SearcharxivSearch

arXiv subjects

Takehiko Tanabe

Publications and source records attributed to Takehiko Tanabe.

14 recordsLinked to original sources

Improved absolute frequency measurement of $^{171}$Yb at NMIJ with uncertainty below $2\times10^{-16}$

We report improved absolute frequency measurement of the $^{1}$S$_{0}-^{3}$P$_{0}$ transition of $^{171}$Yb at National Metrology Institute of Japan (NMIJ) by comparing the $^{171}$Yb optical lattice clock NMIJ-Yb1 with 13 Cs primary frequency standards via International Atomic Time from August 2021 to May 2023. The measured absolute frequency is 518 295 836 590 863.62(10) Hz with a fractional uncertainty of $1.9\times10^{-16}$, in good agreement with the recommended frequency of $^{171}$Yb as a secondary representation of the second. This uncertainty is 2.6 times lower than our previous measurement uncertainty, and slightly lower than any uncertainties of the absolute frequency measurements of $^{171}$Yb that have so far been reported by other institutes. We also estimate correlation coefficients between our present and previous measurements, which is important for updating the recommended frequency.

physics.atom-ph

Isotope-shift analysis with the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ transition in ytterbium

Measurements of isotope shifts have recently been attracting considerable attention due to their potentials in searching for new forces. We report on the isotope shifts of the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ transition at 431 nm in Yb, based on absolute frequency measurements with an accuracy of $\sim10$ kHz. With these data, the hyperfine constants for $^{173}$Yb are determined. To analyze these data further, electronic structure of ytterbium is theoretically calculated. The nuclear charge radii are estimated together with some previously reported isotope-shift data for other transitions. An analysis of the King plot for the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ transition shows a good consistency with other transitions, resulting in a constraint on the existence of new bosons mediating the force between an electron and a neutron. The analysis motivates further precision measurements on isotope shifts of the narrow-linewidth transitions in ytterbium, not only for the even-mass isotopes but also for the odd-mass isotopes.

physics.atom-ph

Generation of a precise time scale assisted by a near-continuously operating optical lattice clock

We report on a reduced time variation of a time scale with respect to Coordinated Universal Time (UTC) by steering a hydrogen-maser-based time scale with a near-continuously operating optical lattice clock. The time scale is generated in a post-processing analysis for 230 days with a hydrogen maser with its fractional frequency stability limited by a flicker floor of $2\times10^{-15}$ and an Yb optical lattice clock operated with an uptime of 81.6 $\%$. During the 230-day period, the root mean square time variation of our time scale with respect to UTC is 0.52 ns, which is a better performance compared with those of time scales steered by microwave fountain clocks that exhibit root mean square variations from 0.99 ns to 1.6 ns. With the high uptime achieved by the Yb optical lattice clock, our simulation implies the potential of generating a state-of-the-art time scale with a time variation of $<0.1$ ns over a month using a better hydrogen maser reaching the mid $10^{-16}$ level. This work demonstrates that a use of an optical clock with a high uptime enhances the stability of a time scale.

physics.atom-ph

Observation of the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ clock transition at 431 nm in $^{171}$Yb

We report on the observation of the $4f^{14}6s^{2}~^1S_0- 4f^{13}5d6s^{2}(J=2)$ transition at 431 nm in $^{171}$Yb by depleting atoms in a magneto-optical trap formed by the $6s^{2}~^1S_0-6s6p~^3P_1$ intercombination transition. The absolute frequency of the transition to the $F=3/2$ state is determined to be $695~171~054~858.1(8.2)$~kHz against physical realization of Coordinated Universal Time maintained by the National Metrology Institute of Japan with a frequency comb. The $g$ factor of the transition to the $F=3/2$ state and the A hyperfine constant are measured to be $g_J=1.54(13)$ and 1123.354(13)~MHz, respectively. More precise spectroscopy of this transition can lead to searches for time variation of the fine structure constant and searches for new physics with isotope shift measurements.

physics.atom-ph

Search for ultralight dark matter from long-term frequency comparisons of optical and microwave atomic clocks

