SearcharxivSearch

arXiv subjects

Takuya Kawasaki

Publications and source records attributed to Takuya Kawasaki.

7 recordsLinked to original sources

Sensitivity Enhancement in Atom-Interferometer Gyroscopes via Phase-Modulation Signal Readout Scheme

Quantum sensors based on atom interferometers are advancing both fundamental physics and practical applications, with higher sensitivity being a key requirement for these investigations. Here, we experimentally demonstrate a sensitivity enhancement of an atom-interferometer gyroscope using a phase-modulation signal readout scheme. Phase modulation applied to the laser light used for atomic state manipulation is transferred to the atomic phase and read out via multi-harmonic demodulation. The observed sensitivity improvement factor of $1.20\pm0.04$ over the conventional phase sweep scheme agrees with theoretical predictions. We also found that phase-dispersion compensation control, which compensates atomic velocity dispersion and preserves interference contrast at high angular rates, effectively eliminates the nonlinearity inherent in multi-harmonic demodulation. The sensitivity improvement achieved by our method is applicable to a broad class of atom interferometers and requires no modifications to the optical or vacuum systems, making it particularly effective for size-constrained applications such as large-baseline experiments and inertial navigation systems.

physics.atom-ph

Closed-loop measurements in an atom interferometer gyroscope with velocity-dependent phase-dispersion compensation

Atom interferometer-based gyroscopes are expected to have a wide range of applications due to their high sensitivity. However, their dynamic range is limited by dephasing caused by velocity-dependent Sagnac phase shift in combination with the longitudinal velocity distribution of the atoms, restricting measurements of large angular velocities. In this study, we present a method for restoring the contrast deterioration in angular velocity measurements with interferometer gyroscopes using atomic beams. Our findings show that by introducing the pseudo-rotation effect with appropriate two-photon detunings for Raman lights in the interferometer, it is possible to effectively cancel the Sagnac phase shift for all atoms in the velocity distribution of the beam. Consequently, the contrast is unaffected by the rotation. Furthermore, we applied this method to an interferometer gyroscope with counter-propagating atomic beams sharing the same Raman lights. It is found that the angular velocity of the system can be estimated through the detuning point where the phase difference between the two interferometers is zero. This approach ensures that the scale factor of the atom interferometer gyroscope is independent of the change in the longitudinal velocity distribution of the atomic beam. We demonstrate our technique using the interferometer gyroscope of thermal atomic beams of rubidium-87, achieving a measurement of angular velocity of $\mathrm{{1.0}^{\circ}/s}$ even with an acceleration of 0.68$\mathrm{m/s^2}$ on a three-axis rotation table. This simple and robust dispersion compensation method with Raman light detuning benefits dynamic angular velocity measurements in field applications such as the inertial navigation of vehicles.

physics.atom-ph

Analyzing the sensitivity of an atom interferometer with a phase-modulation readout scheme

The sensitivity of an interferometer depends on its readout scheme. However, little attention has been paid to the readout schemes of atom interferometers from the viewpoint of their sensitivity. The difference in sensitivity between readout schemes or their optimization has not been considered in the literature. Herein we analytically calculate the sensitivities of an atom interferometer with typical readout schemes by applying the two-photon formalism, which was developed for optical interferometers to deal with quantum noise. Our calculations reveal that by using sinusoidal phase modulation, the sensitivity can surpass that obtained by the conventional phase sweeping scheme. The superiority of this phase modulation scheme for both cold and thermal atomic beams is demonstrated. In addition, we show that the phase modulation scheme is advantageous for atom-flux fluctuation and resists atom-flux drift. This study performs a general analysis of the sensitivity of atom interferometers and identifies an advantageous readout scheme.

physics.atom-ph

Angular trapping of a linear-cavity mirror with an optical torsional spring

Optomechanical systems have been attracting intensive attention in various physical experiments. With an optomechanical system, the displacement of or the force acting on a mechanical oscillator can be precisely measured by utilizing optical interferometry. As a mechanical oscillator, a suspended mirror is often used in over milligram scale optomechanical systems. However, the tiny suspended mirror in a linear cavity can be unstable in its yaw rotational degree of freedom due to optical radiation pressure. This instability curbs the optical power that the cavity can accumulate in it, and imposes a limitation on the sensitivity. Here, we show that the optical radiation pressure can be used to trap the rotational motion of the suspended mirror without additional active feedback control when the $g$ factors of the cavity are negative and one mirror is much heavier than the other one. Furthermore, we demonstrate experimentally the validity of the trapping. We measured the rotational stiffness of a suspended tiny mirror with various intracavity power. The result indicates that the radiation pressure of the laser beam inside the cavity actually works as a positive restoring torque. Moreover, we discuss the feasibility of observing quantum radiation pressure fluctuation with our experimental setup as an application of our trapping configuration.

quant-ph

Improving force sensitivity by amplitude measurement of light reflected from a detuned optomechanical cavity

The measurement of weak continuous forces exerted on a mechanical oscillator is a fundamental problem in various physical experiments. It is fundamentally impeded by quantum back-action from the meter used to sense the displacement of the oscillator. In the context of interferometric displacement measurements, we here propose and demonstrate the working principle of a scheme for coherent back-action cancellation. By measuring the amplitude quadrature of the light reflected from a detuned optomechanical cavity inside which a stiff optical spring is generated, back-action can be cancelled in a narrow band of frequencies. This method provides a simple way to improve the sensitivity in experiments limited by quantum back-action without injection of squeezed light or stable homodyne readout.

quant-ph

Optical trapping of the transversal motion for an optically levitated mirror

Optomechanical systems are suitable for elucidating quantum phenomena at the macroscopic scale in the sense of the mass scale. The systems should be well-isolated from the environment to avoid classical noises, which conceal quantum signals. Optical levitation is a promising way to isolate optomechanical systems from the environment. To realize optical levitation, all degrees of freedom need to be trapped. Until now, longitudinal trapping and rotational trapping of a mirror with optical radiation pressure have been studied in detail and validated with various experiments. However, less attention has been paid to the transversal trapping of a mirror. Herein, we report a pioneering result where we experimentally confirmed transversal trapping of a mirror of a Fabry-Pérot cavity using a torsional pendulum. Through this demonstration, we experimentally proved that optical levitation is realizable with only two Fabry-Pérot cavities that are aligned vertically. This work paves the way toward optical levitation and realizing a macroscopic quantum system.

quant-ph

DANCE: Dark matter Axion search with riNg Cavity Experiment

We have proposed a new approach to search for axion dark matter with an optical ring cavity [Phys. Rev. Lett. 121, 161301 (2018)]. The coupling of photons to axions or axion-like particles makes a modulated difference in the phase velocity between left- and right-handed photons. Our method is to measure this phase velocity difference with a ring cavity, by measuring the resonant frequency difference between two circular polarizations. Our estimation shows that the sensitivity to axion-photon coupling constant $g_{a γ}$ for axion mass $m \lesssim 10^{-10}$ eV can be improved by several orders of magnitude compared with the current best limits. In this paper, we present the principles of the Dark matter Axion search with riNg Cavity Experiment (DANCE) and the status of the prototype experiment, DANCE Act-1.

physics.ins-det