SearcharxivSearch

arXiv subjects

Takuya Miyazawa

Publications and source records attributed to Takuya Miyazawa.

4 recordsLinked to original sources

Refined Constraints on the Hard X-ray Polarization of the Crab Pulsar and Nebula Derived from an Extended XL-Calibur Dataset

We present updated hard X-ray polarization measurements of the Crab pulsar and nebula obtained with the balloon-borne polarimeter XL-Calibur in the ~19-64 keV energy range. During the flight, intermittent GPS-failure resulted in poorly constrained timing for ~38% of the Crab dataset. By implementing a new phase-recovery method that reconstructs timing during extended GPS-off intervals, phase tag data is recovered for ~95% of the GPS-off dataset, increasing the precision of the phase-resolved analysis. Phase-information for the data is recovered by using the Crab pulsar, with its 33 ms period, as an external timing source. Using a Markov-Chain Monte-Carlo framework to jointly fit phase offsets and frequency derivatives, sufficient phase accuracy is achieved, across multiple periods without GPS for a phase-resolved analysis. This enables inclusion of nearly the full dataset in the polarization study. The polarization degree of the nebular emission is found to be (27.7${\pm}$4.9)% at a polarization angle of 127.2°${\pm}$5.1° confirming previous XL-Calibur results and remaining aligned with the Crab's spin axis, consistent with synchrotron emission from the inner nebula. Phase-resolved measurements show that the off-pulse and bridge intervals exhibit a strong polarization, while the pulsar peaks, although weakly constrained, remain in agreement with the softer-energy trends of IXPE. These findings reinforce a scenario in which hard X-ray emission arises primarily in the nebular torus and wind regions. The successful recovery of precise phase tagging from GPS-off data demonstrates the capacity to use the pulsar as an external clock even in the case of sparsely populated data.

astro-ph.HE

XL-Calibur measurements of polarised hard X-ray emission from the Crab

We report measurements of the linear polarisation degree (PD) and angle (PA) for hard X-ray emission from the Crab pulsar and wind nebula. Measurements were made with the XL-Calibur ($\sim$15-80 keV) balloon-borne Compton-scattering polarimeter in July 2024. The polarisation parameters are determined using a Bayesian analysis of Stokes parameters obtained from X-ray scattering angles. Well-constrained ($\sim$8.5$σ$) results are obtained for the polarisation of the $\sim$19-64 keV signal integrated over all pulsar phases: PD=(25.1$\pm$2.9)% and PA=(129.8$\pm$3.2)$^\circ$. In the off-pulse (nebula-dominated) phase range, the PD is constrained at $\sim$4.5$σ$ and is compatible with the phase-integrated result. The PA of the nebular hard X-ray emission aligns with that measured by IXPE in the 2-8 keV band for the toroidal inner region of the pulsar wind nebula, where the hard X-rays predominantly originate. For the main pulsar peak, PD=(32.8$^{+18.2}_{-28.5}$)% and PA=(156.0 $\pm$ 21.7)$^\circ$, while for the second peak (inter-pulse), PD=(0.0$^{+33.6}_{-0.0}$)% and PA=(154.5 $\pm$ 34.5)$^\circ$. A low level of polarisation in the pulsar peaks likely does not favour emission originating from the inner regions of the pulsar magnetosphere. Discriminating between Crab pulsar emission models will require deeper observations, e.g. with a satellite-borne hard X-ray polarimeter.

astro-ph.HE

Imaging and spectral performance of CdTe double-sided strip detectors for the Hard X-ray Imager onboard ASTRO-H

The imaging and spectral performance of CdTe double-sided strip detectors (CdTe-DSDs) was evaluated for the ASTRO-H mission. The charcterized CdTe-DSDs have a strip pitch of 0.25 mm, an imaging area of 3.2 cm$\times$3.2 cm and a thickness of 0.75 mm. The detector was successfully operated at a temperature of $-20^\circ$C and with an applied bias voltage of 250 V. By using two-strip events as well as one-strip events for the event reconstruction, a good energy resolution of 2.0 keV at 59.5 keV and a sub-strip spatial resolution was achieved. The hard X-ray and gamma-ray response of CdTe-DSDs is complex due to the properties of CdTe and the small pixel effect. Therefore, one of the issues to investigate is the response of the CdTe-DSD. In order to investigate the spatial dependence of the detector response, we performed fine beam scan experiments at SPring-8, a synchrotron radiation facility. From these experiments, the depth structure of the electric field was determined as well as properties of carriers in the detector and successfully reproduced the experimental data with simulated spectra.

astro-ph.IM

The ASTRO-H Mission

The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe by performing high-resolution, high-throughput spectroscopy with moderate angular resolution. ASTRO-H covers very wide energy range from 0.3 keV to 600 keV. ASTRO-H allows a combination of wide band X-ray spectroscopy (5-80 keV) provided by multilayer coating, focusing hard X-ray mirrors and hard X-ray imaging detectors, and high energy-resolution soft X-ray spectroscopy (0.3-12 keV) provided by thin-foil X-ray optics and a micro-calorimeter array. The mission will also carry an X-ray CCD camera as a focal plane detector for a soft X-ray telescope (0.4-12 keV) and a non-focusing soft gamma-ray detector (40-600 keV) . The micro-calorimeter system is developed by an international collaboration led by ISAS/JAXA and NASA. The simultaneous broad bandpass, coupled with high spectral resolution of Delta E ~7 eV provided by the micro-calorimeter will enable a wide variety of important science themes to be pursued.

astro-ph.IM