SearcharxivSearch

arXiv subjects

Takashi Higuchi

Publications and source records attributed to Takashi Higuchi.

11 recordsLinked to original sources

Spin Phase Continuous Modulation: A Method for the Measurement of Neutron Monochromaticity

We present spin phase continuous modulation (SPCM), a new method for characterization of neutron beam properties. By utilizing spin-precession modulation induced by two oscillating magnetic fields, the method enables precise determination of neutron velocity and monochromaticity. We derive a theoretical formulation of the SPCM signal and experimentally validate it using measurements with a monochromatized neutron beam, obtaining reasonable agreement between experiment and prediction. SPCM enables quantitative determination of neutron beam velocity and monochromaticity.

physics.ins-det

Analysis of Multifrequency Oscillating Magnetic Fields by Neutron Spin Interferometry

We have developed a methodology for analyzing multifrequency oscillating magnetic fields using neutron spin interferometry. A theoretical formulation was derived for the contrast and the phase of the interference pattern for an input oscillating magnetic field consisting of a series of sine functions with multiple frequencies. According to the formulation, the contrast decays because of the dispersion of the Larmor precession induced by an oscillating field. The formulation also predicts that the phase of the interference pattern is not constant in contrast to single-frequency cases. We conducted an experiment on the JRR-3 C3-1-2-2 beamline to confirm the formulation in the cases of double-frequency oscillating fields in the frequency range from 2500 to 10000~Hz. The measured interference patterns showed reasonable agreement with the theoretical predictions.

physics.ins-det

Impact of a Reflecting Material on a Search for Neutron--Antineutron Oscillations using Ultracold Neutrons

We investigate neutron--antineutron oscillations of ultracold neutrons in a storage bottle represented by a one-dimensional potential. The experimental sensitivity is determined by the annihilation rate of antineutrons. Its dependence on the antineutron reflectivity and the relative phase shift between the neutron and the antineutron wavefunctions by a reflection from the wall is derived. Optimization of the antineutron pseudopotential was found crucial to maximize the sensitivity of the experiment. Furthermore, methods are discussed for determining the antineutron pseudopotential, which has only been studied indirectly thus far.

hep-ex

Isotope-selective Ion Trapping via Sympathetic Cooling using a Surface-Electrode Trap with a Hole for Collimated Atomic Loading

We developed a surface-electrode ion trap with a square hole measuring $40\,\mathrm{\mu m}$ for atomic loading. The hole was fabricated using anisotropic etching of a silicon substrate and was designed to minimize potential distortion in the trapping region. By introducing the atomic beam through the hole, we achieved enhanced isotope selectivity and experimentally demonstrated the selective trapping of calcium isotope ions using an atomic oven. We successfully prepared isotope ion pairs directly from the oven via sympathetic cooling at a rate comparable to that achieved using ablation loading. The sympathetic cooling process occurred on the order of a few seconds. We demonstrated the direct generation of an ion chain above the through-hole. This approach can be applied for trapping a wide range of ion species using a remarkably simple experimental setup, making it desirable for several applications such as quantum-charge-coupled-device (QCCD) architectures and precision measurements of isotope shifts.

quant-ph

Novel concept for low-energy antineutron production and its application for antineutron scattering experiments

Extensive data of antiproton scattering cross sections with protons and nuclei have advanced our understanding of hadronic interactions with antinucleons. However, low-energy antineutron scattering data are scarce, thereby limiting our understanding of the S-wave antinucleon-nucleon and antinucleon-nucleus interactions. We present a novel production scheme of extremely low-energy antineutrons that could remedy this situation. This method is based on backward charge-exchange reaction ($p\bar{p}\to n\bar{n}$), and can reach the lowest momentum of 9 MeV/c, which would be well suited to study of the S-wave antinucleon-nucleon or antinucleon-nucleus interactions.

nucl-ex

Precision Spectroscopy of Antiprotonic Atoms for Investigation of Low-energy Antinucleon-nucleus Interactions

We propose a high-precision x-ray spectroscopy experiment of antiprotonic atoms to advance the understanding of low-energy antinucleon-nucleus interactions. The current leading model of antiproton-nucleus interactions is based on an optical potential with parameters derived from a global fit to antiprotonic atom x-ray data across the periodic table. However, the isovector parameter of this potential remains poorly constrained due to uncertainties in nucleon distributions of the nuclei. To address this, we propose to use calcium isotopes with well-studied nucleon distributions to minimize these uncertainties. A superconducting microcalorimeter detector will provide a resolution of 50-70 eV in the energy range of interest, allowing high precision determination of the isotope-dependent strong-interaction shifts and widths. The outcomes of the proposed experiment can be used to refine the model of antinucleon-nucleus interactions and provide critical data for future experiments searching for neutron-antineutron oscillations.

