Searcharxiv⌕ Search

arXiv subjects

Takao Kitaguchi

Publications and source records attributed to Takao Kitaguchi.

At least 109 records · Page 6Linked to original sources

Hitomi constraints on the 3.5 keV line in the Perseus galaxy cluster

High-resolution X-ray spectroscopy with Hitomi was expected to resolve the origin of the faint unidentified E=3.5 keV emission line reported in several low-resolution studies of various massive systems, such as galaxies and clusters, including the Perseus cluster. We have analyzed the Hitomi first-light observation of the Perseus cluster. The emission line expected for Perseus based on the XMM-Newton signal from the large cluster sample under the dark matter decay scenario is too faint to be detectable in the Hitomi data. However, the previously reported 3.5 keV flux from Perseus was anomalously high compared to the sample-based prediction. We find no unidentified line at the reported high flux level. Taking into account the XMM measurement uncertainties for this region, the inconsistency with Hitomi is at a 99% significance for a broad dark-matter line and at 99.7% for a narrow line from the gas. We do not find anomalously high fluxes of the nearby faint K line or the Ar satellite line that were proposed as explanations for the earlier 3.5 keV detections. We do find a hint of a broad excess near the energies of high-n transitions of Sxvi (E=3.44 keV rest-frame) -- a possible signature of charge exchange in the molecular nebula and another proposed explanation for the unidentified line. While its energy is consistent with XMM pn detections, it is unlikely to explain the MOS signal. A confirmation of this interesting feature has to wait for a more sensitive observation with a future calorimeter experiment.

astro-ph.HE↗

The distribution of radioactive $^{44}$Ti in Cassiopeia A

The distribution of elements produced in the inner-most layers of a supernova explosion is a key diagnostic for studying the collapse of massive stars. Here we present the results of a 2.4 Ms \textit{NuSTAR} observing campaign aimed at studying the supernova remnant Cassiopeia A (Cas A). We perform spatially-resolved spectroscopic analyses of the $^{44}$Ti ejecta which we use to determine the Doppler shift and thus the three-dimensional (3D) velocities of the $^{44}$Ti ejecta. We find an initial $^{44}$Ti mass of 1.54 $\pm$ 0.21 $\times 10^{-4}$ M$_{\odot}$ which has a present day average momentum direction of 340$^{\circ}$ $\pm$ 15$^{\circ}$ projected on to the plane of the sky (measured clockwise from Celestial North) and tilted by 58$^{\circ}$ $\pm$ 20$^{\circ}$ into the plane of the sky away from the observer, roughly opposite to the inferred direction of motion of the central compact object. We find some $^{44}$Ti ejecta that are clearly interior to the reverse shock and some that are clearly exterior to the reverse shock. Where we observe $^{44}$Ti ejecta exterior to the reverse shock we also see shock-heated iron; however, there are regions where we see iron but do not observe $^{44}$Ti. This suggests that the local conditions of the supernova shock during explosive nucleosynthesis varied enough to suppress the production of $^{44}$Ti in some regions by at least a factor of two, even in regions that are assumed to be the result of processes like $α$-rich freezeout that should produce both iron and titanium.

astro-ph.HE↗

Study of the Polarimetric Performance of a Si/CdTe Semiconductor Compton Camera for the Hitomi Satellite

Gamma-ray polarization offers a unique probes into the geometry of the gamma-ray emission process in celestial objects. The Soft Gamma-ray Detector (SGD) onboard the X-ray observatory Hitomi is a Si/CdTe Compton camera and is expected to be an excellent polarimeter, as well as a highly sensitive spectrometer due to its good angular coverage and resolution for Compton scattering. A beam test of the final-prototype for the SGD Compton camera was conducted to demonstrate its polarimetric capability and to verify and calibrate the Monte Carlo simulation of the instrument. The modulation factor of the SGD prototype camera, evaluated for the inner and outer parts of the CdTe sensors as absorbers, was measured to be 0.649--0.701 (inner part) and 0.637--0.653 (outer part) at 122.2 keV and 0.610--0.651 (inner part) and 0.564--0.592 (outer part) at 194.5 keV at varying polarization angles with respect to the detector. This indicates that the relative systematic uncertainty of the modulation factor is as small as ~3%.

