SearcharxivSearch

arXiv subjects

Tatiana Novikova

Publications and source records attributed to Tatiana Novikova.

11 recordsLinked to original sources

Gestational Stage Prediction from Cervical Tissue Analysis Using Imaging Mueller Polarimetry Data

Preterm birth is associated with premature cervical remodeling, yet current clinical assessments cannot detect the underlying microstructural changes in collagen organization. We apply imaging Mueller polarimetry to murine cervical tissue at three gestational stages (early, mid, late) and develop classification methods to predict gestational stage from polarimetric maps. Using Lu-Chipman decomposition, we extract orientation and azimuth local variability maps that capture collagen fiber alignment and disorder. We evaluate two approaches under 20-fold leave-one-out cross-validation: an analytical threshold classifier on mean azimuth local variability, and a lightweight CNN ensemble (approximately 76k parameters) operating on spatially resolved maps. The ensemble achieves 70..0% sample-level accuracy, outperforming the analytical baseline (55.0%), with strong performance on early (71.0%) and late (86.0%) gestation. Spatial prediction maps confirm that classification accuracy is highest in the stroma, where collagen remodeling is most prominent. These results demonstrate that Mueller polarimetry combined with deep learning models can detect gestational collagen remodeling noninvasively, offering a potential pathway toward objective cervical assessment for preterm birth risk.

physics.med-ph

Intensity-based Segmentation of Tissue Images Using a U-Net with a Pretrained ResNet-34 Encoder: Application to Mueller Microscopy

Manual annotation of the images of thin tissue sections remains a time-consuming step in Mueller microscopy and limits its scalability. We present a novel automated approach using only the total intensity M11 element of the Mueller matrix as an input to a U-Net architecture with a pretrained ResNet-34 encoder. The network was trained to distinguish four classes in the images of murine uterine cervix sections: background, internal os, cervical tissue, and vaginal wall. With only 70 cervical tissue sections, the model achieved 89.71% pixel accuracy and 80.96% mean tissue Dice coefficient on the held-out test dataset. Transfer learning from ImageNet enables accurate segmentation despite limited size of training dataset typical of specialized biomedical imaging. This intensity-based framework requires minimal preprocessing and is readily extensible to other imaging modalities and tissue types, with publicly available graphical annotation tools for practical deployment.

eess.IV

Physically Consistent Image Augmentation for Deep Learning in Mueller Matrix Polarimetry

Mueller matrix polarimetry captures essential information about polarized light interactions with a sample, presenting unique challenges for data augmentation in deep learning due to its distinct structure. While augmentations are an effective and affordable way to enhance dataset diversity and reduce overfitting, standard transformations like rotations and flips do not preserve the polarization properties in Mueller matrix images. To this end, we introduce a versatile simulation framework that applies physically consistent rotations and flips to Mueller matrices, tailored to maintain polarization fidelity. Our experimental results across multiple datasets reveal that conventional augmentations can lead to falsified results when applied to polarimetric data, underscoring the necessity of our physics-based approach. In our experiments, we first compare our polarization-specific augmentations against real-world captures to validate their physical consistency. We then apply these augmentations in a semantic segmentation task, achieving substantial improvements in model generalization and performance. This study underscores the necessity of physics-informed data augmentation for polarimetric imaging in deep learning (DL), paving the way for broader adoption and more robust applications across diverse research in the field. In particular, our framework unlocks the potential of DL models for polarimetric datasets with limited sample sizes. Our code implementation is available at github.com/hahnec/polar_augment.

cs.CV

Machine Learning Model for Complete Reconstruction of Diagnostic Polarimetric Images from partial Mueller polarimetry data

