Searcharxiv⌕ Search

arXiv subjects

Tanmoy Chattopadhyay

Publications and source records attributed to Tanmoy Chattopadhyay.

At least 37 records · Page 2Linked to original sources

Demonstrating sub-electron noise performance in Single electron Sensitive Readout (SiSeRO) devices

Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detection technology that can, in principle, provide significantly greater responsivity and improved noise performance than traditional charge coupled device (CCD) readout circuitry. The SiSeRO, developed by MIT Lincoln Laboratory, uses a p-MOSFET transistor with a depleted back-gate region under the transistor channel; as charge is transferred into the back gate region, the transistor current is modulated. With our first generation SiSeRO devices, we previously achieved a responsivity of around 800 pA per electron, an equivalent noise charge (ENC) of 4.5 electrons root mean square (RMS), and a full width at half maximum (FWHM) spectral resolution of 130 eV at 5.9 keV, at a readout speed of 625 Kpixel/s and for a detector temperature of 250 K. Importantly, since the charge signal remains unaffected by the SiSeRO readout process, we have also been able to implement Repetitive Non-Destructive Readout (RNDR), achieving an improved ENC performance. In this paper, we demonstrate sub-electron noise sensitivity with these devices, utilizing an enhanced test setup optimized for RNDR measurements, with excellent temperature control, improved readout circuitry, and advanced digital filtering techniques. We are currently fabricating new SiSeRO detectors with more sensitive and RNDR-optimized amplifier designs, which will help mature the SiSeRO technology in the future and eventually lead to the pathway to develop active pixel sensor (APS) arrays using sensitive SiSeRO amplifiers on each pixel. Active pixel devices with sub-electron sensitivity and fast readout present an exciting option for next generation, large area astronomical X-ray telescopes requiring fast, low-noise megapixel imagers.

astro-ph.IM↗

The XOC X-ray Beamline: Probing Colder, Quieter, and Softer

Future strategic X-ray satellite telescopes, such as the probe-class Advanced X-ray Imaging Satellite (AXIS), will require excellent soft energy response in their imaging detectors to enable maximum discovery potential. In order to characterize Charge-Coupled Device (CCD) and Single Electron Sensitive Read Output (SiSeRO) detectors in the soft X-ray region, the X-ray Astronomy and Observational Cosmology (XOC) group at Stanford has developed, assembled, and commissioned a 2.5-meter-long X-ray beamline test system. The beamline is designed to efficiently produce monoenergetic X-ray fluorescence lines in the 0.3-10 keV energy range and achieve detector temperatures as low as 173 K. We present design and simulation details of the beamline, and discuss the vacuum, cooling, and X-ray fluorescence performance achieved. As a workhorse for future detector characterization at Stanford, the XOC beamline will support detector development for a broad range of X-ray astronomy instruments.

astro-ph.IM↗

X-ray speed reading with the MCRC: prototype success and next generation upgrades

The Advanced X-ray Imaging Satellite (AXIS) is a NASA probe class mission concept designed to deliver arcsecond resolution with an effective area ten times that of Chandra (at launch). The AXIS focal plane features an MIT Lincoln Laboratory (MIT-LL) X-ray charge-coupled device (CCD) detector working in conjunction with an application specific integrated circuit (ASIC), denoted the Multi-Channel Readout Chip (MCRC). While this readout ASIC targets the AXIS mission, it is applicable to a range of potential X-ray missions with comparable readout requirements. Designed by the X-ray astronomy and Observational Cosmology (XOC) group at Stanford University, the MCRC ASIC prototype (MCRC-V1.0) uses a 350 nm technology node and provides 8 channels of high speed, low noise, low power consumption readout electronics. Each channel implements a current source to bias the detector output driver, a preamplifier to provide gain, and an output buffer to interface directly to an analog-to-digital (ADC) converter. The MCRC-V1 ASIC exhibits comparable performance to our best discrete electronics implementations, but with ten times less power consumption and a fraction of the footprint area. In a total ionizing dose (TID) test, the chip demonstrated a radiation hardness equal or greater to 25 krad, confirming the suitability of the process technology and layout techniques used in its design. The next iteration of the ASIC (MCRC-V2) will expand the channel count and extend the interfaces to external circuits, advancing its readiness as a readout-on-a-chip solution for next generation X-ray CCD-like detectors. This paper summarizes our most recent characterization efforts, including the TID radiation campaign and results from the first operation of the MCRC ASIC in combination with a representative MIT-LL CCD.

