Searcharxiv⌕ Search

arXiv subjects

Talita Perciano

Publications and source records attributed to Talita Perciano.

21 records · Page 2Linked to original sources

Nanosurveyor: a framework for real-time data processing

Scientists are drawn to synchrotrons and accelerator based light sources because of their brightness, coherence and flux. The rate of improvement in brightness and detector technology has outpaced Moore's law growth seen for computers, networks, and storage, and is enabling novel observations and discoveries with faster frame rates, larger fields of view, higher resolution, and higher dimensionality. Here we present an integrated software/algorithmic framework designed to capitalize on high throughput experiments, and describe the streamlined processing pipeline of ptychography data analysis. The pipeline provides throughput, compression, and resolution as well as rapid feedback to the microscope operators.

physics.ins-det↗

SHARP: a distributed, GPU-based ptychographic solver

Ever brighter light sources, fast parallel detectors, and advances in phase retrieval methods, have made ptychography a practical and popular imaging technique. Compared to previous techniques, ptychography provides superior robustness and resolution at the expense of more advanced and time consuming data analysis. By taking advantage of massively parallel architectures, high-throughput processing can expedite this analysis and provide microscopists with immediate feedback. These advances allow real-time imaging at wavelength limited resolution, coupled with a large field of view. Here, we introduce a set of algorithmic and computational methodologies used at the Advanced Light Source, and DOE light sources packaged as a CUDA based software environment named SHARP (http://camera.lbl.gov/sharp), aimed at providing state-of-the-art high-throughput ptychography reconstructions for the coming era of diffraction limited light sources.

physics.data-an↗

Deconvolution of vibroacoustic images using a simulation model based on a three dimensional point spread function

Vibro-acoustography (VA) is a medical imaging method based on the difference-frequency generation produced by the mixture of two focused ultrasound beams. VA has been applied to different problems in medical imaging such as imaging bones, microcalcifications in the breast, mass lesions, and calcified arteries. The obtained images may have a resolution of 0.7--0.8 mm. Current VA systems based on confocal or linear array transducers generate C-scan images at the beam focal plane. Images on the axial plane are also possible, however the system resolution along depth worsens when compared to the lateral one. Typical axial resolution is about 1.0 cm. Furthermore, the elevation resolution of linear array systems is larger than that in lateral direction. This asymmetry degrades C-scan images obtained using linear arrays. The purpose of this article is to study VA image restoration based on a 3D point spread function (PSF) using classical deconvolution algorithms: Wiener, constrained least-squares (CLSs), and geometric mean filters. To assess the filters' performance, we use an image quality index that accounts for correlation loss, luminance and contrast distortion. Results for simulated VA images show that the quality index achieved with the Wiener filter is 0.9 (1 indicates perfect restoration). This filter yielded the best result in comparison with the other ones. Moreover, the deconvolution algorithms were applied to an experimental VA image of a phantom composed of three stretched 0.5 mm wires. Experiments were performed using transducer driven at two frequencies, 3075 kHz and 3125 kHz, which resulted in the difference-frequency of 50 kHz. Restorations with the theoretical line spread function (LSF) did not recover sufficient information to identify the wires in the images. However, using an estimated LSF the obtained results displayed enough information to spot the wires in the images.

cs.CV↗