SearcharxivSearch

arXiv subjects

T. Zerguerras

Publications and source records attributed to T. Zerguerras.

2 recordsLinked to original sources

Feasibility studies of the time-like proton electromagnetic form factor measurements with PANDA at FAIR

The possibility of measuring the proton electromagnetic form factors in the time-like region at FAIR with the \PANDA detector is discussed. Detailed simulations on signal efficiency for the annihilation of $\bar p +p $ into a lepton pair as well as for the most important background channels have been performed. It is shown that precision measurements of the differential cross section of the reaction $\bar p +p \to e^++ e^-$ can be obtained in a wide angular and kinematical range. The individual determination of the moduli of the electric and magnetic proton form factors will be possible up to a value of momentum transfer squared of $q^2\simeq 14$ (GeV/c)$^2$. The total $\bar p +p\to e^++e^-$ cross section will be measured up to $q^2\simeq 28$ (GeV/c)$^2$. The results obtained from simulated events are compared to the existing data. Sensitivity to the two photons exchange mechanism is also investigated.

nucl-ex

Single electron response and energy resolution of a Micromegas detector

Micro-Pattern Gaseous Detectors (MPGDs) such as Micromegas or GEM are used in particle physics experiments for their capabilities in particle tracking at high rates. Their excellent position resolutions are well known but their energy characteristics have been less studied. The energy resolution is mainly affected by the ionisation processes and detector gain fluctuations. This paper presents a method to separetely measure those two contributions to the energy resolution of a Micromegas detector. The method relies on the injection of a controlled number of electrons. The Micromegas has a 1.6-mm drift zone and a 160-$μ$m amplification gap. It is operated in Ne 95%-iC$\mathrm{_4}$H$\mathrm{_{10}}$ 5% at atmospheric pressure. The electrons are generated by non-linear photoelectric emission issued from the photons of a pulsed 337-nm wavelength laser coupled to a focusing system. The single electron response has been measured at different gains (3.7 10$\mathrm{^4}$, 5.0 10$\mathrm{^4}$ and 7.0 10$\mathrm{^4}$) and is fitted with a good agreement by a Polya distribution. From those fits, a relative gain variance of 0.31$\pm$0.02 is deduced. The setup has also been characterised at several voltages by fitting the energy resolution measured as a function of the number of primary electrons, ranging from 5 up to 210. A maximum value of the Fano factor (0.37) has been estimated for a 5.9 keV X-rays interacting in the Ne 95%-iC$\mathrm{_4}$H$\mathrm{_{10}}$ 5% gas mixture.

physics.ins-det