astro-ph.IM↗

Towards efficient machine-learning-based reduction of the cosmic-ray induced background in X-ray imaging detectors: increasing context awareness

Traditional cosmic ray filtering algorithms used in X-ray imaging detectors aboard space telescopes perform event reconstruction based on the properties of activated pixels above a certain energy threshold, within 3x3 or 5x5 pixel sliding windows. This approach can reject up to 98% of the cosmic ray background. However, the remaining unrejected background constitutes a significant impediment to studies of low surface brightness objects, which are especially prevalent in the high-redshift universe. The main limitation of the traditional filtering algorithms is their ignorance of the long-range contextual information present in image frames. This becomes particularly problematic when analyzing signals created by secondary particles produced during interactions of cosmic rays with body of the detector. Such signals may look identical to the energy deposition left by X-ray photons, when one considers only the properties within the small sliding window. Additional information is present, however, in the spatial and energy correlations between signals in different parts of the frame, which can be accessed by modern machine learning (ML) techniques. In this work, we continue the development of an ML-based pipeline for cosmic ray background mitigation. Our latest method consist of two stages: first, a frame classification neural network is used to create class activation maps (CAM), localizing all events within the frame; second, after event reconstruction, a random forest classifier, using features obtained from CAMs, is used to separate X-ray and cosmic ray features. The method delivers >40% relative improvement over traditional filtering in background rejection in standard 0.3-10keV energy range, at the expense of only a small (<2%) level of lost X-ray signal. Our method also provides a convenient way to tune the cosmic ray rejection threshold to adapt to a user's specific scientific needs.

astro-ph.IM↗

Localisation of Gamma Ray Bursts using AstroSat Mass Model

The Cadmium Zinc Telluride Imager (CZTI) aboard AstroSat has good sensitivity to Gamma Ray Bursts (GRBs), with close to 600 detections including about 50 discoveries undetected by other missions. However, CZTI was not designed to be a GRB monitor and lacks localisation capabilities. We introduce a new method of localising GRBs using "shadows" cast on the CZTI detector plane due to absorption and scattering by satellite components and instruments. Comparing the observed distribution of counts on the detector plane with simulated distributions with the AstroSat Mass Model, we can localise GRBs in the sky. Our localisation uncertainty is defined by a two-component model, with a narrow Gaussian component that has close to 50% probability of containing the source, and the remaining spread over a broader Gaussian component with an 11.3 times higher $σ$. The width ($σ$) of the Gaussian components scales inversely with source counts. We test this model by applying the method to GRBs with known positions and find good agreement between the model and observations. This new ability expands the utility of CZTI in the study of GRBs and other rapid high-energy transients.

astro-ph.HE↗

Demonstrating repetitive non-destructive readout (RNDR) with SiSeRO devices

We demonstrate so-called repetitive non-destructive readout (RNDR) for the first time on a Single electron Sensitive Readout (SiSeRO) device. SiSeRO is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors, developed at MIT Lincoln Laboratory. This technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. RNDR was realized by transferring the signal charge non-destructively between the internal gate and the summing well (SW), which is the last serial register. The advantage of the non-destructive charge transfer is that the signal charge for each pixel can be measured at the end of each transfer cycle and by averaging for a large number of measurements ($\mathrm{N_{cycle}}$), the total noise can be reduced by a factor of 1/$\mathrm{\sqrt{N_{cycle}}}$. In our experiments with a prototype SiSeRO device, we implemented nine ($\mathrm{N_{cycle}}$ = 9) RNDR cycles, achieving around 2 electron readout noise (equivalent noise charge or ENC) with spectral resolution close to the fano limit for silicon at 5.9 keV. These first results are extremely encouraging, demonstrating successful implementation of the RNDR technique in SiSeROs. They also lay foundation for future experiments with more optimized test stands (better temperature control, larger number of RNDR cycles, RNDR-optimized SiSeRO devices) which should be capable of achieving sub-electron noise sensitivities. This new device class presents an exciting technology for next generation astronomical X-ray telescopes requiring very low-noise spectroscopic imagers. The sub-electron sensitivity also adds the capability to conduct in-situ absolute calibration, enabling unprecedented characterization of the low energy instrument response.

astro-ph.IM↗

High hard X-ray polarization in Cygnus X-1 confined to the intermediate hard state: evidence for a variable jet component