astro-ph.IM↗

The Quiescent Intracluster Medium in the Core of the Perseus Cluster

Clusters of galaxies are the most massive gravitationally-bound objects in the Universe and are still forming. They are thus important probes of cosmological parameters and a host of astrophysical processes. Knowledge of the dynamics of the pervasive hot gas, which dominates in mass over stars in a cluster, is a crucial missing ingredient. It can enable new insights into mechanical energy injection by the central supermassive black hole and the use of hydrostatic equilibrium for the determination of cluster masses. X-rays from the core of the Perseus cluster are emitted by the 50 million K diffuse hot plasma filling its gravitational potential well. The Active Galactic Nucleus of the central galaxy NGC1275 is pumping jetted energy into the surrounding intracluster medium, creating buoyant bubbles filled with relativistic plasma. These likely induce motions in the intracluster medium and heat the inner gas preventing runaway radiative cooling; a process known as Active Galactic Nucleus Feedback. Here we report on Hitomi X-ray observations of the Perseus cluster core, which reveal a remarkably quiescent atmosphere where the gas has a line-of-sight velocity dispersion of 164+/-10 km/s in a region 30-60 kpc from the central nucleus. A gradient in the line-of-sight velocity of 150+/-70 km/s is found across the 60 kpc image of the cluster core. Turbulent pressure support in the gas is 4% or less of the thermodynamic pressure, with large scale shear at most doubling that estimate. We infer that total cluster masses determined from hydrostatic equilibrium in the central regions need little correction for turbulent pressure.

astro-ph.GA↗

NuSTAR Hard X-ray Survey of the Galactic Center Region II: X-ray Point Sources

We present the first survey results of hard X-ray point sources in the Galactic Center (GC) region by NuSTAR. We have discovered 70 hard (3-79 keV) X-ray point sources in a 0.6 deg^2 region around Sgr A* with a total exposure of 1.7 Ms, and 7 sources in the Sgr B2 field with 300 ks. We identify clear Chandra counterparts for 58 NuSTAR sources and assign candidate counterparts for the remaining 19. The NuSTAR survey reaches X-ray luminosities of ~4 x and ~8 x 10^32 erg s^-1 at the GC (8 kpc) in the 3-10 and 10-40 keV bands, respectively. The source list includes three persistent luminous X-ray binaries and the likely run-away pulsar called the Cannonball. New source-detection significance maps reveal a cluster of hard (>10 keV) X-ray sources near the Sgr A diffuse complex with no clear soft X-ray counterparts. The severe extinction observed in the Chandra spectra indicates that all the NuSTAR sources are in the central bulge or are of extragalactic origin. Spectral analysis of relatively bright NuSTAR sources suggests that magnetic cataclysmic variables constitute a large fraction (>40-60%). Both spectral analysis and logN-logS distributions of the NuSTAR sources indicate that the X-ray spectra of the NuSTAR sources should have kT > 20 keV on average for a single temperature thermal plasma model or an average photon index of Gamma = 1.5 - 2 for a power-law model. These findings suggest that the GC X-ray source population may contain a larger fraction of X-ray binaries with high plasma temperatures than the field population.

astro-ph.HE↗

NuSTAR Hard X-ray Survey of the Galactic Center Region I: Hard X-ray Morphology and Spectroscopy of the Diffuse Emission

We present the first sub-arcminute images of the Galactic Center above 10 keV, obtained with NuSTAR. NuSTAR resolves the hard X-ray source IGR J17456-2901 into non-thermal X-ray filaments, molecular clouds, point sources and a previously unknown central component of hard X-ray emission (CHXE). NuSTAR detects four non-thermal X-ray filaments, extending the detection of their power-law spectra with $Γ\sim1.3$-$2.3$ up to ~50 keV. A morphological and spectral study of the filaments suggests that their origin may be heterogeneous, where previous studies suggested a common origin in young pulsar wind nebulae (PWNe). NuSTAR detects non-thermal X-ray continuum emission spatially correlated with the 6.4 keV Fe K$α$ fluorescence line emission associated with two Sgr A molecular clouds: MC1 and the Bridge. Broad-band X-ray spectral analysis with a Monte-Carlo based X-ray reflection model self-consistently determined their intrinsic column density ($\sim10^{23}$ cm$^{-2}$), primary X-ray spectra (power-laws with $Γ\sim2$) and set a lower limit of the X-ray luminosity of Sgr A* flare illuminating the Sgr A clouds to $L_X \stackrel{>}{\sim} 10^{38}$ erg s$^{-1}$. Above ~20 keV, hard X-ray emission in the central 10 pc region around Sgr A* consists of the candidate PWN G359.95-0.04 and the CHXE, possibly resulting from an unresolved population of massive CVs with white dwarf masses $M_{\rm WD} \sim 0.9 M_{\odot}$. Spectral energy distribution analysis suggests that G359.95-0.04 is likely the hard X-ray counterpart of the ultra-high gamma-ray source HESS J1745-290, strongly favoring a leptonic origin of the GC TeV emission.

