SearcharxivSearch

arXiv subjects

Tania K. Morimoto

Publications and source records attributed to Tania K. Morimoto.

4 recordsLinked to original sources

Pneumatic Units for Logic-based Sequential Excitation (PULSE) in Wearable Haptic Devices

Soft, wearable robotic devices can deliver haptic feedback to support a wide range of tasks, such as extended reality, training various skills, and rehabilitation. Pneumatic actuation can deliver complex haptic feedback, is lightweight and compliant, and can be incorporated into textiles, making it promising for wearable applications. These soft pneumatic devices, however, typically require a valve and input for each pneumatic actuator, making it challenging to develop fully portable devices for at-home use. In this work we present a pneumatic unit for logic-based sequential excitation (PULSE). The PULSE is a flat, textile-based pneumatic actuator with embedded fluidic logic. By combining these actuators into a fluidic ring oscillator, we decreased the typical amount of required pneumatic inputs for a haptic forearm sleeve by 60%, with the ability to scale. We built the ring oscillator by optimizing design variables to reach desired periods of oscillation. We demonstrated a set of tactile stroking cues with periods ranging from 1.16 to 1.56 s and forces ranging from 1.07 to 2.04 N. We assessed the sleeve's ability to render differentiable, pleasant, and continuous haptic cues in a user study. The forearm sleeve containing PULSEs successfully delivered four directional cues and guided users to target wrist angles with fast reaction times, low overshoot amounts, and a 93.3% average accuracy of correct initial directions.

cs.HC

A Task-Agnostic Control Strategy for Dynamic Assistance with Pneumatically Actuated Soft Exosuits

Pneumatic artificial muscles have provided new opportunities to develop upper-extremity soft exosuits for reha- bilitation, augmentation, and assisted daily living. However, the complex dynamics and limited bandwidth of these actuators has made providing responsive assistance based on user intention a longstanding challenge. In this work, we present an inverse-plant control strategy for pneumatically actuated soft exosuits that only relies on kinematic sensing for task-agnostic and dynamic assistance during daily living. We model the human-robot system using a Hammerstein dynamic model, consisting of a Preisach hysteresis model and a linear time-invariant filter, to capture the static and dynamic behavior of the system. We personalize our model to each user using 140 s of data and approximate an inverse to integrate into our control loop. When evaluated on a test rig that emulated a soft assistive exosuit for the wrist, our controller reduced the interaction torque by up to 73% and the activation of key flexor and extensor muscles by up to 47% relative to the condition with no assistance for speeds ranging from 8°/s to 120°/s. Overall, this work presents a control strategy that can provide task-agnostic, dynamic assistance with pneumatically actuated soft exosuits without the need for physiological or force sensors to interpret user intention.

cs.RO

CASAband: Easy-to-Wear Textile Wristband using Shape Memory Alloy Actuators for Spatial and Temporal Haptic Feedback

Haptic interfaces for the wrist and forearm offer an attractive alternative to hand-worn devices as they are simple to wear, leave the hands free for interaction with the real world, and interfere minimally with natural arm motions. To be useful in real-world settings, however, such devices must balance functionality, wearability and comfort, all while being fully untethered with minimal mass and volume. In this work, we present CASAband, a haptic wristband that integrates compliant amplified shape memory alloy actuators (CASA) into a multi-layered textile wristband to deliver spatial and temporal haptic feedback. CASAband operates completely untethered, generates no noise, and has a total mass of 63 g. The device incorporates four actuators that can generate up to 1.7 N of blocked force and 3.2 mm of free displacement with an operating bandwidth ranging from 1.34-6.59 Hz depending on the applied voltage. We conducted a perceptual study and determined that users could identify the location of a single haptic cue around their wrist and discriminate among several patterned cues with over 90% accuracy on average, highlighting that CASAband can be a suitable wearable interface to deliver information for real-world guidance and navigation tasks. To highlight the potential use cases for CASAband, we conducted two demonstrations: a pick and place task where the user relied only on haptic communication from a moderator, and an outdoor pedestrian navigation task where the user relied only on directional cues on the wrist. CASAband is one of the first haptic interfaces that balances the tradeoff between form and function and presents new opportunities for haptic feedback in the real world

cs.HC

Contact-Aware Planning and Control of Continuum Robots in Highly Constrained Environments

Continuum robots are well suited for navigating confined and fragile environments, such as vascular or endoluminal anatomy, where contact with surrounding structures is often unavoidable. While controlled contact can assist motion, unfavorable contact can degrade controllability, induce kinematic singularities, or introduce safety risks. We present a contact-aware planning approach that evaluates contact quality, penalizing hazardous interactions, while permitting benign contact. The planner produces kinematically feasible trajectories and contact-aware Jacobians which can be used for closed-loop control in hardware experiments. We validate the approach by testing the integrated system (planning, control, and mechanical design) on anatomical models from patient scans. The planner generates effective plans for three common anatomical environments, and, in all hardware trials, the continuum robot was able to reach the target while avoiding dangerous tip contact (100% success). Mean tracking errors were 1.9 +/- 0.5 mm, 1.2 +/- 0.1 mm, and 1.7 +/- 0.2 mm across the three different environments. Ablation studies showed that penalizing end-of-continuum-segment (ECS) contact improved manipulability and prevented hardware failures. Overall, this work enables reliable, contact-aware navigation in highly constrained environments.

cs.RO