SearcharxivSearch

arXiv subjects

Takafumi Kojima

Publications and source records attributed to Takafumi Kojima.

10 recordsLinked to original sources

A Wideband Millimeter-wave Receiver at 210-350 GHz for LMT-FINER

The Far-Infrared Nebular Emission Receiver (FINER) project is developing two wideband dual-polarization sideband-separating receivers covering 120-210 GHz and 210-350 GHz to efficiently identify high-redshift galaxy candidates in the early universe. Based on high-critical-current-density superconductor-insulator-superconductor mixer technology originally developed for the ALMA wideband sensitivity upgrade, the FINER receivers are designed to provide an intermediate-frequency bandwidth of 3-21 GHz per sideband and per polarization, approximately five times wider than the current ALMA specifications. After installation on the Large Millimeter Telescope, these receivers are expected to offer highly efficient spectral-scanning capability among (sub)millimeterwave facilities in the northern-hemisphere. This paper reports the initial laboratory characterization of the 210-350 GHz receiver. The measured single sideband receiver noise temperature is approximately 100 K over most of the radio-frequency band. Digital sideband separation was also demonstrated using a wideband spectrometer array (DRS4), achieving an image rejection ratio of around 20 dB in the initial tests. These results represent an important step toward the realization of a wideband spectral-scanning receiver system for FINER.

astro-ph.IM

FINER: development of the wideband millimeter-wave receiver system and preparations for first light on the Large Millimeter Telescope

The recent discovery of an excess of luminous galaxies in the early Universe necessitates sensitive and wideband millimeter spectroscopy to understand their rapid growth. To address this, we present the development of the Far-Infrared Nebular Emission Receiver (FINER) for the Large Millimeter Telescope (LMT). The FINER frontend comprises two receivers covering 120-350 GHz (corresponding to ALMA Bands 4+5 and 6+7). The warm optics are designed to enable simultaneous two-band observations. Combined with the 10.24-GHz-wide digital spectrometer array, the system aims to deliver an instantaneous bandwidth approximately five times wider than current ALMA capabilities. We report that the 210-350 GHz receiver has already achieved commissioning-level performance, with sideband rejection further enhanced by the digital sideband separation technique. With installation expected in 2026, we discuss parallel preparations, including integrated testing and commissioning plans for first-look targets.

astro-ph.IM

Observations of DNC and DCO$^+$ toward the $\int$-shaped Filament and Starless Cores in the Orion Molecular Clouds

Although the deuterium fraction is known to be a powerful evolutionary tracer, its variation within individual molecular cloud cores is still poorly understood. The northern $\int$-shaped filament and 20 individual starless cores in the Orion A and B clouds were mapped in the deuterated molecules of DNC and DCO$^+$ with the Receiver 7BEE installed on the Nobeyama 45~m radio telescope. In a ~ 5' X 30' map of the northern $\int$-shaped filament in the Orion A cloud, the DNC emission is detected over the filament, whereas the DCO$^+$ emission is localized toward OMC-3, the northernmost region of the filament. The difference in distribution between DNC and DCO$^+$ can be attributed to that between N- and C-bearing molecules as previously suggested by Tatematsu et al. High DNC/HN$^{13}$C column density ratios were observed in OMC-2 and OMC-3, and low ratios in OMC-1. It seems that OMC-2 and OMC-3 still contain molecular gas close to the onset of star formation. In 3' X 3' maps of the individual starless cores in Orion, the column density ratios of DNC/HN$^{13}$C and DCO$^+$/H$^{13}$CO$^+$ are found to be rather constant locally within each core, although the core-to-core variation is not small. Similar timescales of deuterization, depletion, and dynamical evolution might explain the locally constant ratio.

astro-ph.GA

Fabrication and characterization of Nb/Al-AlN /Nb superconducting tunnel junctions

