SearcharxivSearch

arXiv subjects

Takashi Hasebe

Publications and source records attributed to Takashi Hasebe.

7 recordsLinked to original sources

Quantum support vector machines for classification and regression on a trapped-ion quantum computer

Quantum machine learning is a rapidly growing field at the intersection of quantum computing and machine learning. In this work, we examine our quantum machine learning models, which are based on quantum support vector classification (QSVC) and quantum support vector regression (QSVR). We investigate these models using a quantum-circuit simulator, both with and without noise, as well as the IonQ Harmony quantum processor. For the QSVC tasks, we use a dataset containing fraudulent credit card transactions and image datasets (the MNIST and the Fashion-MNIST datasets); for the QSVR tasks, we use a financial dataset and a materials dataset. For the classification tasks, the performance of our QSVC models using 4 qubits of the trapped-ion quantum computer was comparable to that obtained from noiseless quantum-circuit simulations. The result is consistent with the analysis of our device-noise simulations with varying qubit-gate error rates. For the regression tasks, applying a low-rank approximation to the noisy quantum kernel, in combination with hyperparameter tuning in ε-SVR, improved the performance of the QSVR models on the near-term quantum device. The alignment, as measured by the Frobenius inner product between the noiseless and noisy quantum kernels, can serve as an indicator of the relative prediction performance on noisy quantum devices in comparison with their ideal counterparts. Our results suggest that the quantum kernel, as described by our shallow quantum circuit, can be effectively used for both QSVC and QSVR tasks, indicating its resistance to noise and its adaptability to various datasets.

quant-ph

Ground test results of the micro-vibration interference for the x-ray microcalorimeter onboard XRISM

Resolve is a payload hosting an X-ray microcalorimeter detector operated at 50 mK in the X-Ray Imaging and Spectroscopy Mission (XRISM). It is currently under development as part of an international collaboration and is planned to be launched in 2023. A primary technical concern is the micro-vibration interference in the sensitive microcalorimeter detector caused by the spacecraft bus components. We conducted a series of verification tests in 2021-2022 on the ground, the results of which are reported here. We defined the micro-vibration interface between the spacecraft and the Resolve instrument. In the instrument-level test, the flight-model hardware was tested against the interface level by injecting it with micro-vibrations and evaluating the instrument response using the 50 mK stage temperature stability, ADR magnet current consumption rate, and detector noise spectra. We found strong responses when injecting micro-vibration at about 200, 380, and 610 Hz. In the former two cases, the beat between the injected frequency and cryocooler frequency harmonics were observed in the detector noise spectra. In the spacecraft-level test, the acceleration and instrument responses were measured with and without suspension of the entire spacecraft. The reaction wheels (RWs) and inertial reference units (IRUs), two major sources of micro-vibration among the bus components, were operated. In conclusion, the observed responses of Resolve are within the acceptable levels in the nominal operational range of the RWs and IRUs. There is no evidence that the resultant energy resolution degradation is beyond the current allocation of noise budget.

astro-ph.IM

Testbed preparation of a small prototype polarization modulator for LiteBIRD low-frequency telescope

LiteBIRD is the Cosmic Microwave Background (CMB) radiation polarization satellite mission led by ISAS/JAXA. The main scientific goal is to search for primordial gravitational wave signals generated from the inflation epoch of the Universe. LiteBIRD telescopes employ polarization modulation units (PMU) using continuously rotating half-wave plates (HWP). The PMU is a crucial component to reach unprecedented sensitivity by mitigating systematic effects, including 1/f noise. We have developed a 1/10 scale prototype PMU of the LiteBIRD LFT, which has a 5-layer achromatic HWP and a diameter of 50 mm, spanning the observational frequency range of 34-161 GHz. The HWP is mounted on a superconducting magnetic bearing (SMB) as a rotor and levitated by a high-temperature superconductor as a stator. In this study, the entire PMU system is cooled down to 10 K in the cryostat chamber by a 4-K Gifford-McMahon (GM) cooler. We propagate an incident coherent millimeter-wave polarized signal throughout the rotating HWP and detect the modulated signal. We study the modulated optical signal and any rotational synchronous signals from the rotation mechanism. We describe the testbed system and the preliminary data acquired from this setup. This testbed is built to integrate the broadband HWP PMU and evaluate the potential systematic effects in the optical data. This way, we can plan with a full-scale model, which takes a long time for preparation and testing.