astro-ph.HE↗

Calibration of the NuSTAR High Energy Focusing X-ray Telescope

We present the calibration of the \textit{Nuclear Spectroscopic Telescope Array} (\nustar) X-ray satellite. We used the Crab as the primary effective area calibrator and constructed a piece-wise linear spline function to modify the vignetting response. The achieved residuals for all off-axis angles and energies, compared to the assumed spectrum, are typically better than $\pm 2$\% up to 40\,keV and 5--10\,\% above due to limited counting statistics. An empirical adjustment to the theoretical 2D point spread function (PSF) was found using several strong point sources, and no increase of the PSF half power diameter (HPD) has been observed since the beginning of the mission. We report on the detector gain calibration, good to 60\,eV for all grades, and discuss the timing capabilities of the observatory, which has an absolute timing of $\pm$ 3\,ms. Finally we present cross-calibration results from two campaigns between all the major concurrent X-ray observatories (\textit{Chandra}, \textit{Swift}, \textit{Suzaku} and \textit{XMM-Newton}), conducted in 2012 and 2013 on the sources 3C\,273 and PKS\,2155-304, and show that the differences in measured flux is within $\sim$10\% for all instruments with respect to \nustar.

astro-ph.IM↗

Locating the most energetic electrons in Cassiopeia A

We present deep ($>$2.4 Ms) observations of the Cassiopeia A supernova remnant with {\it NuSTAR}, which operates in the 3--79 keV bandpass and is the first instrument capable of spatially resolving the remnant above 15 keV. We find that the emission is not entirely dominated by the forward shock nor by a smooth "bright ring" at the reverse shock. Instead we find that the $>$15 keV emission is dominated by knots near the center of the remnant and dimmer filaments near the remnant's outer rim. These regions are fit with unbroken power-laws in the 15--50 keV bandpass, though the central knots have a steeper ($Γ\sim -3.35$) spectrum than the outer filaments ($Γ\sim -3.06$). We argue this difference implies that the central knots are located in the 3-D interior of the remnant rather than at the outer rim of the remnant and seen in the center due to projection effects. The morphology of $>$15 keV emission does not follow that of the radio emission nor that of the low energy ($<$12 keV) X-rays, leaving the origin of the $>$15 keV emission as an open mystery. Even at the forward shock front we find less steepening of the spectrum than expected from an exponentially cut off electron distribution with a single cutoff energy. Finally, we find that the GeV emission is not associated with the bright features in the {\it NuSTAR} band while the TeV emission may be, suggesting that both hadronic and leptonic emission mechanisms may be at work.

astro-ph.HE↗

NuSTAR Observations of the Bullet Cluster: Constraints on Inverse Compton Emission

The search for diffuse non-thermal inverse Compton (IC) emission from galaxy clusters at hard X-ray energies has been undertaken with many instruments, with most detections being either of low significance or controversial. Background and contamination uncertainties present in the data of non-focusing observatories result in lower sensitivity to IC emission and a greater chance of false detection. We present 266ks NuSTAR observations of the Bullet cluster, detected from 3-30 keV. NuSTAR's unprecedented hard X-ray focusing capability largely eliminates confusion between diffuse IC and point sources; however, at the highest energies the background still dominates and must be well understood. To this end, we have developed a complete background model constructed of physically inspired components constrained by extragalactic survey field observations, the specific parameters of which are derived locally from data in non-source regions of target observations. Applying the background model to the Bullet cluster data, we find that the spectrum is well - but not perfectly - described as an isothermal plasma with kT=14.2+/-0.2 keV. To slightly improve the fit, a second temperature component is added, which appears to account for lower temperature emission from the cool core, pushing the primary component to kT~15.3 keV. We see no convincing need to invoke an IC component to describe the spectrum of the Bullet cluster, and instead argue that it is dominated at all energies by emission from purely thermal gas. The conservatively derived 90% upper limit on the IC flux of 1.1e-12 erg/s/cm^2 (50-100 keV), implying a lower limit on B>0.2μG, is barely consistent with detected fluxes previously reported. In addition to discussing the possible origin of this discrepancy, we remark on the potential implications of this analysis for the prospects for detecting IC in galaxy clusters in the future.

