets with large anisotropy

We study low temperature properties in the metallic magnets, considering the itinerant electron mediated ferromagnetism. Applying the Monte Carlo simulations to the extended double exchange model, we discuss reorientation phase transition and anisotropy field for the metallic magnets.

cond-mat.str-el↗

Construction and Response of a Highly Granular Scintillator-based Electromagnetic Calorimeter

A highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future lepton collider experiments. A prototype of 21.5 $X_0$ depth and $180 \times 180 $mm$^2$ transverse dimensions was constructed, consisting of 2160 individually read out $10 \times 45 \times 3$ mm$^3$ scintillator strips. This prototype was tested using electrons of 2--32 GeV at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1\%, and the intrinsic energy resolution was determined to be $(12.5 \pm 0.1 (\mathrm{stat.}) \pm0.4 (\mathrm{syst.}))\%/\sqrt{E[\mathrm{GeV}]}\oplus (1.2 \pm 0.1(\mathrm{stat.})^{+0.6}_{-0.7}(\mathrm{syst.}))\%$, where the uncertainties correspond to statistical and systematic sources, respectively.

physics.ins-det↗

Performance study of SKIROC2/A ASIC for ILD Si-W ECAL

The ILD Si-W ECAL is a sampling calorimeter with tungsten absorber and highly segmented silicon layers for the International Large Detector (ILD), one of the two detector concepts for the International Linear Collider. SKIROC2 is an ASIC for the ILD Si-WECAL. To investigate the issues found in prototype detectors, we prepared dedicated ASIC evaluation boards with either BGA sockets or directly soldered SKIROC2. We report a performance study with the evaluation boards, including signal-to-noise ratio and TDC performance with comparing SKIROC2 and an updated version, SKIROC2A.

physics.ins-det↗

Performance study of SKIROC2 and SKIROC2A with BGA testboard

SKIROC2 is an ASIC to readout the silicon pad detectors for the electromagnetic calorimeter in the International Linear Collider. Characteristics of SKIROC2 and the new version of SKIROC2A, packaged with BGA, are measured with testboards and charge injection. The results on the signal-to-noise ratio of both trigger and ADC output, threshold tuning capability and timing resolution are presented.

physics.ins-det↗