We search for ultralight scalar dark matter candidates that induce oscillations of the fine structure constant, the electron and quark masses, and the quantum chromodynamics energy scale with frequency comparison data between an $^{171}$Yb optical lattice clock and a $^{133}$Cs fountain microwave clock that span 298 days with an uptime of 15.4 $\%$. New limits on the couplings of the scalar dark matter to electrons and gluons in the mass range from $10^{-22}$ eV/$c^{2}$ to $10^{-20}$ eV/$c^{2}$ are set, assuming that each of these couplings is the dominant source of the modulation in the frequency ratio. The absolute frequency of the $^{171}$Yb clock transition is also determined as $518\,295\,836\,590\,863.69(28)$ Hz, which is one of the important contributions towards a redefinition of the SI second.

physics.atom-ph

Potential for improving the local realization of coordinated universal time with a convolutional neural network

The time difference between coordinated universal time (UTC) and a hydrogen maser, which is a master oscillator for the local realization of UTC at the National Metrology Institute of Japan (NMIJ), has been predicted by using one of the deep learning techniques called a one-dimensional convolutional neural network (1D-CNN). Regarding the prediction result obtained by the 1D-CNN, we have observed improvement in the accuracy of prediction compared with that obtained by the Kalman filter. Although more investigations are required to conclude that the 1D-CNN can work as a good predictor, the present results suggest that the computational approach based on the deep learning technique may become a versatile method for improving the synchronous accuracy of UTC(NMIJ) relative to UTC.

eess.SP

Uncertainty evaluation of an $^{171}$Yb optical lattice clock at NMIJ

We report an uncertainty evaluation of an $^{171}$Yb optical lattice clock with a total fractional uncertainty of $3.6\times10^{-16}$, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the $\mathrm{6s^{2}\,^{1}S_{0}-6s6p\,^{3}P_{0}}$ clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift $d$ incorporated in a widely-used light shift model by RIKEN and the second-order Zeeman shift $a_{\mathrm{Z}}$ are improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient $d$ is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions $\mathrm{6s6p^{3}P_{0}-6s8p^{3}P_{0}}$, $\mathrm{6s8p^{3}P_{2}}$, and $\mathrm{6s5f^{3}F_{2}}$. The obtained values are $d=-1.1(4)$ $\mathrmμ$Hz and $a_{\mathrm{Z}}=-6.6(3)$ Hz/mT$^{2}$. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.

physics.atom-ph

Dual-Mode Operation of an Optical Lattice Clock Using Strontium and Ytterbium Atoms

We have developed an optical lattice clock that can operate in dual modes: a strontium (Sr) clock mode and an ytterbium (Yb) clock mode. Dual-mode operation of the Sr-Yb optical lattice clock is achieved by alternately cooling and trapping $^{87}$Sr and $^{171}$Yb atoms inside the vacuum chamber of the clock. Optical lattices for Sr and Yb atoms were arranged with horizontal and vertical configurations, respectively, resulting in a small distance of the order of 100 $μ$m between the trapped Sr and Yb atoms. The $^{1}$S$_{0}$-$^{3}$P$_{0}$ clock transitions in the trapped atoms were interrogated in turn and the clock lasers were stabilized to the transitions. We demonstrated the frequency ratio measurement of the Sr and Yb clock transitions by using the dual-mode operation of the Sr-Yb optical lattice clock. The dual-mode operation can reduce the uncertainty of the blackbody radiation shift in the frequency ratio measurement, because both Sr and Yb atoms share the same blackbody radiation.

physics.atom-ph

A frequency-stabilized light source at 399 nm using an Yb hollow-cathode lamp

We demonstrate a diode laser system operating at 399 nm that is stabilized to the ${\rm 6s^{2}\ {^1}S_{0} - 6s6p\ {^1}P_{1}}$ electric dipole transition in ytterbium (Yb) atoms in a hollow-cathode lamp. The frequency stability of the laser reached $1.1 \times 10^{-11}$ at an averaging time of $τ= 1\ \mathrm{s}$. We performed an absolute frequency measurement using an optical frequency comb and determined that the absolute frequency of the laser stabilized to the ${\rm {^1}S_{0} - {^1}P_{1}}$ transition in $^{174}\mathrm{Yb}$ was 751 526 522.26(9) MHz. We also investigated several systematic frequency shifts while changing some of the light source parameters and measured several isotope shifts. The measured laser frequency will provide useful information regarding the practical use of the frequency-stabilized light source at 399 nm.