astro-ph.HE↗

NuSTAR results and future plans for magnetar and rotation-powered pulsar observations

The Nuclear Spectroscopic Telescope Array (NuSTAR) is the first focusing hard X-ray mission in orbit and operates in the 3-79 keV range. NuSTAR's sensitivity is roughly two orders of magnitude better than previous missions in this energy band thanks to its superb angular resolution. Since its launch in 2012 June, NuSTAR has performed excellently and observed many interesting sources including four magnetars, two rotation-powered pulsars and the cataclysmic variable AE Aquarii. NuSTAR also discovered 3.76-s pulsations from the transient source SGR J1745-29 recently found by Swift very close to the Galactic Center, clearly identifying the source as a transient magnetar. For magnetar 1E 1841-045, we show that the spectrum is well fit by an absorbed blackbody plus broken power-law model with a hard power-law photon index of ~1.3. This is consistent with previous results by INTEGRAL and RXTE. We also find an interesting double-peaked pulse profile in the 25-35 keV band. For AE Aquarii, we show that the spectrum can be described by a multi-temperature thermal model or a thermal plus non-thermal model; a multi-temperature thermal model without a non-thermal component cannot be ruled out. Furthermore, we do not see a spiky pulse profile in the hard X-ray band, as previously reported based on Suzaku observations. For other magnetars and rotation-powered pulsars observed with NuSTAR, data analysis results will be soon available.

astro-ph.HE↗

NuSTAR and Swift observations of the fast rotating magnetized white dwarf AE Aquarii

AE Aquarii is a cataclysmic variable with the fastest known rotating magnetized white dwarf (P_spin = 33.08 s). Compared to many intermediate polars, AE Aquarii shows a soft X-ray spectrum with a very low luminosity (L_X ~ 10^{31} erg/s). We have analyzed overlapping observations of this system with the NuSTAR and the Swift X-ray observatories in September of 2012. We find the 0.5-30 keV spectra to be well fitted by either an optically thin thermal plasma model with three temperatures of 0.75 +0.18 -0.45, 2.29 +0.96 -0.82, and 9.33 +6.07 -2.18 keV, or an optically thin thermal plasma model with two temperatures of 1.00 +0.34 -0.23 and 4.64 +1.58 -0.84 keV plus a power-law component with photon index of 2.50 +0.17 -0.23. The pulse profile in the 3-20 keV band is broad and approximately sinusoidal, with a pulsed fraction of 16.6 +/- 2.3%. We do not find any evidence for a previously reported sharp feature in the pulse profile.

astro-ph.SR↗

NuSTAR observations of magnetar 1E 1841-045

We report new spectral and temporal observations of the magnetar 1E 1841-045 in the Kes 73 supernova remnant obtained with the Nuclear Spectroscopic Telescope Array (NuSTAR). Combined with new Swift and archival XMM-Newton and Chandra observations, the phase-averaged spectrum is well characterized by a blackbody plus double power-law model, in agreement with previous, multi-mission X-ray results. However, we are unable to reproduce the spectral results reported using Suzaku observations. The pulsed fraction of the source is found to increase with photon energy. The measured rms pulsed fraction is ~12% and ~17% at ~20 keV and ~50 keV, respectively. We detect a new feature in the 24--35 keV band pulse profile that is uniquely double-peaked. This feature may be associated with a possible absorption or emission feature in the phase-resolved spectrum. We fit the X-ray data using the recently developed electron-positron outflow model of Beloborodov (2013) for the hard X-ray emission from magnetars. This produces a satisfactory fit allowing a constraint on the angle between the rotation and magnetic axes of the neutron star of ~20 degrees and on the angle between the rotation axis and line-of-sight of ~50 degrees. In this model, the soft X-ray component is inconsistent with a single blackbody; adding a second blackbody or a power-law component fits the data. The two-blackbody interpretation suggests a hot spot of temperature kT~0.9 keV occupying ~1% of the stellar surface.