The translation of imaging Mueller polarimetry to clinical practice is often hindered by large footprint and relatively slow acquisition speed of the existing instruments. Using polarization-sensitive camera as a detector may reduce instrument dimensions and allow data streaming at video rate. However, only the first three rows of a complete 4x4 Mueller matrix can be measured. To overcome this hurdle we developed a machine learning approach using sequential neural network algorithm for the reconstruction of missing elements of a Mueller matrix from the measured elements of the first three rows. The algorithm was trained and tested on the dataset of polarimetric images of various excised human tissues (uterine cervix, colon, skin, brain) acquired with two different imaging Mueller polarimeters operating in either reflection (wide-field imaging system) or transmission (microscope) configurations at different wavelengths of 550 nm and 385 nm, respectively. The reconstruction performance was evaluated using various error metrics, all of which confirmed low error values. The execution time of the trained neural network algorithm was about 300 microseconds for a single image pixel. It suggests that a machine learning approach with parallel processing of all image pixels combined with the partial Mueller polarimeter operating at video rate can effectively substitute for the complete Mueller polarimeter and produce accurate maps of depolarization, linear retardance and orientation of the optical axis of biological tissues, which can be used for medical diagnosis in clinical settings.

physics.optics

Characterization of Polarimetric Properties in Various Brain Tumor Types Using Wide-Field Imaging Mueller Polarimetry

Neuro-oncological surgery is the primary brain cancer treatment, yet it faces challenges with gliomas due to their invasiveness and the need to preserve neurological function. Hence, radical resection is often unfeasible, highlighting the importance of precise tumor margin delineation to prevent neurological deficits and improve prognosis. Imaging Mueller polarimetry, an effective modality in various organ tissues, seems a promising approach for tumor delineation in neurosurgery. To further assess its use, we characterized the polarimetric properties by analysing 45 polarimetric measurements of 27 fresh brain tumor samples, including different tumor types with a strong focus on gliomas. Our study integrates a wide-field imaging Mueller polarimetric system and a novel neuropathology protocol, correlating polarimetric and histological data for accurate tissue identification. An image processing pipeline facilitated the alignment and overlay of polarimetric images and histological masks. Variations in depolarization values were observed for grey and white matter of brain tumor tissue, while differences in linear retardance were seen only within white matter of brain tumor tissue. Notably, we identified pronounced optical axis azimuth randomization within tumor regions. This study lays the foundation for machine learning-based brain tumor segmentation algorithms using polarimetric data, facilitating intraoperative diagnosis and decision making.

physics.med-ph

Near-Real-Time Mueller Polarimetric Image Processing for Neurosurgical Intervention

Wide-field imaging Mueller polarimetry is a revolutionary, label-free, and non-invasive modality for computer-aided intervention: in neurosurgery it aims to provide visual feedback of white matter fibre bundle orientation from derived parameters. Conventionally, robust polarimetric parameters are estimated after averaging multiple measurements of intensity for each pair of probing and detected polarised light. Long multi-shot averaging, however, is not compatible with real-time in-vivo imaging, and the current performance of polarimetric data processing hinders the translation to clinical practice. A learning-based denoising framework is tailored for fast, single-shot, noisy acquisitions of polarimetric intensities. Also, performance-optimised image processing tools are devised for the derivation of clinically relevant parameters. The combination recovers accurate polarimetric parameters from fast acquisitions with near-real-time performance, under the assumption of pseudo-Gaussian polarimetric acquisition noise. The denoising framework is trained, validated, and tested on experimental data comprising tumour-free and diseased human brain samples in different conditions. Accuracy and image quality indices showed significant improvements on testing data for a fast single-pass denoising versus the state-of-the-art and high polarimetric image quality standards. The computational time is reported for the end-to-end processing. The end-to-end image processing achieved real-time performance for a localised field of view. The denoised polarimetric intensities produced visibly clear directional patterns of neuronal fibre tracts in line with reference polarimetric image quality standards; directional disruption was kept in case of neoplastic lesions. The presented advances pave the way towards feasible oncological neurosurgical translations of novel, label free, interventional feedback.

eess.IV

Time-efficient filtering of polarimetric data by checking physical realizability of experimental Mueller matrices