nucl-ex

Towards Precision Spectroscopy of Antiprotonic Atoms for Probing Strong-field QED

PAX (antiProtonic Atom X-ray spectroscopy) is a new experiment with the aim to test strong-field quantum electrodynamics (QED) effects by performing high-precision x-ray spectroscopy of antiprotonic atoms. By utilizing advanced microcalorimeter detection techniques and a low-energy antiproton beam provided by the ELENA ring at CERN, gaseous targets will be used for the creation of antiprotonic atoms, and the measurement of transitions between circular Rydberg states will be conducted with up to two orders of magnitude improved accuracy over previous studies using high-purity germanium detectors. Our approach eliminates the longstanding issue of nuclear uncertainties that have hindered prior studies using highly charged ions, thus enabling direct and purely QED-focused measurements. By precisely probing atomic systems with electric fields up to two orders of magnitude above the Schwinger limit, PAX will test vacuum polarization and second-order QED corrections, opening new frontiers in fundamental physics and uncovering potential pathways to physics beyond the Standard Model.

physics.atom-ph

Polarized cold-neutron reflectometry at JRR-3/MINE2 for the development of ultracold-neutron spin analyzers for a neutron EDM experiment at TRIUMF

The neutron electric dipole moment (EDM) is a sensitive probe for currently undiscovered sources of charge-parity symmetry violation. As part of the TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration, we are developing spin analyzers for ultracold neutrons (UCNs) to be used for a next-generation experiment to measure the neutron EDM with unprecedented precision. Spin-state analysis of UCNs constitutes an essential part of the neutron EDM measurement sequence. Magnetized iron films used as spin filters of UCNs are crucial experimental components, whose performance directly influences the statistical sensitivity of the measurement. To test such iron film spin filters, we propose the use of polarized cold-neutron reflectometry, in addition to conventional UCN transmission experiments. The new method provides information on iron film samples complementary to the UCN tests and accelerates the development cycles. We developed a collaborative effort to produce iron film spin filters and test them with cold and ultracold neutrons available at JRR-3/MINE2 and J-PARC/MLF BL05. In this article, we review the methods of neutron EDM measurements, discuss the complementarity of this new approach to test UCN spin filters, provide an overview of our related activities, and present the first results of polarized cold-neutron reflectometry recently conducted at the MINE2 beamline.

physics.ins-det

The Precision nEDM Measurement with UltraCold Neutrons at TRIUMF

The TRIUMF Ultra-Cold Advanced Neutron (TUCAN) collaboration aims at a precision neutron electric dipole moment (nEDM) measurement with an uncertainty of $10^{-27}\,e\cdot\mathrm{cm}$, which is an order-of-magnitude better than the current nEDM upper limit and enables us to test Supersymmetry. To achieve this precision, we are developing a new high-intensity ultracold neutron (UCN) source using super-thermal UCN production in superfluid helium (He-II) and a nEDM spectrometer. The current development status of them is reported in this article.

physics.ins-det

Study of Thin Iron Films for Polarization Analysis of Ultracold Neutrons

The TUCAN (TRIUMF Ultra-Cold Advanced Neutron) collaboration aims to search for the neutron electric dipole moment (nEDM) with unprecedented precision. One of the essential elements for the nEDM measurement is a polarization analyzer of ultracold neutrons (UCNs), whose main component is a magnetized thin iron film. Several thin iron films were deposited on aluminum and silicon ubstrates and were characterized by vibrating sample magnetometry and cold-neutron reflectometry. A magnetic field required to saturate the iron film is $\sim$12 kA/m for those on the aluminum substrates and 6.4 kA/m for the silicon substrates. The magnetic potential of the iron films on the Si substrate was estimated to be 2 T by the neutron reflectometry, which is sufficient performance for an UCN polarization analyzer of the nEDM measurement.

physics.ins-det

A reservoir trap for antiprotons

We have developed techniques to extract arbitrary fractions of antiprotons from an accumulated reservoir, and to inject them into a Penning-trap system for high-precision measurements. In our trap-system antiproton storage times > 1.08 years are estimated. The device is fail-safe against power-cuts of up to 10 hours. This makes our planned comparisons of the fundamental properties of protons and antiprotons independent from accelerator cycles, and will enable us to perform experiments during long accelerator shutdown periods when background magnetic noise is low. The demonstrated scheme has the potential to be applied in many other precision Penning trap experiments dealing with exotic particles.

physics.atom-ph