SearcharxivSearch

arXiv subjects

Takuto Kiyomoto

Publications and source records attributed to Takuto Kiyomoto.

2 recordsLinked to original sources

Investigation of magnetic-field effects on photomultiplier tubes for the first Large-Sized Telescope of the Cherenkov Telescope Array Observatory

Photomultiplier tubes (PMTs) are widely used in imaging atmospheric Cherenkov telescopes. Their response can depend on the telescope pointing direction through changes in their orientation relative to the geomagnetic field. Such a dependence was indicated during the calibration campaign of the CTAO LST-1. In this work, the LST-1 calibration data are analyzed to quantify the gain dependence in terms of the geomagnetic field, and dedicated laboratory measurements are performed to test the hypothesis that the observed dependence originates from magnetic-field effects. Both the on-site and laboratory measurements show a consistent dependence of the PMT gain on the magnetic field, while the laboratory measurements further separate the effects on the gain and the excess noise factor. These results provide a clearer understanding of the gain variation observed in LST-1 in terms of magnetic-field effects.

astro-ph.IM

Competition between Increasing and Decreasing Effects of the Afterpulsing Rate of PMTs during Night-Sky Observations

Photomultiplier tubes (PMTs) have been widely used in imaging atmospheric Cherenkov telescopes (IACTs). The Large-Sized Telescopes (LSTs) of the Cherenkov Telescope Array Observatory (CTAO), the latest-generation IACTs, are optimized for challenging observations of low-energy gamma rays, specifically in the 20 to 150 GeV range. To this end, PMTs with an exceptionally low afterpulsing probability have been developed and installed. However, the afterpulsing rate increases over time due to the infiltration of atmospheric molecules, particularly helium, into the tube. Interestingly, we found that the afterpulsing rate decreases when PMTs are operated at high voltage and exposed to light -- a condition naturally met during IACT observations. To evaluate the latest instrument response, after five years of operation, we removed several PMTs from the first LST, which is currently the only operational telescope among the CTAO instruments. Our laboratory measurements showed no increase in afterpulsing compared to pre-installation values. This suggests that the decrease in afterpulsing during operation offsets the increase, thereby maintaining the long-term performance of the PMTs.

astro-ph.IM