Magnetic resonance imaging assessment of the suitability and consistency of radiotherapy treatment positioning achieved using intra-oral stents

As head-and-neck radiotherapy treatments grow more complex and precise, it becomes increasingly important to assess the anatomical separations that can be achieved using intra-oral stents. A series of twenty T2-weighted turbo spin echo magnetic resonance images (MRI) were acquired of one healthy participant, with a range of different wax and 3D printed intra-oral stents in situ. The resulting measurements showed that a 3D printed modular stent containing hard polylactic acid (PLA) and flexible thermoplastic polyurethane (TPU) components made the largest and most reproducible separation between the cheeks (70.8 +/- 0.3 mm), two hard PLA stents designed to exactly fit the participant's teeth produced the poorest positioning reproducibility (standard deviations of up to 3 mm between a range of landmarks measured in repeated images). Most stents were described as ``comfortable'' although the wax stents left small pieces of wax attached to the teeth after use. This MRI based comparison demonstrated that the materials and designs used for intra-oral stents can have substantial effects on the level of anatomical separation and positioning reproducibility that they produce.

physics.med-ph

Patient-specific immobilisation for radiotherapy treatment of extensive lower-limb carcinoma

When non-melanoma skin cancers extend over large areas of skin, effective radiotherapy treatments can be delivered using volumetric modulated arc therapy (VMAT) beams with narrow segments that rotate around the affected surfaces. For lower-limb carcinoma treatments, careful immobilisation is needed to achieve the degree of reproducible and stable positioning required to ensure the narrow field segments treat the targeted tissue and avoid underlying anatomy. To meet this need, a 3D printed patient-specific foot support was created in the form of a solid box containing a deep ``footprint'', shaped to match the outline of the patient's relaxed foot when lying supine, supported by a vacuum bag. For our first patient treated with a 3D printed foot support, image guidance data and clinical notes were evaluated against corresponding information from all recent lower-leg VMAT treatments. The patient feedback was recorded as ``good'', with no complaints of discomfort or poor fit, and the proportion of treatment fractions requiring shifts greater than 5 mm after setup imaging (20\%) compared favourably to the proportions for patients without a patient-specific foot support (23\%-84\%). The patient-specific foot support was particularly useful for minimising longitudinal shifts and leg rotations. Evidently, 3D-printed patient-specific immobilisation devices have the potential to enhance positioning stability, and therefore potentially improve accuracy and effectiveness of VMAT treatments, for patients with extensive lower-limb carcinomas.

physics.med-ph