astro-ph.HE↗

The Nuclear Spectroscopic Telescope Array (NuSTAR) Mission

The Nuclear Spectroscopic Telescope Array (NuSTAR) mission, launched on 13 June 2012, is the first focusing high-energy X-ray telescope in orbit. NuSTAR operates in the band from 3 -- 79 keV, extending the sensitivity of focusing far beyond the ~10 keV high-energy cutoff achieved by all previous X-ray satellites. The inherently low-background associated with concentrating the X-ray light enables NuSTAR to probe the hard X-ray sky with a more than one-hundred-fold improvement in sensitivity over the collimated or coded-mask instruments that have operated in this bandpass. Using its unprecedented combination of sensitivity, spatial and spectral resolution, NuSTAR will pursue five primary scientific objectives, and will also undertake a broad program of targeted observations. The observatory consists of two co-aligned grazing-incidence X-ray telescopes pointed at celestial targets by a three-axis stabilized spacecraft. Deployed into a 600 km, near-circular, 6degree inclination orbit, the Observatory has now completed commissioning, and is performing consistent with pre-launch expectations. NuSTAR is now executing its primary science mission, and with an expected orbit lifetime of ten years, we anticipate proposing a guest investigator program, to begin in Fall 2014.

astro-ph.IM↗

Spectral calibration and modeling of the NuSTAR CdZnTe pixel detectors

The Nuclear Spectroscopic Telescope Array (NuSTAR) will be the first space mission to focus in the hard X-ray (5-80 keV) band. The NuSTAR instrument carries two co-aligned grazing incidence hard X-ray telescopes. Each NuSTAR focal plane consists of four 2 mm CdZnTe hybrid pixel detectors, each with an active collecting area of 2 cm x 2 cm. Each hybrid consists of a 32 x 32 array of 605 micron pixels, read out with the Caltech custom low-noise NuCIT ASIC. In order to characterize the spectral response of each pixel to the degree required to meet the science calibration requirements, we have developed a model based on Geant4 together with the Shockley-Ramo theorem customized to the NuSTAR hybrid design. This model combines a Monte Carlo of the X-ray interactions with subsequent charge transport within the detector. The combination of this model and calibration data taken using radioactive sources of Co-57, Eu-155 and Am-241 enables us to determine electron and hole mobility-lifetime products for each pixel, and to compare actual to ideal performance expected for defect-free material.

astro-ph.IM↗

Improvements in calibration of GSO scintillators in the Suzaku Hard X-ray Detector

Improvements of in-orbit calibration of GSO scintillators in the Hard X-ray Detector on board Suzaku are reported. To resolve an apparent change of the energy scale of GSO which appeared across the launch for unknown reasons, consistent and thorough re-analyses of both pre-launch and in-orbit data have been performed. With laboratory experiments using spare hardware, the pulse height offset, corresponding to zero energy input, was found to change by ~0.5 of the full analog voltage scale, depending on the power supply. Furthermore, by carefully calculating all the light outputs of secondaries from activation lines used in the in-orbit gain determination, their energy deposits in GSO were found to be effectively lower, by several percent, than their nominal energies. Taking both these effects into account, the in-orbit data agrees with the on-ground measurements within ~5%, without employing the artificial correction introduced in the previous work (Kokubun et al. 2007). With this knowledge, we updated the data processing, the response, and the auxiliary files of GSO, and reproduced the HXD-PIN and HXD-GSO spectra of the Crab Nebula over 12-300 keV by a broken powerlaw with a break energy of ~110 keV.

astro-ph.IM↗

The Nuclear Spectroscopic Telescope Array (NuSTAR)