We report a Nb/Al-AlN /Nb superconducting tunnel junction process in which the AlN barrier is formed by plasma nitridation using a compact microwave electron-cyclotron-resonance (ECR) nitrogen plasma source integrated into a standard sputter cluster. This enables growth of uniform tunnel barriers across a broad range of specific resistances, with $R_n A$ down to $\approx 3,Ω,μ\mathrm{m}^2$. Junctions maintain excellent quality, exhibiting $R_j/R_n \ge 25$ at the highest barrier transparencies. We characterize resistivity, specific capacitance, and the evolution of junction parameters under room-temperature aging and thermal annealing. A consistent calibration of the junction specific capacitance $C_s$ versus $R_n A$ is established and independently validated by the performance of demonstrator SIS mixers designed using the extracted $C_s$.

cond-mat.supr-con

FINER: Far-Infrared Nebular Emission Receiver for the Large Millimeter Telescope

Unveiling the emergence and prevalence of massive/bright galaxies during the epoch of reionization and beyond, within the first 600 million years of the Universe, stands as a pivotal pursuit in astronomy. Remarkable progress has been made by JWST in identifying an immense population of bright galaxies, which hints at exceptionally efficient galaxy assembly processes. However, the underlying physical mechanisms propelling their rapid growth remain unclear. With this in mind, millimeter and submillimeter-wave spectroscopic observations of redshifted far-infrared spectral lines, particularly the [O III] 88 micron and [C II] 158 micron lines, offers a crucial pathway to address this fundamental query. To this end, we develop a dual-polarization sideband-separating superconductor-insulator-superconductor (SIS) mixer receiver, FINER, for the Large Millimeter Telescope (LMT) situated in Mexico. Harnessing advancements from ALMA's wideband sensitivity upgrade (WSU) technology, FINER covers radio frequencies spanning 120-360 GHz, delivering an instantaneous intermediate frequency (IF) of 3-21 GHz per sideband per polarization, which is followed by a set of 10.24 GHz-wide digital spectrometers. At 40% of ALMA's light-collecting area, the LMT's similar atmospheric transmittance and FINER's 5 times wider bandwidth compared to ALMA culminate in an unparalleled spectral scanning capability in the northern hemisphere, paving the way for finer spectral-resolution detection of distant galaxies.

astro-ph.IM

Development Status of Wideband Millimeter-Wave Receivers for LMT-FINER

Spectroscopic observations of the far-infrared [O III] and [C II] lines present a pathway to explore the mechanisms of the emergence of massive galaxies in the epoch of reionization and beyond, which is one of the most fundamental questions in astronomy. To address this question, the Far-Infrared Nebular Emission Receiver (FINER) project is developing two wideband dual-polarization sideband-separating heterodyne receivers at 120--210 GHz and 210--360 GHz for the Large Millimeter Telescope (LMT) in Mexico. Compared with Atacama Large Millimeter/submillimeter Array (ALMA), LMT provides 40% of ALMA's light-collecting area and a similar atmospheric transmittance, but FINER plans to have an instantaneous intermediate frequency (IF) of 3--21 GHz per sideband per polarization which is five times wider than current ALMA's bandwidth. Therefore, FINER is going to offer cutting-edge spectral scanning capability in the next several years. The project is currently in an active development phase. In this proceeding, the latest development status for FINER, including the optics, wideband waveguide components as well as low-noise superconductor-insulator-superconductor (SIS) mixers is reported.

astro-ph.IM

Development of a new wideband heterodyne receiver system for the Osaka 1.85-m mm-submm telescope -- Corrugated horn & Optics covering 210-375 GHz band

The corrugated horn is a high performance feed often used in radio telescopes. There has been a growing demand for wideband optics and corrugated horns in millimeter and submillimeter-wave receivers. It improves the observation efficiency and allows us to observe important emission lines such as CO in multiple excited states simultaneously. However, in the millimeter/submillimeter band, it has been challenging to create a conical corrugated horn with a fractional bandwidth of ~60% because the wavelength is very short, making it difficult to make narrow corrugations. In this study, we designed a conical corrugated horn with good return loss, low cross-polarization, and symmetric beam pattern in the 210-375GHz band (56% fractional bandwidth) by optimizing the dimensions of the corrugations. The corrugated horn was installed on the Osaka 1.85-m mm-submm telescope with the matched frequency-independent optics, and simultaneous observations of 12CO, 13CO, and C18O (J = 2-1, 3-2) were successfully made. In this paper, we describe the new design of the corrugated horn and report the performance evaluation results including the optics.