Cygnus X-1, the well-known accreting black hole system, exhibits several observational features hinting at an intricate interplay between the accretion disk, its atmosphere known as the corona and the putative relativistic jet. It has been extensively studied using all available observational methods, including using the newly available technique of sensitive X-ray polarimetry. X-ray polarization characteristics are distinct for coronal and jet emissions. The low X-ray polarization measured below $\sim$100 keV is understood as arising from the corona. In contrast, the high polarization measurements reported above $\sim$400 keV required a separate jet-dominated spectral component, which spectroscopy does not demonstrate conclusively. Here we report precise polarization measurements in the 100-380 keV region made during three different sub-classes of spectral states of the source using the CZTI instrument onboard {\em AstroSat}. A high polarization (23$\pm$4 \%) is found mainly in the Intermediate Hard State of the source, and the energy-resolved measurements smoothly connect the coronal and the jet regimes. When high polarization is observed, the simultaneous spectral data hints at a separate power law component above 100 keV. We examine the possible sources of this energy-dependent high polarization in Cygnus X-1.

astro-ph.HE↗

The high-speed X-ray camera on AXIS

AXIS is a Probe-class mission concept that will provide high-throughput, high-spatial-resolution X-ray spectral imaging, enabling transformative studies of high-energy astrophysical phenomena. To take advantage of the advanced optics and avoid photon pile-up, the AXIS focal plane requires detectors with readout rates at least 20 times faster than previous soft X-ray imaging spectrometers flying aboard missions such as Chandra and Suzaku, while retaining the low noise, excellent spectral performance, and low power requirements of those instruments. We present the design of the AXIS high-speed X-ray camera, which baselines large-format MIT Lincoln Laboratory CCDs employing low-noise pJFET output amplifiers and a single-layer polysilicon gate structure that allows fast, low-power clocking. These detectors are combined with an integrated high-speed, low-noise ASIC readout chip from Stanford University that provides better performance than conventional discrete solutions at a fraction of their power consumption and footprint. Our complementary front-end electronics concept employs state of the art digital video waveform capture and advanced signal processing to deliver low noise at high speed. We review the current performance of this technology, highlighting recent improvements on prototype devices that achieve excellent noise characteristics at the required readout rate. We present measurements of the CCD spectral response across the AXIS energy band, augmenting lab measurements with detector simulations that help us understand sources of charge loss and evaluate the quality of the CCD backside passivation technique. We show that our technology is on a path that will meet our requirements and enable AXIS to achieve world-class science.

astro-ph.IM↗

Improved noise performance from the next-generation buried-channel p-Mosfet SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. We have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

astro-ph.IM↗

Experimental verification of off-axis polarimetry with Cadmium Zinc Telluride detectors of AstroSat-CZT Imager

The Cadmium Zinc Telluride Imager (CZTI) onboard AstroSat consists of an array of a large number of pixellated CZT detectors capable of measuring the polarization of incident hard X-rays. The polarization measurement capability of CZTI for on-axis sources was experimentally confirmed before the launch. CZTI has yielded tantalizing results on the X-ray polarization of the Crab nebula and pulsar in the energy range of 100 - 380 keV. CZTI has also contributed to the measurement of prompt emission polarization for several Gamma-Ray Bursts (GRBs). However, polarization measurements of off-axis sources like GRBs are challenging. It is vital to experimentally calibrate the CZTI sensitivity to off-axis sources to enhance the credence of the measurements. In this context, we report the verification of the off-axis polarimetric capability of pixellated CZT detectors through the controlled experiments carried out with a CZT detector similar to that used in CZTI and extensive Geant4 simulations of the experimental set-up. Our current results show that the CZT detectors can be used to measure the polarization of bright GRBs up to off-axis angles of ~60 degrees. However, at incidence angles between 45-60 degrees, there might be some systematic effects which needs to be taken into account while interpreting the measured polarisation fraction.

astro-ph.IM↗

Extending the energy range of AstroSat-CZTI up to 380 keV with Compton Spectroscopy