Imaging Mueller polarimetry has already proved its potential for metrology, remote sensing and biomedicine. The real-time applications of this modality require both video rate image acquisition and fast data post-processing algorithms. First, one must check the physical realizability of the experimental Mueller matrices in order to filter out non-physical data, i.e. to test the positive semi-definiteness of the 4x4 Hermitian coherency matrix calculated from the elements of the corresponding Mueller matrix pixel-wise. For this purpose, we compared the execution time for the calculations of i) eigenvalues, ii) Cholesky decomposition, iii) Sylvester's criterion, and iv) coefficients of the characteristic polynomial of the Hermitian coherency matrix using two different approaches, all calculated for the experimental Mueller matrix images (600 pixels x 700 pixels) of mouse uterine cervix. The calculations were performed using C++ and Julia programming languages. Our results showed the superiority of the algorithm iv), in particular, the version based on the simplification via Pauli matrices, in terms of execution time for our dataset, over other algorithms. The sequential implementation of the latter algorithm on a single core already satisfies the requirements of real-time polarimetric imaging in various domains. This can be further amplified by the proposed parallelization (for example, we achieve a 5-fold speed up on 6 cores).

physics.optics

Wide-Field Mueller Polarimetry of Brain Tissue Sections for Visualization of White Matter Fiber Tracts

Identification of white matter fiber tracts of the brain is crucial for delineating the tumor border during neurosurgery. A custom-built Mueller polarimeter was used in reflection configuration for the wide-field imaging of thick section of fixed human brain and fresh calf brain. The experimental images of azimuth of the fast optical axis of linear birefringent medium showed a strong correlation with the silver-stained sample histology image, which is the gold standard for ex-vivo brain fiber tract visualization. The polarimetric images of fresh calf brain tissue demonstrated the same trends in depolarization, scalar retardance and azimuth of the fast optical axis as seen in fixed human brain tissue. Thus, label-free imaging Mueller polarimetry shows promise as an efficient intra-operative modality for the visualization of healthy brain white matter fiber tracts, which could improve the accuracy of tumor border detection and, ultimately, patient outcomes.

physics.med-ph

Impact of charged species transport coefficients on self-bias voltage in an electrically asymmetric RF discharge

In this paper, we use a fluid model to simulate the excitation of a hydrogen radio-frequency discharge, and employ tailored voltage waveforms to assess the effect of charged species transport properties. Results of the fluid simulation are compared with experimental data and previous results obtained with a hybrid model. Several expressions for electron and ion transport coefficients are compared, and their impact on the self-bias potential is studied. The self-bias is shown to be insensitive to the choice of electron transport coefficients, while remarkably sensitive to variations in ion mobility. Besides, our results show that fluid models can be competitive with hybrid models, provided self-consistent ion transport models and rate constants are used.

physics.plasm-ph

Data Integration for Supporting Biomedical Knowledge Graph Creation at Large-Scale

In recent years, following FAIR and open data principles, the number of available big data including biomedical data has been increased exponentially. In order to extract knowledge, these data should be curated, integrated, and semantically described. Accordingly, several semantic integration techniques have been developed; albeit effective, they may suffer from scalability in terms of different properties of big data. Even scaled-up approaches may be highly costly because tasks of semantification, curation and integration are performed independently. In order to overcome these issues, we devise ConMap, a semantic integration approach which exploits knowledge encoded in ontology in order to describe mapping rules to perform these tasks at the same time. Experimental results performed on different data sets suggest that ConMap can significantly reduce the time required for knowledge graph creation by up to 70\% of the time that is consumed following a traditional approach.

cs.DB

Kinetic theory of two-temperature polyatomic plasmas

We investigate the kinetic theory of two-temperature plasmas for reactive polyatomic gas mixtures. The Knudsen number is taken proportional to the square root of the mass ratio between electrons and heavy-species, and thermal non-equilibrium between electrons and heavy species is allowed. The kinetic non-equilibrium framework also requires a weak coupling between electrons and internal energy modes of heavy species. The zeroth-order and first-order fluid equations are derived by using a generalized Chapman-Enskog method. Expressions for transport fluxes are obtained in terms of macroscopic variable gradients and the corresponding transport coefficients are expressed as bracket products of species perturbed distribution functions. The theory derived in this paper provides a consistent fluid model for non-thermal multicomponent plasmas.

physics.plasm-ph