SearcharxivSearch

arXiv subjects

Tatsat R. Patel

Publications and source records attributed to Tatsat R. Patel.

2 recordsLinked to original sources

Cerebral Aneurysm Flow Diverter Modeled as a Thin Inhomogeneous Porous Medium in Hemodynamic Simulations

Rapid and accurate simulation of cerebral aneurysm flow modifications by flow diverters (FDs) can help improving patient-specific intervention and predicting treatment outcome. However, with explicit FD devices being placed in patient-specific aneurysm model, the computational domain must be resolved around the thin stent wires, leading to high computational cost in computational fluid dynamics (CFD). Classic homogeneous porous medium (PM) methods cannot accurately predict the post-stenting aneurysmal flow field due to the inhomogeneous FD wire distributions on anatomic arteries. We propose a novel approach that models the FD flow modification as a thin inhomogeneous porous medium (iPM). It improves over classic PM approaches in that, first, FD is treated as a screen, which is more accurate than the classic Darcy-Forchheimer relation based on 3D PM. second, the pressure drop is calculated using local FD geometric parameters across an inhomogeneous PM, which is more realistic. To test its accuracy and speed, we applied the iPM technique to simulate the post stenting flow field in three patient-specific aneurysms and compared the results against CFD simulations with explicit FD devices. The iPM CFD ran 500% faster than the explicit CFD while achieving 94%-99% accuracy. Thus iPM is a promising clinical bedside modeling tool to assist endovascular interventions with FD and stents.

physics.flu-dyn

A hybrid echocardiography-computational fluid dynamics framework for ventricular flow simulations

Image-based computational fluid dynamics (CFD) has emerged as a powerful tool to study cardiovascular flows while 2D echocardiography (echo) is the most widely used non-invasive imaging modality for diagnosis of heart disease. Here, echo is combined with CFD, i.e., an echo-CFD framework, to study ventricular flows. To achieve this, our previous 3D reconstruction from multiple 2D-echo at standard cross-sections is extended by 1) reconstructing valves (aortic and mitral valves) from 2D-echo images and the superior wall; 2) optimizing the location and orientation of the surfaces to incorporate the physiological assumption of fixed apex as a reference (fixed) point for reconstruction; and 3) incorporating several smoothing algorithms to remove the nonphysical oscillations (ringing) near the basal section observed in our previous study. The main parameters of the reconstructed left ventricle (LV) are all within the physiologic range. Our results show that the mitral valve can significantly change the flow pattern inside the LV during the diastole phase in terms of ring vortex formation/propagation as well as the flow circulation. In addition, the abnormal shape of unhealthy LV can drastically change the flow field during the diastole phase. Furthermore, the hemodynamic energy loss, as an indicator of the LV pumping performance, for different test cases is calculated which shows a larger energy loss for unhealthy LV compared to the healthy one.

physics.flu-dyn