astro-ph.IM

Testing magnetic interference between TES detectors and the telescope environment for future CMB satellite missions

The two most common components of several upcoming CMB experiments are large arrays of superconductive TES (Transition-Edge Sensor) detectors and polarization modulator units, e.g. continuously-rotating Half-Wave Plates (HWP). A high detector count is necessary to increase the instrument raw sensitivity, however past experiments have shown that systematic effects are becoming one of the main limiting factors to reach the sensitivity required to detect primordial $B$-modes. Therefore, polarization modulators have become popular in recent years to mitigate several systematic effects. Polarization modulators based on HWP technologies require a rotating mechanism to spin the plate and modulate the incoming polarized signal. In order to minimize heat dissipation from the rotating mechanism, which is a stringent requirement particularly for a space mission like $LiteBIRD$, we can employ a superconductive magnetic bearing to levitate the rotor and achieve contactless rotation. A disadvantage of this technique is the associated magnetic fields generated by those systems. In this paper we investigate the effects on a TES detector prototype and find no detectable $T_c$ variations due to an applied constant (DC) magnetic field, and a non-zero TES response to varying (AC) magnetic fields. We quantify a worst-case TES responsivity to the applied AC magnetic field of $\sim10^5$ pA/G, and give a preliminary interpretation of the pick-up mechanism.

astro-ph.IM

A Large Diameter Millimeter-Wave Low-Pass Filter Made of Alumina with Laser Ablated Anti-Reflection Coating

We fabricated a 302 mm diameter low-pass filter made of alumina that has an anti-reflection coating (ARC) made with laser-ablated sub-wavelength structures (SWS). The filter has been integrated into and is operating with the MUSTANG2 instrument, which is coupled to the Green Bank Telescope. The average transmittance of the filter in the MUSTANG2 operating band between 75 and 105 GHz is 98%. Reflective loss due to the ARC is 1%. The difference in transmission between the s- and p-polarization states is less than 1%. To within 1% accuracy we observe no variance in these results when transmission is measured in six independent filter spatial locations. The alumina filter replaced a prior MUSTANG2 Teflon filter. Data taken with the filter heat sunk to its nominal 40 K stage show performance consistent with expectations: a reduction of about 50% in filters-induced optical power load on the 300 mK stage, and in in-band optical loading on the detectors. It has taken less than 4 days to laser-ablate the SWS on both sides of the alumina disk. This is the first report of an alumina filter with SWS ARC deployed with an operating instrument, and the first demonstration of a large area fabrication of SWS with laser ablation.

astro-ph.IM

Search for sub-eV scalar and pseudoscalar resonances via four-wave mixing with a laser collider

The quasi-parallel photon-photon scattering by combining two-color laser fields is an approach to produce resonant states of low-mass fields in laboratory. In this system resonances can be probed via the four-wave mixing process in the vacuum. A search for scalar and pseudoscalar fields was performed by combining 9.3 $μ$J/0.9 ps Ti-Sapphire laser and 100 $μ$J/9 ns Nd:YAG laser. No significant signal of four-wave mixing was observed. We provide the upper limits on the coupling-mass relation for scalar and pseudoscalar fields, respectively, at a 95\% confidence level in the mass region below 0.15~eV.

hep-ex

The first search for sub-eV scalar fields via four-wave mixing at a quasi-parallel laser collider

A search for sub-eV scalar fields coupling to two photons has been performed via four-wave mixing at a quasi-parallel laser collider for the first time. The experiment demonstrates the novel approach to search for resonantly produced sub-eV scalar fields by combining two-color laser fields in the vacuum. The aim of this paper is to provide the concrete experimental setup and the analysis method based on specific combinations of polarization states between incoming and outgoing photons, which is extendable to higher intensity laser systems operated at high repetition rates. No significant signal of four-wave mixing was observed by combining a $0.2μ$J/0.75ns pulse laser and a 2mW CW laser on the same optical axis. Based on the prescription developed for this particular experimental approach, we obtained the upper limit at a confidence level of 95% on the coupling-mass relation.

hep-ex