The CZTI (Cadmium Zinc Telluride Imager) onboard AstroSat is a high energy coded mask imager and spectrometer in the energy range of 20 - 100 keV. Above 100 keV, the dominance of Compton scattering cross-section in CZTI results in a significant number of 2-pixel Compton events and these have been successfully utilized for polarization analysis of Crab pulsar and nebula (and transients like Gamma-ray bursts) in 100 - 380 keV. These 2-pixel Compton events can also be used to extend the spectroscopic energy range of CZTI up to 380 keV for bright sources. However, unlike the spectroscopy in primary energy range, where simultaneous background measurement is available from masked pixels, Compton spectroscopy requires blank sky observation for background measurement. Background subtraction, in this case, is non-trivial because of the presence of both short-term and long-term temporal variations in the data, which depend on multiple factors like earth rotation and the effect of South Atlantic Anomaly (SAA) regions etc. We have developed a methodology of background selection and subtraction that takes into account for these effects. Here, we describe these background selection and subtraction techniques and validate them using spectroscopy of Crab in the extended energy range of 30 - 380 keV region, and compare the obtained spectral parameters with the INTEGRAL results. This new capability allows for the extension of the energy range of AstroSat spectroscopy and will also enable the simultaneous spectro-polarimetric study of other bright sources like Cygnus X-1.

astro-ph.IM↗

Single electron Sensitive Readout (SiSeRO) X-ray detectors: Technological progress and characterization

Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. Characterization was performed for a number of prototype sensors with different device architectures, e.g. location of the internal gate, MOSFET polysilicon gate structure, and location of the trough in the internal gate with respect to the source and drain of the MOSFET (the trough is introduced to confine the charge in the internal gate). Using a buried-channel SiSeRO, we have achieved a charge/current conversion gain of >700 pA per electron, an equivalent noise charge (ENC) of around 6 electrons root mean square (RMS), and a full width half maximum (FWHM) of approximately 140 eV at 5.9 keV at a readout speed of 625 Kpixel/s. In this paper, we discuss the SiSeRO working principle, the readout module developed at Stanford, and the characterization test results of the SiSeRO prototypes. We also discuss the potential to implement Repetitive Non-Destructive Readout (RNDR) with these devices and the preliminary results which can in principle yield sub-electron ENC performance. Additional measurements and detailed device simulations will be essential to mature the SiSeRO technology. However, this new device class presents an exciting technology for next generation astronomical X-ray telescopes requiring fast, low-noise, radiation hard megapixel imagers with moderate spectroscopic resolution.

astro-ph.IM↗

Hard X-ray polarization catalog for a 5-year sample of Gamma-Ray Bursts using AstroSat CZT-Imager

Cadmium Zinc Telluride Imager (CZTI) aboard AstroSat has been regularly detecting Gamma-Ray Bursts (GRBs) since its launch in 2015. Its sensitivity to polarization measurements at energies above 100 keV allows CZTI to attempt spectro-polarimetric studies of GRBs. Here, we present the first catalog of GRB polarization measurements made by CZTI during its first five years of operation. This presents the time integrated polarization measurements of the prompt emission of 20 GRBs in the energy range 100-600 keV. The sample includes the bright GRBs which were detected within an angle range of 0-60 degree and 120-180 degree where the instrument has useful polarization sensitivity and is less prone to systematics. We implement a few new modifications in the analysis to enhance polarimetric sensitivity of the instrument. Majority of the GRBs in the sample are found to possess less / null polarization across the total bursts' duration in contrast to a small fraction of five GRBs exhibiting high polarization. The low polarization across the bursts can be speculated to be either due to the burst being intrinsically weakly polarized or due to varying polarization angle within the burst even when it is highly polarized. In comparison to POLAR measurements, CZTI has detected a larger number of cases with high polarization. This may be a consequence of the higher energy window of CZTI observations which results in the sampling of smaller duration of burst emissions in contrast to POLAR, thereby, probing emissions of less temporal variations of polarization properties.

astro-ph.HE↗

Gamma-Ray Polarimetry

While the scientific potential of high-energy X-ray and gamma-ray polarimetry has long been recognized, measuring the polarization of high-energy photons is challenging. To date, there has been very few significant detections from an astrophysical source. However, recent technological developments raise the possibility that this may change in the not-too-distant future. Significant progress has been made in the development of Gamma-ray Burst (GRB) polarimeters and polarization sensitive Compton telescopes. A second-generation dedicated GRB polarimeter, POLAR-2, is under development for launch in 2024, and COSI a second-generation polarization sensitive Compton Telescope has been selected by NASA for launch in 2025. This chapter reviews basic concepts and experimental approaches of scattering polarimetry of hard X-rays to MeV γ-rays, and pair production polarimetry of higher-energy photons

astro-ph.IM↗

Development and characterization of a fast and low noise readout for the next generation X-ray CCDs

