SearcharxivSearch

arXiv subjects

Tatsat Parekh

Publications and source records attributed to Tatsat Parekh.

2 recordsLinked to original sources

Optical Design of the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

This work describes the design and implementation of optics for EXCLAIM, the EXperiment for Cryogenic Large-Aperture Intensity Mapping. EXCLAIM is a balloon-borne telescope that will measure integrated line emission from carbon monoxide (CO) at redshifts $z<1$ and ionized carbon ([CII]) at redshifts $z = 2.5-3.5$ to probe star formation over cosmic time in cross-correlation with galaxy redshift surveys. The EXCLAIM instrument is designed to observe at frequencies of $420$--$540$ GHz using six microfabricated silicon integrated spectrometers with spectral resolving power $R = 512$ coupled to kinetic inductance detectors (KIDs). A completely cryogenic telescope cooled to a temperature below 5~K provides low-background observations between narrow atmospheric lines in the stratosphere. Off-axis reflective optics use a $90$-cm primary mirror to provide $4.2^\prime$ full-width at half-maximum (FWHM) resolution at the center of the EXCLAIM band over a field of view of $22.5^\prime$. Illumination of the $1.7$ K cold stop combined with blackened baffling at multiple places in the optical system ensure low ($< -40$ dB) edge illumination of the primary to minimize spill onto warmer elements at the top of the dewar.

astro-ph.IM

Superfluid-tight cryogenic receiver with continuous sub-Kelvin cooling for EXCLAIM

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 - 540 GHz frequency range. EXCLAIM uses a fully cryogenic telescope coupled to six on-chip spectrometers featuring kinetic inductance detectors (KIDs) to achieve high sensitivity, allowing for fast integration in dark atmospheric windows. The telescope receiver is cooled to $\approx$ 1.7 K by immersion in a superfluid helium bath and enclosed in a superfluid-tight shell with a meta-material anti-reflection coated silicon window. In addition to the optics and the spectrometer package, the receiver contains the magnetic shielding, the cryogenic segment of the spectrometer readout, and the sub-Kelvin cooling system. A three-stage continuous adiabatic demagnetization refrigerator (CADR) keeps the detectors at 100 mK while a $^4$He sorption cooler provides a 900 mK thermal intercept for mechanical suspensions and coaxial cables. We present the design of the EXCLAIM receiver and report on the flight-like testing of major receiver components, including the superfluid-tight receiver window and the sub-Kelvin coolers.

astro-ph.IM