physics.atom-ph

Second harmonic generation at 399 nm resonant on the $^{1}S_{0}-^{1}P_{1}$ transition of ytterbium using a periodically poled LiNbO$_{3}$ waveguide

We demonstrate a compact and robust method for generating a 399-nm light resonant on the $^{1}S_{0}-^{1}P_{1}$ transition in ytterbium using a single-pass periodically poled LiNbO$_{3}$ waveguide for second harmonic generation (SHG). The obtained output power at 399 nm was 25 mW when a 798-nm fundamental power of 380 mW was coupled to the waveguide. We observed no degradation of the SHG power for 13 hours with a low power of 6 mW. The obtained SHG light has been used as a seed light for injection locking, which provides sufficient power for laser cooling ytterbium.

physics.atom-ph

Absolute frequency measurements and hyperfine structures of the molecular iodine transitions at 578 nm

We report absolute frequency measurements of 81 hyperfine components of the rovibrational transitions of molecular iodine at 578 nm using the second harmonic generation of an 1156-nm external-cavity diode laser and a fiber-based optical frequency comb. The relative uncertainties of the measured absolute frequencies are typically $1.4\times10^{-11}$. Accurate hyperfine constants of four rovibrational transitions are obtained by fitting the measured hyperfine splittings to a four-term effective Hamiltonian including the electric quadrupole, spin-rotation, tensor spin-spin, and scalar spin-spin interactions. The observed transitions can be good frequency references at 578 nm, and are especially useful for research using atomic ytterbium since the transitions are close to the $^{1}S_{0}-^{3}P_{0}$ clock transition of ytterbium.

physics.atom-ph

Improved frequency measurement of the $^1S_{0}$-$^3P_{0}$ clock transition in $^{87}$Sr using the Cs fountain clock at NMIJ as a transfer oscillator

We performed an absolute frequency measurement of the $^1S_{0}$-$^3P_{0}$ transition in $^{87}$Sr with a fractional uncertainty of $1.2 \times 10^{-15}$, which is less than one third that of our previous measurement. A caesium fountain atomic clock was used as a transfer oscillator to reduce the uncertainty of the link between a strontium optical lattice clock and the SI second. The absolute value of the transition frequency is 429 228 004 229 873.56(49) Hz.

physics.atom-ph

A compact iodine-laser operating at 531 nm with stability at the 10$^{-12}$ level and using a coin-sized laser module

We demonstrate a compact iodine-stabilized laser operating at 531 nm using a coin-sized light source consisting of a 1062-nm distributed-feedback diode laser and a frequency-doubling element. A hyperfine transition of molecular iodine is observed using the light source with saturated absorption spectroscopy. The light source is frequency stabilized to the observed iodine transition and achieves frequency stability at the 10$^{-12}$ level. The absolute frequency of the compact laser stabilized to the $a_{1}$ hyperfine component of the $R(36)32-0$ transition is determined as $564\,074\,632\,419(8)$ kHz with a relative uncertainty of $1.4\times10^{-11}$. The iodine-stabilized laser can be used for various applications including interferometric measurements.

physics.optics

Frequency ratio measurement of 171Yb and 87Sr optical lattice clocks

The frequency ratio of the 1S0(F=1/2)-3P0(F=1/2) clock transition in 171Yb and the 1S0(F=9/2)-3P0(F=9/2) clock transition in 87Sr is measured by an optical-optical direct frequency link between two optical lattice clocks. We determined the ratio (ν_{Yb}/ν_{Sr}) to be 1.207 507 039 343 340 4(18) with a fractional uncertainty of 1.5x10^{-15}. The measurement uncertainty of the frequency ratio is smaller than that obtained from absolute frequency measurements using the International Atomic Time (TAI) link. The measured ratio agrees well with that derived from the absolute frequency measurement results obtained at NIST and JILA, Boulder, CO using their Cs-fountain clock. Our measurement enables the first international comparison of the frequency ratios of optical clocks, and we obtained a good agreement between the two measured ratios with an uncertainty smaller than the TAI link. The measured frequency ratio will be reported to the International Committee for Weights and Measures for a discussion related to the redefinition of the second.

physics.atom-ph