astro-ph.IM

Development of a new wideband heterodyne receiver system for the Osaka 1.85-m mm-submm telescope -- Receiver development & the first light of simultaneous observation in 230GHz and 345GHz bands with an SIS-mixer with 4-21GHz IF output

We have developed a wideband receiver system for simultaneous observations in CO lines of J = 2-1 and J = 3-2 transitions using the Osaka 1.85-m mm-submm telescope. As a frequency separation system, we developed multiplexers that connect three types of diplexers, each consisting of branch-line couplers and high-pass filters. The radio frequency (RF) signal is eventually distributed into four frequency bands, each of which is fed to a superconductor-insulator-superconductor (SIS) mixer. The RF signal from the horn is divided into two frequency bands by a wideband diplexer with a fractional bandwidth of 56%, and then each frequency band is further divided into two bands by each diplexer. The developed multiplexers were designed, fabricated, and characterized using a vector network analyzer. The measurement results showed good agreement with the simulation. The receiver noise temperature was measured by connecting the SIS-mixers, one of which has a wideband 4-21GHz intermediate frequency (IF) output. The receiver noise temperatures were measured to be ~70K in the 220GHz band, ~100K in the 230GHz band, 110-175K in the 330GHz band, and 150-250K in the 345GHz band. This receiver system has been installed on the 1.85-m telescope at the Nobeyama Radio Observatory. We succeeded in the simultaneous observations of six CO isotopologue lines with the transitions of J = 2-1 and J = 3-2 toward the Orion KL as well as the on-the-fly (OTF) mappings toward the Orion KL and W 51.

astro-ph.IM

Waveguide-Type Multiplexer for Multiline Observation of Atmospheric Molecules using Millimeter-Wave Spectroradiometer

In order to better understand the variation mechanism of ozone abundance in the middle atmosphere, the simultaneous monitoring of ozone and other minor molecular species, which are related to ozone depletion, is the most fundamental and critical method. A waveguide-type multiplexer was developed for the expansion of the observation frequency range of a millimeter-wave spectroradiometer, for the simultaneous observation of multiple molecular spectral lines. The proposed multiplexer contains a cascaded four-stage sideband-separating filter circuit. The waveguide circuit was designed based on electromagnetic analysis, and the pass frequency bands of Stages 1-4 were 243-251 GHz, 227-235 GHz, 197-205 GHz, and 181-189 GHz. The insertion and return losses of the multiplexer were measured using vector network analyzers, each observation band was well-defined, and the bandwidths were appropriately specified. Moreover, the receiver noise temperature and the image rejection ratio (IRR) using the superconducting mixer at 4 K were measured. As a result, the increase in receiver noise due to the multiplexer compared with that of only the mixer can be attributed to the transmission loss of the waveguide circuit in the multiplexer. The IRRs were higher than 25 dB at the center of each observation band. This indicates that a high and stable IRR performance can be achieved by the waveguide-type multiplexer for the separation of sideband signals.

astro-ph.IM

Experimental Study of a Planar-integrated Dual-Polarization Balanced SIS Mixer

A dual-polarization balanced superconductor-insulator-superconductor mixer operating at 2 mm wavelength is realized in form of a monolithic planar integrated circuit. Planar orthomode transducers and LO couplers are enabled by using silicon membranes that are locally formed on the silicon-on-insulator substrate. The performance of the balanced mixer is experimentally investigated. Over the entire RF band (125-163 GHz), the balanced mixer shows an LO noise rejection ratio about 15 dB, an overall receiver noise about 40 K, and a cross-polarization <-20 dB. The demonstrated compactness and the performance of the integrated circuit indicate that this approach is feasible in developing heterodyne focal plane arrays.

astro-ph.IM