The broad energy response, low electronic read noise, and good energy resolution have made X-ray Charge-Coupled Devices (CCDs) an obvious choice for developing soft X-ray astronomical instruments over the last half century. They also come in large array formats with small pixel sizes which make them a potential candidate for the next generation astronomical X-ray missions. However, the next generation X-ray telescopic experiments propose for significantly larger collecting area compared to the existing observatories in order to explore the low luminosity and high redshift X-ray universe which requires these detectors to have an order of magnitude faster readout. In this context, the Stanford University (SU) in collaboration with the Massachusetts Institute of Technology (MIT) has initiated the development of fast readout electronics for X-ray CCDs. At SU, we have designed and developed a fast and low noise readout module with the goal of achieving a readout speed of 5 Mpixel/s. We successfully ran a prototype CCD matrix of 512 $\times$ 512 pixels at 4 Mpixels/s. In this paper, we describe the details of the readout electronics and report the performance of the detectors at these readout speeds in terms of read noise and energy resolution. In the future, we plan to continue to improve performance of the readout module and eventually converge to a dedicated ASIC based readout system to enable parallel read out of large array multi-node CCD devices.

astro-ph.IM↗

First results on SiSeRO (Single electron Sensitive Read Out) devices -- a new X-ray detector for scientific instrumentation

We present an evaluation of a novel on-chip charge detector, called the Single electron Sensitive Read Out (SiSeRO), for charge-coupled device (CCD) image sensor applications. It uses a p-MOSFET transistor at the output stage with a depleted internal gate beneath the p-MOSFET. Charge transferred to the internal gate modulates the source-drain current of the transistor. We have developed a drain current readout module to characterize the detector. The prototype sensor achieves a charge/current conversion gain of 700 pA per electron, an equivalent noise charge (ENC) of 15 electrons (e-) root mean square (RMS), and a full width half maximum (FWHM) of 230 eV at 5.9 keV. In this paper, we discuss the SiSeRO working principle, the readout module developed at Stanford, and the first characterization test results of the SiSeRO prototypes. While at present only a proof-of-concept experiment, in the near future we plan to use next generation sensors with improved noise performance and an enhanced readout module. In particular, we are developing a readout module enabling Repetitive Non-Destructive Readout (RNDR) of the charge, which can in principle yield sub-electron ENC performance. With these developments, we eventually plan to build a matrix of SiSeRO amplifiers to develop an active pixel sensor with an on-chip ASIC-based readout system. Such a system, with fast readout speeds and sub-electron noise, could be effectively utilized in scientific applications requiring fast and low-noise spectro-imagers.

astro-ph.IM↗

The AstroSat Mass Model: Imaging and Flux studies of off-axis sources with CZTI

The Cadmium Zinc Telluride Imager (CZTI) on AstroSat is a hard X-ray coded-aperture mask instrument with a primary field of view of 4.6 x 4.6 degrees (FWHM). The instrument collimators become increasingly transparent at energies above $\sim$100 keV, making CZTI sensitive to radiation from the entire sky. While this has enabled CZTI to detect a large number of off-axis transient sources, calculating the source flux or spectrum requires knowledge of the direction and energy dependent attenuation of the radiation incident upon the detector. Here, we present a GEANT4-based mass model of CZTI and AstroSat that can be used to simulate the satellite response to the incident radiation, and to calculate an effective "response file" for converting the source counts into fluxes and spectra. We provide details of the geometry and interaction physics, and validate the model by comparing the simulations of imaging and flux studies with observations. Spectroscopic validation of the mass model is discussed in a companion paper, Chattopadhyay 2021.

astro-ph.IM↗

Hard X-ray Polarimetry -- An overview of the method, science drivers and recent findings

The last decade has seen a leapfrog in the interest in X-ray polarimetry with a number of new polarization measurements in hard X-rays from AstroSat, POLAR, GAP, and PoGO+. The measurements provide some interesting insights into various astrophysical phenomena such as coronal geometry and disk-jet connection in black hole X-ray binaries, hard X-ray emission mechanism in pulsars and Gamma Ray Bursts (GRB). They also highlight an increase in polarization with energy which makes hard X-ray polarimetry extremely appealing. There is a number of confirmed hard X-ray polarimetry experiments which along with the existing instruments (AstroSat and INTEGRAL) makes this field further exciting. Polarization experiments may also see a significant progress in sensitivity with new developments in scintillator readouts, active pixel sensors, CZT detectors. In particular, the advent of hard X-ray focusing optics, will enable designing of compact focal plane polarimeters with a multifold enhancement in sensitivity. In this review, we will focus on the recent polarimetry findings, science potential of hard X-ray polarimetry along with possible improvements in the measurement techniques.

astro-ph.HE↗