The Nuclear Spectroscopic Telescope Array (NuSTAR) is a NASA Small Explorer mission that will carry the first focusing hard X-ray (5 -- 80 keV) telescope to orbit. NuSTAR will offer a factor 50 -- 100 sensitivity improvement compared to previous collimated or coded mask imagers that have operated in this energy band. In addition, NuSTAR provides sub-arcminute imaging with good spectral resolution over a 12-arcminute field of view. After launch, NuSTAR will carry out a two-year primary science mission that focuses on four key programs: studying the evolution of massive black holes through surveys carried out in fields with excellent multiwavelength coverage, understanding the population of compact objects and the nature of the massive black hole in the center of the Milky Way, constraining explosion dynamics and nucleosynthesis in supernovae, and probing the nature of particle acceleration in relativistic jets in active galactic nuclei. A number of additional observations will be included in the primary mission, and a guest observer program will be proposed for an extended mission to expand the range of scientific targets. The payload consists of two co-aligned depth-graded multilayer coated grazing incidence optics focused onto solid state CdZnTe pixel detectors. To be launched in early 2012 on a Pegasus rocket into a low-inclination Earth orbit. Data will be publicly available at GSFC's High Energy Astrophysics Science Archive Research Center (HEASARC) following validation at the science operations center located at Caltech.

astro-ph.IM↗

Suzaku Constraints on the Soft and Hard Excess Emissions from Abell 2199

The nearby ($z=0.03015$) cluster of galaxies Abell~2199 was observed by Suzaku in X-rays, with five pointings for $\sim 20$ ks each. From the XIS data, the temperature and metal abundance profiles were derived out to $\sim 700$ kpc (0.4 times virial radius). Both these quantities decrease gradually from the center to peripheries by a factor of $\sim 2$, while the oxygen abundance tends to be flat. The temperature within 12' ($\sim 430$ kpc) is $\sim 4$ keV, and the 0.5--10 keV X-ray luminosity integrated up to 30' is $(2.9 \pm 0.1) \times 10^{44}$ erg s$^{-1}$, in agreement with previous XMM-Newton measurements. Above this thermal emission, no significant excess was found either in the XIS range below $\sim 1$ keV, or in the HXD-PIN range above $\sim 15$ keV. The 90%-confidence upper limit on the emission measure of an assumed 0.2 keV warm gas is (3.7--7.5) $\times 10^{62}$ cm$^{-3}$ arcmin$^{-2}$, which is 3.7--7.6 times tighter than the detection reported with XMM-Newton. The 90%-confidence upper limit on the 20--80 keV luminosity of any power law component is $1.8 \times 10^{43}$ erg s$^{-1}$, assuming a photon index of 2.0. Although this upper limit does not reject the possible 2.1$σ$ detection by the BeppoSAX PDS, it is a factor of 2.1 tighter than that of the PDS if both are considered upper limits. The non-detection of the hard excess can be reconciled with the upper limit on diffuse radio emission, without invoking the very low magnetic fields ($< 0.073 μ$G) which were suggested previously.

astro-ph.CO↗

A Galaxy Merger Scenario for the NGC 1550 Galaxy from Metal Distributions in the X-ray Emitting Plasma

The elliptical galaxy NGC 1550 at a redshift of $z=0.01239$, identified with an extended X-ray source RX J0419+0225, was observed with {\it XMM-Newton} for 31 ks. From the X-ray data and archival near infra-red data of Two Micron All Sky survay, we derive the profiles of components constituting the NGC 1550 system; the gas mass, total mass, metal mass, and galaxy luminosity. The metals (oxygen, silicon, and iron) are extended to $\sim 200$ kpc from the center, wherein $\sim$ 70% of the $K$-band luminosity is carried by NGC 1550 itself. As first revealed with {\it ASCA}, the data reconfirms the presence of a dark halo, of which the mass ($1.6 \times 10^{13} M_{\odot}$) is typical of a galaxy group rather than of a single galaxy. Within 210 kpc, the $K$-band mass-to-light ratio reaches $75 M_{\odot}/L_{\odot}$, which is comparable to those of clusters of galaxies. The iron-mass-to-light ratio profile (silicon- and oxygen mass-to-light ratio profiles as well) exhibits about two orders of magnitude decrease toward the center. Further studies comparing mass densities of metals with those of the other cluster components reveal that the iron (as well as silicon) in the ICM traces very well the total gravitating mass, whereas the stellar component is significantly more concentrated to within several tens kpc of the NGC 1550 nucleus. Thus, in the central region, the amount of metals is significantly depleted for the luminous galaxy light. Among a few possible explanations of this effect, the most likely scenario is that galaxies in this system were initially much more extended than today, and gradually fell to the center and merged into NGC 1550.

astro-ph.CO↗